YN194I3-BS three-phase current transmitter
YN194I3-BS three-phase current transmitter
Product details

characteristic:
Measurement: three-phase voltage, three-phase current, voltage current frequency, voltage current power factor, voltage current active power, voltage current reactive power● Display: Single row LED digital display with high visibility.
Communication: RS485 communication, MODBUS-RTU protocol.
Output: Three analog outputs.
summary:
Three phase rail transmitters are suitable for measuring and displaying electrical parameters such as current, voltage, frequency, active power, reactive power, and power factor in power grids and automation systems. By setting the magnification on the panel, the system can intuitively display the electrical parameters during one operation. They have the advantages of high accuracy, good stability, and anti vibration, and can directly replace the original pointer instrumentsTechnical parameters:
| performance | parameter | ||
| transport enter measure measure apparent show |
network | Three phase three wire, three phase four wire | |
| voltage | RATING | AC100~500V | |
| overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
| power consumption | < 1VA (per phase) | ||
| impedance | >500KΩ | ||
| accuracy | RMS measurement, accuracy level 0.5 | ||
| electric current | RATING | AC0~5A | |
| overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
| power consumption | < 0.4VA (per phase) | ||
| impedance | >2MΩ | ||
| accuracy | RMS measurement, accuracy level 0.5 | ||
| frequency | 45~65Hz, Accuracy level 0.1Hz | ||
| power | Visual power, active power accuracy of 1.0 level, reactive power accuracy of 1.5 level | ||
| display | Measurement, active power accuracy level 1.0 | ||
| power supply | scope of work | AC/DC85~270V | |
| power consumption | ≤5VA | ||
| output | Digital Interface | RS-485/MODBUS-RTU protocol | |
| environment | work environment | -10~55℃ | |
| Environment | -20~75℃ | ||
| secure | pressure resistance | Input/power>2kV, input/output>2kV, power/output>1kV | |
| isolation | Input, output, and power supply to the chassis>50M Ω | ||
Wiring method:
Example of ordering:
When signing the contract, please provide detailed information such as product model, input signal, wiring method, etc. This series of products comes with a default appearance setting as standard. If customers have special requirements, please specify them in detail in other projects.Model: YN194I-3BS (three-phase current transmitter)
Online inquiry