Walk in temperature and humidity laboratory
Product Usage: The walk-in temperature and humidity laboratory is an essential testing equipment in the fields of aviation, automotive, home appliance
Product details
| Device Model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
| LRHS-8MB-LJS | 2000×2000×2000 | According to the three views of the contract | |
| LRHS-15MB-LJS | 2500×3000×2000 | ||
| LRHS-30MB-LJS | 3000×5000×2000 | ||
| LRHS-60MB-LJS | 5000×6000×2000 | ||
|---|---|---|---|
Technical Specifications
Sales Hotline: 021-608 99999
| sex can point mark |
temperature range | A:-20℃~100℃ B:-40℃~100℃ C:-60℃~100℃ D:-70℃~100℃ |
|||
| Temperature Uniformity | ≤ 2 ℃ (when unloaded) | ||||
| temperature fluctuation | ± 0.5 ℃ (when unloaded) | ||||
| Time setting range | 1~60000M | ||||
|---|---|---|---|---|---|
| humidity range | 30%~98% RH | ||||
| humidity uniformity | +2% -3% RH | ||||
| Humidity fluctuations | ±2% | ||||
| heating rate | -40℃~100℃≤90min | ||||
| 降温速率 | 100℃~-40℃≤90min | ||||
| make use material material |
outer box material | High quality storage board, CNC precision machining | |||
| Inner box material | Imported high-grade stainless steel SUS304 | ||||
| Insulation material | Rigid polyurethane foam+glass fiber | ||||
| nucleus heart match place |
Temperature and humidity controller | Imported "Youyi Control" brand temperature and humidity instruments | |||
| temperature and humidity sensor | PT100 platinum resistance thermometer | ||||
| Cooling method | Single machine or double machine cascade refrigeration | ||||
| compressor | France Taikang/Germany Bizelle/Germany Ancient Wheel | ||||
| Standard Configuration | Wet ball gauze, emergency stop switch, three color indicator light | ||||
| safety protection | Compressor overpressure overload, overheating, fan motor overheating, leakage protection Overall equipment under phase/reverse phase, overall equipment timing, overload and short circuit protection |
||||
| power supply voltage | AC380V±10% 50Hz | ||||
| Power | (A) 20.0kW/31.0kW 48.0kW/60.0kW (B) 25.0kW/38.5kW 55.0kW/72.0kW (C) 34.5kW/48.5kW 62.5kW/80.0kW |
||||
| Usage environment | 5℃~+28℃ ≤85% RH | ||||
| Note: 1. The data was measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. The above parameters are for reference only and can be customized according to the specific testing parameters of the user 3. This technical information is subject to change without prior notice |
|||||