Zhejiang Hongyuan Automation Instrument Co., Ltd
Home>Products>ZJHPF46 Pneumatic Bellows lined Fluorine Regulating Valve
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 18 Xihua Road, Luqiao, Oubei, Wenzhou City, Zhejiang Province
Contact Now
ZJHPF46 Pneumatic Bellows lined Fluorine Regulating Valve
Product Model: ZJHPF46 Product Features: ZJHPF46 Pneumatic Bellows lined Fluorine Regulating Valve
Product details

ZJHPF46 Pneumatic Bellows lined Fluorine Regulating Valve

Type Straight through single seat cast ball valve
Nominal Diameter 20. 25, 32, 40, 50, 65, 80, 100, 125, 150, 200mm
nominal pressure PN1.6、4.0、6.4MPa
Flange standard JB/T79.1-94、 79.2-94, etc
Material Science Cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti), etc
Upper valve cover Standard Type -17~+230 ℃, Heat Dissipation Type+230~+450 ℃, Low Temperature Type -60~-196 ℃, Bellows Sealed Type -40~+350 ℃
Cover type Bolt compression type
Packing material V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos textile packing, graphite packing
structural style (See Figures 1-5 for details)
Regulating valve internal components SPOOL TYPE
Single seat plunger type valve core Traffic characteristics
Equal percentage characteristic and linear characteristic


Materials: Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 17-4PH, 9Cr18, 316L), stainless steel overlay with Stellite alloy.
actuator Type
ZHA/B multi spring membrane actuator Model ZHA/B-22 ZHA/B-23 ZHAB-34 ZHA/B-45
ZHA/B-562 350 350 560 900 1400
Effective area cm Travel distance mm 25 40 10. 16 100
40, 60 Spring range KPa
20-100 (standard), 20-60, 60-100, 40-200, 80-240 Membrane material
Nitrile rubber with nylon cloth, ethylene propylene rubber with nylon cloth air supply pressure
140~400KPa air connection
RC1/4' ambient temperature
-30~+70℃
mode of action
Gas closed type (B) - valve position open when gas is lost (FO); Pneumatic opening (K) - valve position closed in case of gas loss (FC)
Control valve accessories


Positioner, air filter pressure reducer, holding valve, travel switch, valve position transmitter, handwheel mechanism, etcregulating valve
performance project Without locator
Equipped with locator Basic error% ±5.0
±1.0 Return difference% ≤3.0
≤1.0 Dead zone% ≤3.0
≤0.4 Constant point deviation% air to open Starting point ±2.5
±1.0 End ±5.0
±1.0 air to close Starting point ±5.0
±1.0 End ±2.5
±1.0 Rated travel deviation%
≤2.5 Leakage rate l/h
0.01% x valve rated capacity Adjustable range R
30:01:00
Rated flow coefficient Kv, rated stroke, and equipped actuator model of sulfuric acid regulating valve 20 25 32 40 50 65 80 100 125 150 200
Nominal diameter DN (mm) 10 12 15 20 25 32 40 50 65 80 100 125 150 200
Valve seat diameter dN (mm) Rated flow coefficient Kv 1.8 2.8 4.4 6.9 11 17.6 27.5 44 69 110 176 275 440 690
straight line 1.6 2.5 4 6.3 10 16 25 40 63 100 160 250 400 630
Equal percentage 10 16 25 40 60
Rated travel L (mm) Model of actuator ZHA/B-22 ZHA/B-23 ZHA/B-34
ZHA/B-45

Allowable tolerance 20 25 32 40 50 65 80 100 125 150 200
Nominal diameter DN (mm) 10 12 15 20 25 32 40 50 65 80 100 125 150 200
Valve seat diameter dN (mm) actuator ZHA/B22 ZHA/B 23 ZHA/B 34
ZHA/B 45 role Gas source spring
Allowable pressure difference (MPa) way pressure
range (Kpa)
(Kpa) 140 air to close 6.4 6.19 3.96 2.23 2.14 0.87 0.56 0.35 0.34 0.22 0.14 0.15 0.1 0.06
250 20~100 6.4 6.4 6.4 6.4 6.4 5.68 3.64 2.3 2.21 1.43 0.91 0.95 0.66 0.37
400 20~100 6.4 6.4 6.4 6.4 6.4 6.4 5.04 3.18 3.06 1.98 1.26 1.32 0.92 0.52
40~200 140 air to open 4.46 3.09 1.98 1.16 0.7 0.44 0.28 0.18 0.17 0.11 0.07 0.07 0.05 0.03
250 20~100 6.4 6.4 5.94 3.34 2.14 1.31 0.84 0.53 0.51 0.33 0.21 0.22 0.15 0.09
400 40~200 6.4 6.4 6.4 6.4 4.99 3.05 1.95 1.25 1.18 0.78 0.5 0.51 0.36 0.21
80~240


Note: For bellows sealed regulating valves, the maximum allowable pressure difference is 1.0 MPa. If the value in the table is less than 1.0 MPa, it remains unchanged. If it is greater than 1.0 MPa, it is taken as 1.0 MPa.

Dimensions and weight units: mm 20 25 32 40 50 65 80 100 125 150 200
Nominal diameter DN (mm) L 184 184 220 222 254 276 298 352 410 451 600
PN16/40 210 210 251 251 286 311 337 394 457 508 650
PN64 285 285 285 285 285 360 360 360 470 470 470
A H1 128 128 152 152 160 205 205 208 273 330 364
PN16/40 140 140 160 160 180 210 210 220 290 340 370
PN64 298 298 298 298 298 380 380 380 510 510 510
H2 H3 208 208 224 228 228 334 334 342 408 453 482
PN16/40 220 220 240 240 240 350 350 360 420 470 500
PN64 338 338 402 402 405 627 628 635 698 702 728
H4 H5 58 58 68 73 80 90 98 108 123 140 168
PN16/40 68 68 75 83 88 100 105 125 148 170 203
PN64 220 220 220 220 220 270 270 270 320 320 320
C 180 180 180 180 180 236 236 236 310 310 310
H6 Weight (kg) 22 22 24 32 38 62 67 83 132 160 245
PN16/40 25 25 30 42 52 78 82 102 170 190 285
PN64


Note: 1. The weight in the table is for standard models without accessories, and side mounted handwheels can also be installed.

2. The valve body flange and flange end face distance can be manufactured according to user specified standards, such as ANSI, JIS, DIN, etc. Company: mm
Model Description type Standard type Low temperature type Heat dissipation type Bellows type Jacketed insulation type Adjustment cut-off type
Fluorine lined type code not have D G W J Q
F
Ordering Notice: Please fill in the "Specification Sheet" or indicate the following content when placing an order:
1. Product model
2. Nominal pressure
3. Nominal diameter and rated flow coefficient Kv
4. Signal pressure and spring range
5. Traffic characteristics
6. Valve switching method
7. Working temperature range of the medium
8. Valve body and valve core materials
9. Is there an attachment? Please specify the attachment model


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!