Applicable to:Manganese zinc ferrite, nickel zinc ferrite, neodymium iron boron and samarium cobalt, rare earth magnetic materials, water splitting materials, new materials research laboratory According to the criteria; According to ASTM B311, MPIF Standard 42, JIS Z2505, GB/T5163 specifications. Using the Archimedes buoyancy method, the vacuum saturation method, boiling saturation method, and wax sealing method are applied to quickly read measurement values.

Measurement mode:
Mode 1: Silicone oil can be used as a medium to directly read product density and volume
Mode 2: The saturated water method is used to directly read bulk density, wet density, apparent porosity, water absorption, open pore volume, sealed pore volume, and total porosity.
Mode 3: Wax sealing method can directly read bulk density and volume;
Mode 4: The water absorption rate of the absorbent material can be directly read.
Specification: (Both of the following can be measured for product density using silicone oil method. If mercury method is required, please contact the supplier)
Specifications: (The following two types)
Model: | YD-300I | YD-600I |
Weighing accuracy: | 0.005g | 0.005g |
Maximum weight: | 300 | 600 |
Density analysis: | 0.001g/cm3 | |
Measurement type: | Magnetic materials, raw embryos, magnetic materials, mature embryos, shaped parts, and other solid products | |
Measurement time: | About 10 seconds | |
Setting function: | Temperature compensation setting, solution compensation setting, sealing wax density setting, saturated medium density setting | |
Measurement function: | Bulk density, wet density, (apparent porosity, water absorption, total porosity) 0.1% (open volume, closed volume) 0.001cm3 | |
Optional selection; | Printer constant temperature wax furnace vacuum machine | |
Packaging size; (Length, Width, Height) | 45*24*46mm | |
Weight; (Gross weight) | 7.5kg |

Video update in progress



Functional characteristics and devices:
1. No manual calculation required, 2-step operation, 2-5 seconds can quickly read the specific gravity values of various solid particles, and the volume operation is simple;
2. Support one click automatic reset and deduction of auxiliary accessory weight operation;
3. It has temperature and solution compensation setting functions to meet the needs of changing the specific gravity of the measuring medium (water) and changing the measuring medium due to low room temperature;
4. Adopting gold-plated ceramic sensors, it has the characteristics of long corrosion resistance, long service life, and low failure rate
5. Adopting an integrated transparent measuring sink, the size of the integrated sink is: (165*115*856)mm
6. Adopting a lightweight, thin strip, stainless steel suspension rail design can greatly reduce errors caused by the buoyancy of the suspension rail line;
5. Equipment appearance dimensions; (27 * 27 * 27) mm net weight; 4.5kg
7. With an RS-232 standard interface, this densitometer can be easily connected to a computer and printer.
This machine adopts an integrated injection molding measuring frame and an integrated injection molding transparent water tank, which is easy to assemble, wear-resistant, drop resistant, corrosion-resistant, and can clearly observe the condition of the sample in the medium.
Standard attachments:
① Host, ② sink, ③ measuring table, ④ tweezers, ⑤ instruction manual, ⑥ weights, ⑦ windproof and dustproof cover, ⑧ one set of particle measuring accessories, ⑨ one set of float measuring accessories, ⑩ one power transformer

precautions
How to choose a magnetic material density tester
The first step; Can the product be measured with water to confirm whether it absorbs water or not
There are many types of magnetic embryo materials, some have strong water absorption, some have weak water absorption, some will disintegrate when placed in liquids, and some will not disintegrate. Today, we will introduce how to choose
First, confirm the precision we need to purchase
How to choose
If your product weighs less than 10 grams, our company recommends using high-precisionYD-120 weighing accuracy; 0.001-120 can weigh up to 120 grams. If the product weighs more than 10 grams, it can be purchasedYD-300 weighing accuracy 0.005-300YD-The price of 300I is relatively more favorable
Our companyYD-120 YD-300 have the function of measuring with silicone oil method, wax sealing method, and mercury method. If using mercury method, it is necessary to purchase mercury method accessories
Three measurement methods to choose from
Three measurement methods to choose different styles of mercury density meters
Silicone oil method (general magnetic material density tester)
Using solution replenishment method to measure the density of magnetic material embryos using silicone oil. The silicone oil method is not suitable for every magnetic material, as some materials may disintegrate and powder may fall off when placed in solution. This type of magnetic material embryo is not suitable for measurement
Measurement steps of silicone oil method;
First, set the machine solution compensation to the density of silicone oil
The first step; First, place the product on the instrument and measure its weight in the air
Step two; Place the raw product in silicone oil and measure its weight. It takes 4S-5S for the silicone oil to stabilize before pressing the MODE key to directly display the density value
2 Sealing Method (Professional Magnetic Material Density Tester including Method 1)
The wax sealing method is relatively slow and requires patience. It is usually used in schools, research institutes, and other institutions
The first step; Place the sample on the measuring table, measure the weight in the air, and press the M key to memorize.
Step two; After sealing the sample with wax, place it on the measuring table, measure the weight in the air, and press the M key to memorize.
Step three; After sealing the sample with wax, put it into water, measure the weight in the water, press the M key to remember, and directly display the density value.
3 Mercury Method (Mercury Density Tester includes Method 1 and Method 2)
When using mercury method for measurement, it is necessary to take proper ventilation measures
Install the mercury accessories and input the mercury density into the machine
The first step; First, place the product on the instrument and measure its weight in the air
Step two; Measure the weight of the raw product in mercury and display the density value directly
The mercury method is the most effective way to measure embryos, but mercury is harmful to the human body. Please use it with caution
If you purchase a general magnetic material density tester for measuring sintered magnetic material products, it is sufficient

- One year free warranty, lifetime maintenance;
- 7-day no reason return and exchange, 24-hour instant response;
- One on one technical guidance, allowing you to have no worries after purchasing;
- National free consultation hotline: 18659285958.
Data Download | Update Date |
![]() |
2015-08-20 |
Instruction manual download | Update Date |
![]() |
2015-08-20 |
Color page download | Update Date |
![]() |
2015-08-20 |
-
-
Option 1: Customer ------->Business Manager ------->Contract Signing ------->Payment on Delivery ------->Corporate Transfer ------->Warehouse Shipment ------->Confirm Receipt ------->Our Company Invoices
Option 2: Customer ------->Business Manager ------->Contract Signing ------->Cash on Delivery ------->Warehouse Shipment ------->Express Collection ------->Confirm Receipt ------->Our Company Invoices