Xiyi Group Co., Ltd
Home>Products>YS131 indicator alarm
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
Contact Now
YS131 indicator alarm
Product Introduction: YS131 is a dual input indicator alarm. One of the two inputs can achieve upper and lower limit, upper and lower limit alarms. Pr
Product details

Product Introduction:
YS131 is a dual input indicator alarm. One of the two inputs can achieve upper and lower limit, upper and lower limit alarms.
Product Features:
Display and setting function measurement value input display: PV stick chart or trend display digital display measurement values 1 and 2 input are displayed on circuit 1 and 2 screens or trend 1 and 2 screens respectively. Parameter setting: Set on the adjustment screen and engineering screen. The alarm function is suitable for measuring input 1. Alarm types: upper limit, lower limit, upper limit, and lower limit. Alarm settings: -6.3~106.3% (can be set with engineering quantity). Set the alarm setting pointer on the trend screen. The upper and lower limit setting pointers will always display the upper and lower limits on the circuit 1 screen. The lower and upper limit setting pointers will only display when the CHG key is pressed. Lock range: 2%. Alarm display: The ALM indicator light on the front panel is on and yellow. Display on the circuit screen and alarm screen (the detailed content of the alarm is displayed on the alarm screen). When an alarm occurs, the contact output can be set to open or close (4 types of alarms can be set together). When there is a power outage, the contact output can be set to open. The contact output includes 1 upper limit, 1 lower limit, 1 upper limit, and 1 lower limit. The input signal calculation function includes a variable cutoff point. The square root calculation is performed on measurement inputs 1 and 2. It is possible to set the presence or absence of operations and the minimum cutoff point. The setting range of the minimum resection point is 0.0-100%. Trend recording specifications: Trend recording time width (within the call sign is the recording cycle): 1.5 minutes (l seconds), 7.5 minutes (5 seconds), 15 minutes (10 seconds), 45 minutes (30 seconds), 1.5 hours (l minutes), 7.5 hours (5 minutes), 15 hours (0 minutes), 45 hours (30 minutes) Trend data: 90 data meters. The front panel specification YS131 is used to switch the LCD display screen by operating the front buttons. It can be monitored and set in each screen. Page turning key; L CHG keys (for switching between upper and lower limits/upper and lower limit setting values): 1 SHIFT key (for switching between screen groups): 1 indicator light: 2 fault lights: red alarm light: yellow screen specification bar chart display scale division: maximum 10 equal scale numbers (0100% position); 6-digit engineering quantity (including decimal point, symbol) Engineering quantity unit: English numerical symbol Maximum 6-digit PV stick diagram resolution: 0.5% (200 pieces/100%) Alarm setting resolution: 0.5% PV overflow display: 100.1% or above PV overflow display: 0% or below workstation number, display of various numbers Workstation display: English numerical symbol Maximum 8-digit PV numerical display: 6-digit engineering quantity (including decimal point, symbol) Screen display specifications Screen is divided into operation screen, adjustment screen, engineering screen and other screen groups. Operation screen: Loop screen 1, Loop screen 2, Trend screen 1, Trend screen 2, Alarm screen, Dual loop screen. Adjust the screen settings screen, parameter settings screen, and input/output data screen. Engineering screen function setting screen l, function setting screen 2, function setting screen 3, direct input specification setting screen, password setting screen. Communication function, computer communication specifications, communication interface: RS-485 (5 terminals), transmission control sequence: start stop synchronization, no sequence, half duplex. Communication speed: 1200240048009600bps Connection method: Multi point connection method (up to 16 devices) Communication distance: up to 1200m Maximum frame length: 220 bytes Inter word timer: 0.1 second Communication content read and write Various parameters can be set whether data can be set through communication. YS net communication YS net can be used for communication with computers Communication specifications Communication interface: Unique YS net (2-wire) Communication speed: 75.125Kbps Connection method: Bus connection Maximum number of connected instruments: 63 (sum of YS150 and YS170) Communication distance: up to 1000m Communication cable: Twisted pair for high-speed communication with computers This function is mainly used for communication with personal computers. It can exchange data with application software with DDE service function under