The XMPA-3000 intelligent PID controller does not have adjustable components and does not require any auxiliary functional modules. All parameter sett
Product details
智能PID调节器智能PID调节器智能PID调节器

Product Overview/Product overview----------------------------------------------------------◆◆

Welcome to use our company's intelligent PID regulator. There are no adjustable components inside this instrument, and no auxiliary function modules are required. All parameter settings, function mode selection, and accuracy calibration of analog input and output are achieved through the buttons on the instrument panel. In order to use the instrument correctly and reasonably, and fully utilize its various functions, please read the subsequent sections of this manual carefully before use. The instrument has been correctly set according to your ordering requirements before leaving the factory. If you want to change the corresponding setting parameters, it must be operated by personnel familiar with the industrial control site who fully understand the performance of this instrument. If you have any new suggestions or ideas during use, please inform our company in a timely manner so that we can provide you with better products.

Main performance/main performance---------------------------------------------------------◆◆

1. More than 20 input signals can be selected (measurement input signals can be square root and small signal cut)
2. Multiple displays including process quantity, given value, control quantity, valve position feedback quantity, etc. The display of measured values and given values can be added or subtracted.
3. Selection of positive and negative effects for PID regulation of control variables.
4. The upper and lower limit amplitudes of the PID regulator can be independently set.
5. PID parameter self-tuning or independent self-tuning of P parameter.
6. Power on automatically or manually, and the manual output value can be pre-set.
7. Manual automatic bidirectional disturbance free switching and manual status indication and output.
8. Input the switch quantity SB function to control the displacement of the given value.
9. Two or three analog outputs.
10. The instrument can have up to six switch outputs, and one switch can be set to selectively monitor the other two switches, achieving intelligent sound and light alarm function with silencing time.
11. Remote control of EM1 and EM2.
12. The 50Hz synchronous bidirectional thyristor zero crossing compensation control algorithm is used to achieve optimized control of each main wave, avoiding high-order harmonic pollution of the power grid caused by high-power loads.
13. The intermittent PID regulator instrument can directly control single resistive loads with AC below 2KM or output 3 sets of synchronous signals triggering bidirectional thyristors below 500A for users with built-in 40A bidirectional thyristors.
14. 8 sets of given values SP1 and P, I, D parameter storage and calling.
15. The control output of the remote switch quantity control regulator is PID regulation mode or hold state, with bidirectional disturbance free switching.
16. Set the given values and PID parameters online without disturbance.
17. The control input of the remote switch quantity control regulator is PID regulation mode or tracking state, with bidirectional disturbance free switching.
18. At the same time as PID regulation or positional control, the instrument can define one or two relays to achieve a dual channel timing function with a timing accuracy of 10-5 for each channel up to 100 hours.
19. Fault control output can be achieved after resistance, disconnection, and disconnection, as well as fault control output for valve position feedback blockage or disconnection (1-5, 4-20mA).

Product selection/product selection-----------------------------------------------------------◆◆

