◆ Overview
OW-XMDA-9000The series of intelligent multi-point touring display adjustment instruments is no longer simply display instruments in the past. Most products in this series of instruments have strong processing capabilities such as calculation, comparison, execution, and alarm.
This instrument adopts a dedicated integrated circuit developed independently and customized by a Japanese integrated circuit manufacturer. It gathers most of the functions of various regulating instruments in current automatic control systems, and also integrates circuits such as CPU, I/O interface, EPROM, and D/A conversion, as well as a software system that draws on various strengths, carefully compiles, and repeatedly debugs.
◆ Characteristics
The hardware of the instrument has been significantly reduced, and the composition structure of the system is relatively simple. Within the scope of user application, multiple input signals are compatible.
Adopting optimized design, the process has been significantly improved, without flying wires or adjusting potentiometers. All calibration and function settings can be completed by software through the keyboard.
It can be set as a four point control with twelve point inspection function. It can be set as a unified point alarm or an independent separate alarm function.
Up to four alarm outputs can be set, with more than ten alarm methods and the ability to monitor each alarm point with sound and light. The alarm sound can also be silenced with a delay time.
● Four categories with nearly a hundred levels of anti-interference modes set by users themselves, which can adapt to interference sources in various environments.
◆ Function
Input signal types: thermocouple, thermistor, linear current, linear voltage.
Number of inspection channels: 1-16. The instrument can display four measurement values simultaneously.
● Can switch between inspection and scheduled inspection, with channel display time setting, selectable from 0.1 to 25 seconds.
Each channel can be individually set to be effective.
Linear input can define the zero point, full-scale value, and decimal place of each channel.
● Support independent setting of upper and lower limit alarm values and alarm light indication for each channel; Unified relay output for upper and lower limits or shared relay output for every 4 channels.
● Four relay combinations can be selected for allocation.
You can see the average value, which can be controlled in a positional manner.
● Adjustable alarm output (including sound and light alarm output).
● It can realize the transmission of the most current value, minimum value, average value, and instantaneous value to the output simultaneously or separately.
According to the operation function, it has three sets of menus: B, C, and E, among which the C menu is convenient and quick.
Can provide RS485 asynchronous serial communication with multiple hosts, single host, and no host modes. Communication data verification follows the CRC-16 American data communication standard, with high reliability cycling and barcode verification.
Main technical indicators
Measurement accuracy: ± 0.5% FS+1 word
● Adjustment control accuracy: Position: ± 0.5% FS
● Alarm function: upper limit, lower limit, upper and lower limits, lower return difference, double return difference, etc
Input impedance: 0-10mA: 50 Ω, 4-20mA: 250 Ω, thermocouple and DCmV: ≥ 10KΩ
Cold end automatic compensation accuracy: ± 0.3 ℃ within the range of 0-40 ℃
Thermal resistance: fully compensated within 3 × 10 Ω for three wire input
● Relay contact capacity: AC220V 2A
● Power supply: AC220V ≤6W AC110V DC24V
Work environment requirements: temperature: 0-50 ℃, relative humidity:<85%, no corrosive gases, no vibration in the environment.
◆ Selection method
OW
enterprise standard
Model
XMDA
Digital display multi-point monitoring instrument (analog input) (artificial intelligence, enhanced)
DesIgn Serial Number
9
Input function
0
Linear resistance: 0-400 Ω
1
Thermocouple division number: K、E、S、B、J、T、N、EA
2
Thermal resistance index number: Pt100、BA1、BA2、Cu100、Cu50
3
Linear current: 0-10 mA, 4-20 mA
9
Full signal input (including all 1-5)
output function
0
no-output
1
4~20mA or 1-5V
2
0~10mA or 1-5V
Transmission output value selection
1
Instant value
2
Maximum value
3
minimum value
4
average value
Alarm
0
No alarm
1
Alarm all the way
2
Two way alarm
3
Three way alarm
9
Four way alarm
On-Site Inspectionpassage
1
4Road inspection
2
8Road inspection
3
12Road inspection
4
16Road inspection
External dimensions
B
Panel size 160 × 80 with openings 152 × 76
F
Panel size 96 × 96 with openings 92 × 92
H
Panel size 80 × 160 with openings 76 × 152
Power supply mode
W
DC 24Vpower supply
T
Switching power supply 85-265V AC
M
220V. AC(Can be omitted)