Water saving low film-forming temperature measuring instrument
The water-saving low film-forming temperature measuring instrument adopts the principle of compressor cooling, no longer using circulating water cooli
Product details

1Water saving low film-forming temperature measuring instrument[Product Introduction]

When polymer lotion is used as a surface treatment agent for coatings, adhesives, chemical fiber fabrics, leather, paper and other surfaces, its film-forming property is one of the important technical indicators. In order to produce new products with lower film-forming temperature, researchers constantly improve its technical specifications and formula, which can easily measure its MFT.

Water saving low film-forming temperature measuring instrumentJingqiang (Tianjin)Test Instrument Technology Co., Ltd. is based on the national standard lotion for Paint and Polymer Dispersion for Paint and Plastic (GB/T9267-2008)ZDesigned and manufactured for the determination of low film-forming temperature,This machine adopts the principle of compressor cooling and no longer uses circulating water for cooling, solving the problem of water waste during the testing process. At the same time, the machine adopts a cabinet design, which saves more space.

IIWater saving low film-forming temperature measuring instrument[Technical Parameters]

1Gradient plate working temperature range: Cold end:- two0,Hot end: 70 ℃

2. Gradient board detection points: 13

3. Gradient interval: 20mm

4. Test paint tank: 6 strips, length 240mm, width 22mm, depth 0.25mm

5. The inspection table shows that at 16:00, points 1-13 are the working gradient temperature, point 14 is the instrument environment temperature, and points 15 and 16 are the inlet and outlet temperatures of the cooling water

6. Power supply: 220V 50Hz

7Cooling water source:Compressor refrigeration

8Instrument dimensions: Length 550mm x Width 520mm x Height950mm

9. Instrument weight: 120Kg

IIIWater saving low film-forming temperature measuring instrument[Product Features]

1. Compressor cooling, fast cooling speed, gradient plate low temperature can reach -20 ℃;

2. No need to use circulating water during the experiment, in response to energy-saving and environmental protection requirements;

3, cabinet styleDesign, more space saving

4. More advanced gradient plate design for greater volume reduction;

5. Accurate calibration of surface temperature, combined with a temperature scale, ensures accurate and reliable measurement data;

6. A wider workbench can measure 6 sets of samples simultaneously.