XMPA —— Remarks
Design sequence 3 3000 series instrument
Display mode 1 Dual screen display
2 Three screen display
3 Dual screen+single light column
4 Dual screen+dual light pillar
5 Single screen+dual light pillar
6 Single screen+three light pillars
Input method 1 Equipped with thermocouples (E, K, S, B, J, T, R, N)
2 Heating resistors (Pt100, Cu50, Cu100, BA1, BA2, G)
3 Equipped with DC current (0~10mA, 4~20mA)
4 Equipped with DC voltage (0~5V, 1~5V, 0~20mA, 0~75mA, 0~200mA)
5 Equipped with remote transmission pressure resistance value and linear resistance value (0~400 Ω)
6 Equipped with all types 1 to 5, users can change any input type at any time
7 Frequency input (0~10KHz)
8 Special inputs (such as square root, small signal cutoff, please specify when ordering)
Control output and adjustment mode Continuous PID method 1 PID4~20mA output (reactive)
2 PID0~10mA output (reactive)
3 PID0-5V output (reverse effect)
4 PID1-5V output (reverse effect)
5 PID0~10V output (reactive)
6 Positive effect (one of 1-5, indicate when ordering)
7 One of 1-6+relay (indicate the type and quantity of relay when ordering)
Intermittent PID method 1 Built in thyristor (bidirectional 41A, within 2KW) output
2 Built in thyristor (bidirectional 41A, within 2KW) output (2 or 3 relays can be added, please specify when ordering)
3 External thyristor (single or double silicon)
4 External thyristor (single or double silicon) (2 or 3 relays can be added, please specify when ordering)
5 Using three-phase zero crossing interpolation method for thyristor triggering (with a triggering current of over 500mA)
6 Three phase zero crossing thyristor trigger with 1 or 2 relays (specified in order)
7 SSR solid-state relay output (12V) with 2 relay alarms (user provided SSR technical parameters)
Additional functions (note) 0 No additional features
1 There are output upper and lower limit control ranges
2 Has manual startup function
3 EM1 function
4 EM2 function
5 SB function
6 Self tuning function
7 8 sets of PID parameter selection
8 Ratio control: SP=A × external given+B
9 Valve position feedback display and tracking control (default input 4-20mA or order instructions)
External dimensions H Horizontal 160 × 80 Opening 152 × 76
V Vertical 80 × 160 Opening 76 × 152
F Method 96 × 96 Opening 92 × 92
Q Method 72 × 72 Hole 68 × 68
Transmission output A No transmission output
B Transmission output 0~10mA
C Transmission output 4~20mA
D Transmission output 0~5V
E Transmission output 1~5V
F Special signal transmission output
G Feedback output (default input)
Timing S Default is no timed function
Equipped with timing function
External 24V DC power supply P Default is no 24V DC power output
With 24V DC power output (can be used as a two-wire transmitter power supply)
communication interface T Default is without communication interface
Equipped with RS485 or RS232 communication interface
power supply

K

W

The default is 220V AC
Switching power supply 85~260VAC
Switching power supply 18~36VDC or 18~36VAC
Note: There are multiple optional additional functions. When placing an order, add their serial numbers together and mark them all. Only one of 4, 5, and 6 can be selected and added to other functions.

Technical indicators/Technical indicators---------------------------------------------------------◆◆

1. Measurement accuracy: ± 0.5% FS+1d ± 0.2% FS+1d
2. Analog input impedance: current signal: ≤ 50 Ω; Voltage signal: ≥ 500kΩ
3. Analog output impedance: Current signal: 0~10mA ≥ 1.5k Ω; 4~20mA≥750Ω
Voltage signal: 0~5V, 1~5V output impedance ≤ 1 Ω
4. Switching output, AC 220V, 3A (resistive load)
5. Manual/automatic status output: Automatic status is off; Manual status is on
6. Parameter retention time set after power outage: ≥ 20 years
7. Insulation impedance: AC voltage 1500V, 1 minute
8. Insulation impedance: above 50M Ω
9. Work environment requirements: Temperature: 0~50 ℃, relative humidity ≤ 85%, no corrosive gases, no vibration in the environment.

Display explanation--------------------------------------------------------------◆◆

