XST single input digital intelligent instrument
XST single input digital intelligent instrument, in conjunction with various analog output sensors and transmitters, completes the measurement, transf
Product details
XST single input digital intelligent instrument

Cooperate with various analog output sensors and transmitters to measure, transform, display, transmit, record, and control physical quantities such as temperature, pressure, flow rate, liquid level, composition, force, and displacement.

Error less than0.2%F.SIt also has calibration and digital filtering functions, which can help reduce the errors of sensors and transmitters, effectively improving the measurement and control accuracy of the system

Used for voltage, current, thermistor, thermocouplemVSignal types such as potentiometers, remote pressure gauges, etc

Up to8Point alarm output, selectable10Multiple alarm methods, with independent setting of alarm sensitivity. Equipped with delayed alarm function, effectively preventing false alarms caused by interference and other reasons

The transmission output can output the measured and transformed display values in the form of standard current and voltage for use by other devices

A fully transparent, high-speed, and efficient networked communication interface enables complete data transmission and control between computers and instruments. The unique control transfer function allows the computer to directly control the alarm output and transmission output of the instrument. The time to read measurement data once is less than10ms
Provide technical support for testing software, configuration software, and application software

BCDCode interface

Equipped with a printing interface and printing unit with hardware clock, it can achieve manual, timed, and alarm printing functions. If an intelligent printing unit is selected, multiple instruments can share one printer


4 Recording unit can record26Ten thousand measurement data, with adjustable recording intervals. Provide effective means for data analysis and fault diagnosis

4 Multiple external sizes and panel forms, digital tube display, LCD display, and light column display can be flexibly selected

4 For nonlinear signals whose data cannot be determined at the time of ordering and need to be corrected during calibration, instruments can be used8Segment line function

4 1~ 1

content

Code and Description

XST

Single display

A-

horizontal format160×80×125Or vertical80×160×125W×H×L

B

96×96×112(W×H×L)

C-

horizontal format96×48×112Or vertical48×96×112W×H×L

D-

72×72×112(W×H×L)

E-

48×48×112(W×H×L)

Panel form

H

horizontal format

S

vertical form

F

square

display mode

(LEDThe display color can be customized according to the order requirements)

1

Measurement value (green)

2

Measurement value (green)+Set value (red)

3

Measurement value (green)+Measurement value light column (green) (limited)AType of Instrument

4

Measurement value (green)+Measurement value light column (green)+Set value light column (red) limitA-Stype[U1]

5

Measurement value (green)+Measurement value light column (green)+Set value (red) limitA-Stype

input signal

(Other input signals, please specify when ordering)

E

thermocoupleKTheSTheRTheBTheNTheETheJTheT

R

thermal resistorPt100TheCu100TheCu50TheBA1TheBA2TheG53

I

Direct current(4~20mA、 (0~10mAOr(0~20mA

V

DC voltage(0~5V、 (1~5V

M

mVSignal (specify range in order)

W

potentiometer500Ω~5000Ω

L

Remote Pressure Gauge

Number of alarm points (note)1

T

TO: No alarm T1~T4:1~4Point alarm Contact capacity220VAC,3A

transmitter output

(Independent power supply, fully isolated.

10bitD/AThe error is less than ±0.5%

A0

No output

A1

Current output(4~20mA、 (0~10mAOr(0~20mA

A2

Voltage output(0~5V、 (1~5V

or12bitD./AThe error is less than ±0.2%

A3

Voltage output(0~10V

A4

Other outputs

external power supply

B0

No external power supply

B1

external supply24V DC

B2

external supply12V DC

B3

External precision voltage source

B4

External precision constant current source

B5

other

Communication interface (note)2

S0

No communication interface

S1

RS-232interface

S2

RS-485interface

instrument power supply

V0

85V AC~265V AC

V1

10V DC~36V DC

Print function

(with hardware clock)

P

Indicates with printing function, can be omitted without it

P1

Indicating the presence of an integrated printer

Non standard functions (note)3

N

NIndicating non-standard functions

note1CTheDTheEThe type of instrument is limited to2Point,ATheBThe type restriction is4point

note2Independent power supply, fully isolated,2400~19.2KInstrument address99The response delay is less than500uS

note3According to usage requirements, including appearance, display mode, reset, alarm lock, maximum value memory, positive and negative polarity input, calculation, etc.