Windows without the need for additional programs. YS net communication specifications for personal computer side: Personal computer: IBM PC/AT and compatible YS net communication card (inserted into ISA slot) YS net communication parameter description file: YSS50 A set of communication software (DDE server, network construction software) MS Windows 3.1 or above operating system. In addition, application software with DDE server function (such as MS Excel (registered product of Microsoft Corporation) or other SCADA software) is required. Communication items: various parameters, such as measured values, set values, and operation output values. PID set values, operating modes, etc. can be sent or received. DDC or SPC mode: DDC or SPC can be selected. In DCC mode, the computer directly provides the operation output value. In SPC mode, the set value is provided by the computer. Communication exception backup: When the upper computer fails, the operation mode AUT/MAN can be set. Communication cycle: 1-second power outage recovery processing function. Choose from the following three recovery methods: TIM 1 method: hot start within about 2 seconds, about 2 seconds or more cold start. TIM 2 method: hot start within about 2 seconds, about 2 seconds or more initial start. AUT method: always hot start. After a long power outage, if the memory content is lost, it should be initially started. Parameter retention time: 48 hours or more, with an average of 7 days (capacitor retention). If the retention time has passed, the parameters written in the EEP ROM will be used. Operate the SAVE key when writing to EEPROM during operation. Parameter changes under various startup modes, self diagnostic function, abnormal operation circuit: FAIL indicator light on, fault contact output open (open during power outage), abnormal input signal: ALM indicator light, screen displaying alarm factor, screen displaying fault when machine is abnormal, screen switching to fault screen, input signal specification analog input specification analog input: 1-5V DC, 2 points 1 point can be directly input. Specify in the options. (mV, thermocouple, thermistor, sliding resistor input, input isolator, two-wire transmitter, frequency input). Input resistance: 1M Ω or above, status output signal, alarm status output signal: 4-point (upper limit, lower limit, upper upper limit, lower limit alarm), rated value of transistor contact 30VDC 200mA (resistive load), fault output signal: 1-point, rated value of transistor contact 30VDC 200mA (resistive load), signal isolation between analog input and output circuit and operation circuit are not isolated, and signal isolation is also not achieved. Negative terminal shared. The state output circuit signal is isolated from the operation circuit, and the signals are also isolated from each other. The operation circuit is isolated from the power circuit. When directly inputting, the input circuit is isolated from the computation circuit and the power supply circuit. Transmitter power supply: 24VDC 30mA (without short circuit protection) not isolated from the calculation circuit. An external 1-SV conversion resistor (250t2) and a short-circuit protection fuse are required. Standard Performance: 1-5V Signal Input Conversion Accuracy Rated Value: ± 0.2% of Range Maximum Consumption Current: 600mA (20-130VDC specification) 100mA (120-340VDC specification) Maximum Power Consumption: 26VA 100VAC (80-138VAC) 29VA 220VAC (138-264VAC) Recommended Voltage Consumption Current and Power Consumption: 430mA (24V DC) 19VA (100V AC) 23VA (22OV AC) Insulation Resistance Input/Output Terminal and Grounding Terminal: 100M Ω or more/500V DC Power Terminal and Grounding Terminal: 100M Ω or more/500V DC Voltage Endurance Input/Output Terminal and Grounding Terminal: 500VAC 1 minute Power Terminal and Grounding Terminal Ground terminal: When the power specification is 100VAC, 1000VAC for 1 minute. When the power specification is 220VAC, 1500VAC for 1 minute. Common mode noise suppression ratio: 83dB (50Hz). Series mode noise suppression ratio: 46dB (50Hz). Normal working conditions. Environmental temperature: 0-5O ℃ Environment humidity: 5-90% RH (no condensation) Power supply voltage: AC/DC dual-use 100V specification DC drive: 20-130V, non-polar AC drive: 80-138V, 47-63HZ 220V specification DC drive: 120-34OV, non-polar AC drive: 138-264V, 47-63Hz Shape, installation, wiring installation method: Indoor dial installation Dial installation: Use installation accessories (top and bottom) Dial hole size: 137 × 68 (mm) Connection method External signal connection: M4 screw terminal connection Power supply, grounding connection: M4 screw terminal connection External dimensions: 144 × 72 × 320mm (height × width × depth from dial) Weight: 2.6k9

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!