ZD-2 Thunderbolt Magnetic Automatic Potentiometric Titration Instrument, ZD-2 Potentiometric Titration Instrument, ZD-2 Thunderbolt Magnetic Titration InstrumentProvided by Shanghai Shupei Experimental Equipment Co., Ltd., welcome to www.shupeilab.com
Shanghai Shupei Experimental Equipment Co., Ltd. for youProvide various laboratory instruments, forFirst level agent of the manufacturerThe company adheres to the principle ofIntegrity management,Common progressOur business philosophyThe after-sales service is complete, but there are quality issues with the product itselfFree repair, lifetime maintenanceWelcome customers to place orders.
Electrochemical analysis instrument
Conductivity meter, acidity meter, pH meter, dissolved oxygen analyzerPotentiometric titratorMoisture analyzer, electrode COD analyzer
ZD-2 Thunder Magnetic Automatic Potentiometric Titration InstrumentTechnical parameters:
Suitable for laboratory application of potentiometric titration for volumetric titration
Pre controlled potential (pH) adjustment can be performed by controlling the titration endpoint according to the set potential
Adopting electromagnetic valve to control the manual, automatic, and constant pH (potential) titration mode of the dropper
JB-1A mixer produced by our factory with a delay circuit configuration for titration endpoint
ZD-2 Thunder Magnetic Automatic Potentiometric Titration InstrumentMain technical indicators:
Instrument level: Level 0.5
1. Measurement range: pH: (0.00~14.00) pH mV: (-1400~1400) mV
2. Resolution: pH:0.01pH mV:1mV
3. Basic error: pH: ± 0.03pH ± 1 word mV: ± 0.35% FS
4. Stability: ± 0.01pH/3h
5. Input impedance: not less than 3 × 1011 Ω
6. Power supply: AC (220 ± 22) V, (50 ± 1) Hz
7. Dimensions (mm): 300 × 235 × 100
8. Instrument weight: 3kg
After sales commitment: If there is any quality problem with the product within one year, free repair and lifelong maintenance will be provided.
After sales:
Product model and name |
Technical Parameter |
Software Name |
price |
ZDJ-5Type potentiometric titrator |
Touch sensitive large LCD screen,RS232Interface, equipped with corresponding titration module for potential, conductivity, and permanent stop titration, with titration specific software; Standard configuration range:0.00~14.00pHAccuracy:±0.01pH |
Automatic titration control softwareV1.0 |
32500 |
ZDJ-5Type conductivity measurement unit |
Conductivity module: Range0.000μS/cm~ 199.9mS/cm, accuracy±1.0%FS |
|
8000 |
ZDJ-5Type permanent stop measuring unit |
Permanent stop module: Scope0~199.9)μA、0~19.99)μA、0~1.999)μA、0~0.199)μAInstrument control titration sensitivity:±5%FSPolarization current detection error:±2.5%FS |
|
6500 |
ZDJ-4Btype Automatic Potentiometric Titrator |
Large screen LCD display;Real time display of titration information and titration curve;USBandRS-232interface;conform toGLPStandardize and support the storage, retrieval, and deletion of titration curves and measurement results;Support firmware upgrade; Support factory reset. Equipped with specialized titration software; Range:0.00~14.00 pHAccuracy:±0.01 pH |
Automatic titration control softwareV1.0 |
29800 |
ZDJ-4Atype Automatic Potentiometric Titrator |
LCDDisplay, capable of multiple titrations andpHMeasurement,RS-232Interface with titration specific software; Range:0.00~14.00 pHAccuracy:±0.01 pH |
Automatic titration control softwareV1.0 |
21800 |
ZDJ-5Coulombic titrator |
Specialized Coulombic Titration, Range:0.0~±1999.9mV,Accuracy: Electrolytic current±0.25%(reading) |
Automatic titration control softwareV1.0 |
14800 |
ZD-2Type automatic potentiometric titrator |
LEDDisplay, solenoid valve controls droplet, range:0.00~14.00 pHAccuracy:±0.03pH |
Data Acquisition SoftwareV1.0 |
4980 |
ZDY-500type Automatic permanent stop titrator |
LCDDisplay reading, range:0~10)ml;0~25)ml; |
Data Acquisition SoftwareV1.0 |
3980 |
ZDY-502Type moisture titrator |
Large screen LCD display;Real time display of titration information;USBandRS-232interface;conform toGLPstandard,Support storage/View and delete;Support firmware upgrade;supportmg、mg/L、%、ppmWaiting for multiple units of measurement results;Support factory reset;Equipped with specialized titration software;range:absolute water content0.1mg~250mg,10ppm~100%H2O;resolution: 0.1mgPolarization current accuracy: ±0.2µA |
Automatic titration control softwareV1.0 |
29800 |
ZDY-501Type moisture analyzer |
Pointer reading, electric quantity method, classic method for titrating trace amounts of water, range:500µg~10mgAccuracy:±3% |
Data Acquisition SoftwareV1.0 |
3978 |
KLS-412type Trace moisture analyzer |
LCDDisplay, no membrane, Karl Fischer Coulomb method for moisture analysis, range:10μg~20mgError:±(5%Verification point+3)μ g |
Management softwareV1.0 |
9880 |
KLS-411type Trace moisture analyzer |
LCDDisplay, membrane, Karl Fischer Coulomb method for moisture analysis, range:20μg~20mgAccuracy:±3%reading |
Management softwareV1.0 |
8850 |