1. Dual screen display
When measuring with the upper digital tube, the input measurement signal is displayed, and the prompt for setting parameters is displayed when entering the parameter setting mode.
★ The lower digital display shows the percentage of the regulator's given value or control quantity, or the percentage of valve position feedback quantity (please specify when ordering). When in manual mode, display the manual output control quantity in percentage form. When entering the parameter setting mode, display the set parameters.
2. Dual screen+single analog strip
When measuring with the upper digital tube, the input measurement signal is displayed, and when entering the parameter setting mode, a prompt for setting parameters is displayed.
★ The lower digital display shows the percentage of the regulator's given value or control quantity, or the percentage of valve position feedback quantity (please specify when ordering). When in manual mode, display the manual output control quantity in percentage form. When entering the parameter setting mode, display the set parameters.
★ Simulation bar displays the percentage of valve position feedback or PID control quantity (please specify when ordering)
3. Single screen+dual-mode strip simulation
When measuring with a digital tube, display the input measurement signal or the given value of the regulator, or display the valve position feedback signal in percentage form, or display the control quantity in percentage form. Use the plus key to switch the display mode. When in manual mode, display the manual output control quantity in percentage form. When entering the parameter setting mode, alternately display the prompt for setting parameters and the setting parameters.
The left analog bar displays the measurement signal of the main input in percentage form.
The right analog bar displays the given value of the regulator, valve position feedback, or PID control in percentage form.
4. Dual screen+dual-mode strip simulation
When measuring with the upper digital tube, the input measurement signal is displayed, and when entering the parameter setting mode, a prompt for setting parameters is displayed.
★ The lower digital display shows the percentage of the regulator's given value or control quantity, or the percentage of valve position feedback quantity (please specify when ordering). When in manual mode, display the manual output control quantity in percentage form. When entering the parameter setting mode, display the set parameters.
The left analog bar displays the measurement signal of the main input in percentage form.
The right analog bar displays valve position feedback or PID control in percentage form.
5. Three screen display
When measuring with the upper digital tube, the input measurement signal is displayed, and when entering the parameter setting mode, a prompt for setting parameters is displayed.
★ The middle row digital display shows the percentage of valve position feedback. When in manual mode, display the manual output control quantity in percentage form. When entering the parameter setting mode, display the set parameters.
★ The lower digital display shows the percentage of control quantity.
6. Single digit display+three analog bars
When measuring with the upper digital tube, the input measurement signal, control quantity, tracking quantity, or given value is displayed, and the display mode can be selected with the key. Set the prompt to alternately display the set parameters and the set parameters.
The first 24 line analog strip displays the measurement signal of the main input in percentage form.
The second 24 analog bars display the given value in percentage form.
The third 24 line analog bar displays the control quantity in percentage form.
7. Indicator light
★ LED-A is an intermittent PID control or SP1 alarm status indicator light
★ LED-E is the SP2 alarm status indicator light
★ LED-B is the SP3 alarm status indicator light
★ LED-C is an automatic indicator light or SP4 alarm status indicator light
★ LED-G is a manual indicator light
★ LED-D is the control quantity status indicator light displayed on the lower row digital tube
★ LED-F is the process status indicator light displayed on the lower row digital tube
★ LED-H is an external given status indicator light

Instrument wiring/Instrument wiring-----------------------------------------------------------◆◆

Wiring Diagram 1
智能PID调节器接线指南
Wiring diagram 2
智能PID调节器接线指南
Wiring diagram three
智能PID调节器接线指南
Wiring diagram four
智能PID调节器接线指南
Note: If there are differences, the wiring diagram with the instrument shall prevail.

Instrument usage and maintenance/Instrument use and maintenance------------------------------------◆◆

1. The instrument should be placed in a dry, ventilated and non corrosive gas environment, and the ambient temperature and relative humidity should meet the technical conditions.
2. According to your needs, please select the instrument model and relevant program correctly so that users can use it without debugging or directly.
3. Due to the multiple functions of the instrument, it is necessary to correctly set the menu operation program and wiring according to the working conditions. If necessary, it is recommended that the user send personnel to the manufacturer for learning.
4. If the instrument is damaged due to quality issues with the manufacturer, it will be repaired free of charge by the manufacturer within one year.

Product packaging/Product packaging----------------------------------------------------------◆◆

智能PID调节器产品包装

Logistics Description/Logistics instructionss-------------------------------------------------------◆◆

智能PID调节器物流说明
智能PID调节器企业资质智能PID调节器营业执照
智能PID调节器客户现场图
智能PID调节器公司车间
智能PID调节器买家必读

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!