XSJDL series quantitative controller
XSJDL series quantitative controller RSJDL series quantitative controller works in conjunction with various flow sensors and transmitters to achieve q
Product details
RSJDLSeries quantitative controllerCooperate with various flow sensors and transmitters to achieve quantitative canning and ingredient control.
- The error is less than 0.2% F.S, and it has calibration and digital filtering functions, which can help reduce the errors of sensors and transmitters and effectively improve the measurement and control accuracy of the system
- Flow sensors suitable for current, voltage, and pulse output
- 3-point switch input, used for starting, restoring, and resetting accumulated values each time
- 3-point control output, used for graded control of large and small valves and instantaneous flow lower limit alarm
- The transmission output can output the instantaneous flow value in the form of standard current and voltage for use by other devices
- The 8-segment line calculation function can reduce the nonlinear error of flow sensors
- Instantaneous flow can be measured in hours or minutes
-
A fully transparent, high-speed, and efficient networked communication interface enables complete data transmission and control between computers and instruments. The unique control transfer function allows the computer to directly control the working status and transmission output of the instrument. The time to read measurement data once is less than 10ms
Provide technical support for testing software, configuration software, and application software -
Equipped with a printing interface and printing unit with hardware clock, realizing manual, timed, and alarm printing functions. If an intelligent printing unit is selected, multiple instruments can share one printing unit
Basic configuration:
Dual display, 2-point input and 3-point output, external transmitter power supplySelection TablecontentCode and DescriptionXSJDL/Dual display, 3-point input and output, external transmitter power supplyinput signalIdirect currentVDC voltageKpulseexternal power supplyB0No external power supplyB1External supply 24V DC, error less than ± 5%, 50mAB2External supply 12V DC, error less than ± 5%, 50mAB3othertransmitter outputA0No outputA1Current output (4~20) mA, (0~10) mA, or (0~20) mAA2Voltage output (0~5) V, (1~5) VA3Voltage output (0~10) VA4Other outputsCommunication interface (independent power supply, fully isolated, 2400~19.2K instrument address 0~99, response delay less than 500 μ s)S0No communication interfaceS1RS-232 interfaceS2RS-485 interfaceS3RS 422 interfaceinstrument power supplyV0220V ACV124V DCV212V DCPrint functionPP represents the printing interface, which can be omitted if not includedNon standard functionsNN represents non-standard function