The XY-885 pipeline density meter adopts an original imported IC multi parameter coplanar flange sensor, which can perform online density measurement on various liquids or liquid mixtures.
The product can be widely used in the petrochemical industry for petroleum, refining, oil blending, and oil-water interface detection; Used in the food industry for production sites such as grape juice, tomato juice, fruit syrup, vegetable oil, and soft drink processing; Dairy industry; Paper industry; Measurement of black slurry, green slurry, white slurry, and alkaline solution; Alcohol content in brewing; Measurement of urea, cleaning agents, ethylene glycol, acidity and alkalinity, and polymer density in the chemical industry. It can also be applied to industries such as mining salt water, potassium alkali, natural gas, lubricants, biopharmaceuticals, etc.
Product features:
1. Two wire transmitter with integrated structure, no moving parts, easy maintenance
2. Five digit LCD display
3. Easy to install and use, simply fill in liquid to display readings
4. Used for fluids or stationary liquids, suitable for pipeline installation
5. Continuous online measurement of liquid density without process interruption, can be directly used for production process control
6. All parts in contact with liquids are made of 316 stainless steel material, which is safe, hygienic, and has good corrosion resistance
7. Intrinsic safety explosion-proof
Technical indicators:
| output signal | Two wire system 4-20mA |
| power supply | 24VDC |
| local display | 4-digit or 5-digit female LCD display |
| Instrument accuracy | 0.1% (at 20 ℃) |
| repeatability | 0.2% |
| Explosion proof performance | Explosion proof water discharge sealed shell, intrinsically safe explosion-proof |
| temperature range | Environment: -40~85 ℃; Process: -20~150 ℃ Storage: -40~100 ℃; Digital display: -10~60 ℃ |
| Start Time | Start 5 seconds after power on |
| Static pressure range | 7Mpa |
| Humidity range | 0~100%RH |
| electrical interface | M20*1.5 |
| Process connection | Flange connection or quick installation chuck (hygienic) |
| Liquid receiving material | 316L stainless steel; HC22; PTFE, etc. (can be customized according to actual working conditions) |
| Installation form | Vertical installation or tank side installation |
| Flow direction of medium | Bottom up or static measurement |
| protection grade | IP65 |
| Shell material | aluminum alloy |
Installation diagram of pipeline density meter: