Cooperate with various analog output sensors and transmitters to measure, transform, display, transmit, record, and control physical quantities such as temperature, pressure, flow rate, liquid level, composition, force, and displacement.
Error less than0.2%F.SIt also has calibration and digital filtering functions, which can help reduce the errors of sensors and transmitters, effectively improving the measurement and control accuracy of the system
Used for voltage, current, thermistor, thermocouplemVSignal types such as potentiometers, remote pressure gauges, etc
Up to8Point alarm output, selectable10Multiple alarm methods, with independent setting of alarm sensitivity. Equipped with delayed alarm function, effectively preventing false alarms caused by interference and other reasons
The transmission output can output the measured and transformed display values in the form of standard current and voltage for use by other devices
A fully transparent, high-speed, and efficient networked communication interface enables complete data transmission and control between computers and instruments. The unique control transfer function allows the computer to directly control the alarm output and transmission output of the instrument. The time to read measurement data once is less than10ms
Provide technical support for testing software, configuration software, and application software
BCDCode interface
Equipped with a printing interface and printing unit with hardware clock, it can achieve manual, timed, and alarm printing functions. If an intelligent printing unit is selected, multiple instruments can share one printer
4 Recording unit can record26Ten thousand measurement data, with adjustable recording intervals. Provide effective means for data analysis and fault diagnosis
4 Multiple external sizes and panel forms, digital tube display, LCD display, and light column display can be flexibly selected
4 For nonlinear signals whose data cannot be determined at the time of ordering and need to be corrected during calibration, instruments can be used8Segment line function
4 1″~ 1
|
content |
Code and Description |
||||||||||
|
XST |
Single display |
||||||||||
|
|
A- |
horizontal format160×80×125Or vertical80×160×125(W×H×L) |
|||||||||
|
B |
96×96×112(W×H×L) |
||||||||||
|
C- |
horizontal format96×48×112Or vertical48×96×112(W×H×L) |
||||||||||
|
D- |
72×72×112(W×H×L) |
||||||||||
|
E- |
48×48×112(W×H×L) |
||||||||||
|
Panel form |
H |
horizontal format |
|||||||||
|
S |
vertical form |
||||||||||
|
F |
square |
||||||||||
|
display mode (LEDThe display color can be customized according to the order requirements) |
1 |
Measurement value (green) |
|||||||||
|
2 |
Measurement value (green)+Set value (red) |
||||||||||
|
3 |
Measurement value (green)+Measurement value light column (green) (limited)AType of Instrument |
||||||||||
|
4 |
Measurement value (green)+Measurement value light column (green)+Set value light column (red) limitA-Stype[U1] |
||||||||||
|
5 |
Measurement value (green)+Measurement value light column (green)+Set value (red) limitA-Stype |
||||||||||
|
input signal (Other input signals, please specify when ordering) |
E |
thermocoupleKTheSTheRTheBTheNTheETheJTheT |
|||||||||
|
R |
thermal resistorPt100TheCu100TheCu50TheBA1TheBA2TheG53 |
||||||||||
|
I |
Direct current(4~20)mA、 (0~10)mAOr(0~20)mA |
||||||||||
|
V |
DC voltage(0~5)V、 (1~5)V |
||||||||||
|
M |
mVSignal (specify range in order) |
||||||||||
|
W |
potentiometer500Ω~5000Ω |
||||||||||
|
L |
Remote Pressure Gauge |
||||||||||
|
Number of alarm points (note)1) |
T□ |
TO: No alarm T1~T4:1~4Point alarm Contact capacity220VAC, |
|||||||||
|
transmitter output (Independent power supply, fully isolated. 10bitD/AThe error is less than ±0.5%) |
A0 |
No output |
|||||||||
|
A1 |
Current output(4~20)mA、 (0~10)mAOr(0~20)mA |
||||||||||
|
A2 |
Voltage output(0~5)V、 (1~5)V |
||||||||||
|
or12bitD./AThe error is less than ±0.2% |
A3 |
Voltage output(0~10)V |
|||||||||
|
A4 |
Other outputs |
||||||||||
|
external power supply |
B0 |
No external power supply |
|||||||||
|
B1 |
external supply24V DC |
||||||||||
|
B2 |
external supply12V DC |
||||||||||
|
B3 |
External precision voltage source |
||||||||||
|
B4 |
External precision constant current source |
||||||||||
|
B5 |
other |
||||||||||
|
Communication interface (note)2) |
S0 |
No communication interface |
|||||||||
|
S1 |
RS-232interface |
||||||||||
|
S2 |
RS-485interface |
||||||||||
|
instrument power supply |
V0 |
85V AC~265V AC |
|||||||||
|
V1 |
10V DC~36V DC |
||||||||||
|
Print function (with hardware clock) |
P |
Indicates with printing function, can be omitted without it |
|||||||||
|
P1 |
Indicating the presence of an integrated printer |
||||||||||
|
Non standard functions (note)3) |
N |
NIndicating non-standard functions |
|||||||||
★ note1:CTheDTheEThe type of instrument is limited to2Point,ATheBThe type restriction is4point
★ note2Independent power supply, fully isolated,2400~19.2KInstrument address99The response delay is less than500uS
★ note3According to usage requirements, including appearance, display mode, reset, alarm lock, maximum value memory, positive and negative polarity input, calculation, etc.
Accurate measurement Fixed classification signal input, maximizing accuracy, resolution, and anti-interference ability based on the characteristics of various signals, using the United StatesCS
EMC III Super strong anti-interference ability, suitable for various complex sites
Wide width power supply Design of switch power supply with high efficiency and wide power supply
Complete isolation Input, output, external supply, and communication are fully isolated
Convenient on-site calibration Equipped with zero point and full degree correction,8End line correction, adjustable digital filtering and other software functions to facilitate problems during coarse particle calibration and improve system accuracy
Multiple types of panels There are dozens of types of panels, and the maximum absorption is sufficient for operation
Reliable communication Communication interface with self diagnosis and self recovery. Transparent and reliable universities
Alarm configuration 10Multiple alarm modes can be set to meet various control requirements
Rich interfaces Capable of printing (manual, timed, alarm)RS232TheRS485Large screen display interface
note1:
IIIGrade: Suitable for typical industrial environments. Places of use for industrial process equipment,Power plants, outdoor high-voltage substations, relay rooms, etc. can serve as representatives of such environments.
IIGrade: Suitable for protected environments. The control rooms or terminal rooms of factories and power plants can serve as representatives of such environments.
IGrade: Suitable for environments with good protection. The computer room can serve as a representative of such environments.
*AC 85V~265V(High efficiency90%),DC 10V~36V
Basic technical specifications
4 electricity Source:85V~265V ACPower consumption is less than7VA;
10V~36V DCPower consumption is less than5VA;
Other power specifications are subject to the accompanying manual
Work environment:
Instruments with a wide temperature range should be specified when ordering
Display range:-1999~9999The decimal point position can be set
Display color: measurement value green, set value red
Display resolution:1/10000
Input signal types: voltage, current, thermistor, thermocouplemVPotentiometer
Remote Pressure Gauge7Seed, among which
electricity Pressure:1V~5V DC,0V~5V DC Can be selected through settings
electricity Flow:4mA~20mA,0mA~10mA,0mA~20mACan be selected through settings
Thermal resistance:Pt100,Cu100,Cu50,BA1,BA2,G53
Can be selected through settings
Thermocouple:K,S,R,B,N,E,J,TCan be selected through settings
Other input signals or division marks need to be specified when ordering
Basic error: less than ±0.2%F.S
Measurement resolution:1/60000,16bitA/Dconverter
Measurement control cycle:0.2second
Technical specifications for selected accessories
alarm output
— 10Various alarm methods can be selected through settings. Delay alarm function
— Relay output: Contact capacity220V AC,
— OCGate output (specified when ordering): voltage less than30VThe current is less than50mA
transmitter output
— opto-isolation
— 4mA~20mA,0mA~10mA,0mA~20mADC current output, selected through setting. Load capacity greater than600Ω
— 1V~5V,0V~5V,0V~10VDC voltage output, please specify when placing an order
— Output resolution:1/3000(Internal resolution)1/4000),
Error less than ±0.2% F.S
communication interface
— opto-isolation
— RS232TheRS485Standard, indicate when ordering
— Instrument address0~99Configurable
— communication rate2400、4800、9600、19200By setting the selection, below2400The speed should be specified when ordering
— The response delay of the instrument from receiving computer commands to sending corresponding data:
To“#”The response delay for the delimiter command is less than500MsThe response delay for other commands is less than100ms
— Supporting testing software, providing technical support for configuration software and application software
Printing interface and printing unit
— Built in hardware clock, power outage does not affect timekeeping, automatically adjusts leap years, major and minor months
— Manual, manual+Scheduled, manual+timing+Alarm three printing methods selected through settings
— Print content: time (year, month, day, hour, minute), alarm status, measured values,
Quantity Unit
— 1The printing unit can only be connected to1Instrument panel, required1When connecting multiple instruments to a printing unit, an intelligent printing unit should be selected
— The printing unit is16Column character micro printer, with the same power supply as the instrument, special printing requirements can be specified when ordering
external power supply
— Ordinary power supply: used to power the transmitter, with a small error between the output value and the nominal value
In ±5%The load capacity is greater than50mA
— Precision power supply: used to supply power to sensors such as pressure and load, with output values and standards
The measurement error is less than0.2%The load capacity is greater than40mA
— 24V DC,12V DC,5V DCOr other specifications, please indicate when ordering
external power supply
— Ordinary power supply: used to power the transmitter, with a small error between the output value and the nominal value
In ±5%The load capacity is greater than50mA
— Precision power supply: used to supply power to sensors such as pressure and load, with output values and standards
The measurement error is less than0.2%The load capacity is greater than40mA
— 24V DC,12V DC,5V DCOr other specifications, please indicate when ordering