ZN210/220 flange mounted differential pressure transmitter
Product details

The ZN210/220 flange mounted differential pressure transmitter adopts single crystal silicon resonant sensor technology, which minimizes the effects of overvoltage, temperature changes, and static pressure, providing unparalleled long-term stability. Fieldbus is a bidirectional digital communication system, an innovative technology for configuring instrument control systems, and also a promising replacement product for the widely used standard 4-20mA analog communication in field instruments.
The JT series offers two fieldbus modes, FOUNDATION fieldbus low voltage mode and PROFIBUS PA equipment, to achieve collaborative work between Yokogawa Electric and other suppliers. In terms of software, the JT series uses two AI function blocks to calculate differential pressure and static pressure, thereby achieving flexible instrument configuration.

specifications

ZN210A / 220A
Flange mounted differential pressure transmitter
M membrane box H membrane box
Measurement range -100~100kPa
(-400~400inH2O) -500~500kPa
(-2000~2000inH2O)
Measurement range 1-100kPa
(4~400inH2O) 5~500kPa
(20~2000inH2O)
Accuracy ± 0.2222% ± 0.2222%
Protection level IP67, NEMA 4X, And JIS C0920 immersion proof type
Explosion proof specification FM, CENELEC ATEX,CSA,IECEx
Output signal 4-20mA DC or FOUNDATION? Fieldbus or PROFIBUS PA two-wire digital communication
Power supply BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)
Environmental temperature -40~85 ℃ (-40~185 ℉) (ordinary type)
-30~80 ℃ (-22~176 ℉) (with built-in indicator)
Process temperature -40~120 ℃ (-40~248 ℉) (ordinary type)
Maximum working pressure flange rated pressure
Install flange installation
Flange size

ZN210A: 3-inch (80mm),2-inch (50mm)
ZN220A: 4-inch (100mm),3-inch (80mm)
DIAPHRAGM MATERIAL
(High voltage side) SUS316L, Hastelloy C-276, Tantalum material
Flange material S25C, SUS304,SUS316
Aluminum alloy or SUS316 stainless steel shell (optional)

Selection Table for Flange Mounted Differential Pressure Transmitters

Item 1

Output signal - D 4-20mA DC/BRAN protocol digital communication
-E 4-20mA DC/HART protocol digital communication
-F FF fieldbus communication

Item 2

Measurement range (capsule) M 1-100KPa
H 5-500KPa

Item 3

High pressure side (flange side) liquid contact material S JIS SUS316L JIS SUS316 JIS SUS316
W Hastelloy C-276 JIS SUS316 JIS SUS316

Item 4

Flange specification J1 JIS 10K
J2 JIS 20K
A1 ANSI150
A2 ANSI300
P1 JPI150
P2 JPI300
D2 DIN PN10/16
D4 DIN PN25/40
G2 GB PN10/16
G4 GB PN25/40

Item 5

Diaphragm protrusion length (X2) 2 X2=50mm
4 X2=100mm
6 X2=150mm

Item 6

Flange size/material G 100mm (4 ")/JIS S25C
H 100mm(4")/JIS SUS304
J 100mm(4")/JIS SUS316
D 80mm(3")/JIS S25C
E 80mm(3")/JIS SUS304
F 80mm(3")/JIS SUS316

Item 7

Low pressure side process interface 0 has no process joint (Rc1/4 internal thread on the chamber flange)
1 Rc1/4 internal thread process joint
2 Rc1/2 internal thread process joint
3 1/4NPT internal thread process joint
4 1/2NPT internal thread process joint
5. No process joint (1/4NPT internal thread on the chamber flange)

Item 8

Bolt and nut material A JIS SCM435
B JIS SUS630
C JIS SUH660

Item 9

Installation Method -9
Horizontal piping connection, high pressure on the left side

Item 10

Electrical interface 0 G1/2 internal thread, one electrical interface
2 1/2NPT internal thread, two electrical interfaces, no blind plugs
3 Pg13.5 internal threads, two electrical interfaces, no blind plugs
4 M20 internal thread, two electrical interfaces, no blind plugs
5 G1/2 internal thread, two electrical interfaces, one blind plug
7 1/2NPT internal thread, two electrical interfaces, one blind plug
8 Pg13.5 internal thread, two electrical interfaces, one blind plug
9 M20 internal thread, two electrical interfaces, one blind plug

Item 11

Hidden Display Table D Digital Display Table
E digital display strap measurement range setting button
N None

Item 12

- N
Always for N


Additional functions of flange mounted differential pressure transmitter

Item 1

Explosion proof and intrinsic safety types are not specified
NF1 NEPSI Explosion proof License: d Ⅱ CT6 Environmental Temperature: -40-60 ℃ Electrical Interface: 1/2NPT
FF1 FM Explosion proof Permit C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1:T6
FF15 FM Explosion proof License C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1:T6
KF1 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4 T5、T6
KF5 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4 T5、T6
CF1 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI:T4、T5、T6
CF15 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI:T4、T5、T6
NS1 NEPSI intrinsic safety license: ia Ⅱ CT4 environmental temperature: -40-60 ℃ electrical interface: 1/2NPT
FS1 FM intrinsic safety license intrinsic safety C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G non combustible C1: I-II&III Div, 1&2 Gps、B、C、D、E、F&G
KS1 CENELEC (KEMA) intrinsic safety license: EEx ia Ⅱ CT4
CS1 CSA intrinsic safety license: C1: I-II&III Div, 1&2, Gps, A, B, C, D, E, F&G ENCL: Type4X Temperature C1: T4
FU1 includes FF1 and FS1
KU1 includes KF1.KS1 and N-type KEMA, N-type EX nA Ⅱ CT4
CU1 includes CF1 and CS1
SU1 SAA explosion-proof and intrinsically safe with spark free Ex d Ⅱ CT6/T5/T4 IP67, Ex ia Ⅱ CT4 IP67, Ex n Ⅱ CT4 IP67
KS5 CENELEC (KEMA) intrinsic safety explosion-proof: [Entity mode]: EEx ia Ⅱ CT4; [Fisco mode]: EEx ia Ⅱ CT4/EEx ia Ⅱ BT4

Item 2

Explosion proof sealing joint not specified
G71 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (1 piece)
G72 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (1 piece)
G81 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (2 pieces)
G82 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (2 pieces)

Item 3

Painting: Color change or painting change not specified
P1 color change only applies to the transmitter housing Munsell symbol code: N1.5, black
The P2 color change is only applicable to the transmitter housing Munsell logo code: 7.5BG4/1.5 green
P7 color change only applies to transmitter housing metal silver
X1 Painting Change Epoxy Resin Baking

Item 4

Lightning protection device not specified
A transmitter power supply voltage: 10.5-32V DC (intrinsic safety type: 10.5-30V DC) Maximum allowable current: 6000A (1X4 μ S), repeated 1000A (1X40 μ S) 100 times

Item 5

Prohibition of oil treatment or prohibition of water and oil treatment not specified
K1 degreasing and cleaning treatment
K2 degreasing and cleaning treatment, and the membrane box is filled with fluorine oil, with a usage temperature of -20-80 ℃
K5 degreasing, washing and drying treatment
K6 degreasing, cleaning, and drying treatment membrane box filled with fluorine oil, operating temperature -20-80 ℃

Item 6

Calibration unit not specified
D1 P correction (Psi unit)
D3 bar calibration (in bar units)
D4 M correction (kgf/cm2)

Item 7

The sealing treatment of SUS630 nuts is not specified
Surface coating of SUS630 bolts and nuts for Y fastening chamber flange (liquid silicone rubber)

Item 8

Non serrated shape not specified
Q flange sealing surface does not undergo serrated processing (only ANSI flanges)

Item 9

Teflon film not specified
FEP PTFE film, filled with fluorine oil, working range 20-120 ℃, 0-2MPa (not suitable for vacuum state)

Item 10

Output set to low side or NAMUK NE43 unspecified when CPU exception occurs
C1 low side: ≤- 5%(3.2mA DC)
C2 (NAMUK NE43) [output signal 3.8-20.5mA] fault alarm output -5%, below 3.2mA
C3 (NAMUK NE43) [output signal 3.8-20.5mA] fault alarm output 110%, above 21.6mA

Item 11

Stainless steel amplifier housing not specified
E1 amplifier housing material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M)

Item 12

Gold plated film not specified
A1 sealing membrane gold-plated

Item 13

Quick response unspecified
F1 refresh time: ≤ 0.125 seconds response time (including minimum damping time constant): maximum 0.5 seconds

Item 14

PID/LM function not specified
LC1 PID control function, Link Master function

Item 15

Stainless steel license plate not specified
N4 JIS SUS304 stainless steel tag plate fixed on the transmitter

Item 16

Accessory manufacturing certificate not specified
M03 H: Side flange, diaphragm seat L: chamber flange
M13 H: Side flange, diaphragm seat L: chamber flange, process joint

Item 17

Pressure test/leak test certificate not specified
T31 JIS 10K test pressure: 2MPa test fluid nitrogen retention time 10 minutes
T32 JIS 20K Test Pressure: 5MPa Test Fluid Nitrogen Retention Time: 10 minutes
T36 ANSI/JPI 150 Test Pressure: 3MPa Test Fluid Nitrogen Retention Time 10 minutes