Accurate measurement Fixed classification signal input, maximizing accuracy, resolution, and anti-interference ability based on the characteristics of various signals, using the United StatesCS5523A/DConverter ensures measurement accuracy and speed

EMC III Super strong anti-interference ability, suitable for various complex sites

Wide width power supply Design of switch power supply with high efficiency and wide power supply

Complete isolation Input, output, external supply, and communication are fully isolated

Convenient on-site calibration Equipped with zero point and full degree correction,8End line correction, adjustable digital filtering and other software functions to facilitate problems during coarse particle calibration and improve system accuracy

Multiple types of panels There are dozens of types of panels, and the maximum absorption is sufficient for operation

Reliable communication Communication interface with self diagnosis and self recovery. Transparent and reliable universities

Alarm configuration 10Multiple alarm modes can be set to meet various control requirements

Rich interfaces Capable of printing (manual, timed, alarm)RS232TheRS485Large screen display interface

note1

IIIGrade: Suitable for typical industrial environments. Places of use for industrial process equipment,Power plants, outdoor high-voltage substations, relay rooms, etc. can serve as representatives of such environments.

IIGrade: Suitable for protected environments. The control rooms or terminal rooms of factories and power plants can serve as representatives of such environments.

IGrade: Suitable for environments with good protection. The computer room can serve as a representative of such environments.

*AC 85V~265V(High efficiency90%)DC 10V~36V

Basic technical specifications

4 electricity Source:85V~265V ACPower consumption is less than7VA

10V~36V DCPower consumption is less than5VA
Other power specifications are subject to the accompanying manual

Work environment:0~50The humidity is below 90% R.H
Instruments with a wide temperature range should be specified when ordering

Display range:-1999~9999The decimal point position can be set

Display color: measurement value green, set value red

Display resolution:1/10000

Input signal types: voltage, current, thermistor, thermocouplemVPotentiometer
Remote Pressure Gauge7Seed, among which
electricity
Pressure:1V~5V DC0V~5V DC Can be selected through settings
electricity
Flow:4mA~20mA0mA~10mA0mA~20mACan be selected through settings
Thermal resistance:Pt100Cu100Cu50BA1BA2G53
Can be selected through settings
Thermocouple:KSRBNEJTCan be selected through settings
Other input signals or division marks need to be specified when ordering

Basic error: less than ±0.2%F.S

Measurement resolution:1/6000016bitA/Dconverter

Measurement control cycle:0.2second

Technical specifications for selected accessories

alarm output

10Various alarm methods can be selected through settings. Delay alarm function

Relay output: Contact capacity220V AC3A

OCGate output (specified when ordering): voltage less than30VThe current is less than50mA

transmitter output

opto-isolation

4mA~20mA0mA~10mA0mA~20mADC current output, selected through setting. Load capacity greater than600Ω

1V~5V0V~5V0V~10VDC voltage output, please specify when placing an order

Output resolution:1/3000(Internal resolution)1/4000),

Error less than ±0.2% F.S

communication interface

opto-isolation

RS232TheRS485Standard, indicate when ordering

Instrument address0~99Configurable

communication rate24004800960019200By setting the selection, below2400The speed should be specified when ordering

The response delay of the instrument from receiving computer commands to sending corresponding data:
To“#”The response delay for the delimiter command is less than500MsThe response delay for other commands is less than100ms

Supporting testing software, providing technical support for configuration software and application software

Printing interface and printing unit

Built in hardware clock, power outage does not affect timekeeping, automatically adjusts leap years, major and minor months

Manual, manual+Scheduled, manual+timing+Alarm three printing methods selected through settings

Print content: time (year, month, day, hour, minute), alarm status, measured values,
Quantity Unit

1The printing unit can only be connected to1Instrument panel, required1When connecting multiple instruments to a printing unit, an intelligent printing unit should be selected

The printing unit is16Column character micro printer, with the same power supply as the instrument, special printing requirements can be specified when ordering

external power supply

Ordinary power supply: used to power the transmitter, with a small error between the output value and the nominal value
In ±5%The load capacity is greater than50mA

Precision power supply: used to supply power to sensors such as pressure and load, with output values and standards
The measurement error is less than0.2%The load capacity is greater than40mA

24V DC12V DC5V DCOr other specifications, please indicate when ordering

external power supply

Ordinary power supply: used to power the transmitter, with a small error between the output value and the nominal value
In ±5%The load capacity is greater than50mA

Precision power supply: used to supply power to sensors such as pressure and load, with output values and standards
The measurement error is less than0.2%The load capacity is greater than40mA