Zibo Jieyou Pump Industry Co., Ltd
Home>Products>WQK and QG type cutting submersible sewage pumps
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15589352061
  • Address
    No. 19-1, Dahaiyan Section, Zhangbo Road, Boshan District, Zibo City, Shandong Province
Contact Now
WQK and QG type cutting submersible sewage pumps
WQK and QG type cutting submersible sewage pumps
Product details
brand Jieyou model WQK and QG type cutting submersible sewage pumps material stainless steel
performance corrosion-resistant purpose submersible pump Drive Type hydraulic
conveyed medium Sewage pump, impurity pump Pump shaft position Edge standing impeller structure Semi open impeller
Impeller suction method Single suction type traffic 69(m3/h) Number of impellers 1-30
head 60(m) Inhalation caliber 60(mm) Discharge diameter 50(mm)
structural principle Mid open pump series single-stage voltage 380(V)
power 5.5(kw)
detailed explanation
、 Product features of WQK and QG cutting submersible sewage pumps:
The WQK/QGWQK and QG type cutting submersible sewage pumps have particularly strong sewage passing capacity and good cutting performance. They can chop up impurities such as long fibers, plastics, paper, belts, cloth strips, straw, ropes, etc. in the sewage and discharge them. Using the most advanced methods and designed with the most reasonable hydraulic characteristics, the electric pump can operate at full head. The best combination of excellent dry motor and water pump, the electric pump uses high-quality hard alloy, double end mechanical seal and skeleton oil seal assembly parts, which should not exceed 1/2 of the height of the motor, and the temperature of the pumped waste should not exceed 40 ℃.
2、 The product uses of WQK and QG cutting submersible sewage pumps are:
The WQK/QGWQK and QG cutting submersible sewage pumps are mainly used for engineering sewage and domestic sewage.
For example, (1) WQK and QG type cutting submersible sewage pumps are used in construction sites, engineering foundation construction, municipal facilities, and water treatment plants.
(2) Sewage discharge from the basement of various high-rise buildings, civil air defense pits, subways, and other underground structures.
(3) Sewage treatment and circulating water transportation for small and medium-sized enterprises.
(4) The pumping of slag and slurry from factories and mining enterprises such as food, paper, brewing, steel and non-ferrous metals, leather, textile, pharmaceutical, cement plants, etc.
(5) Chicken farms, pig farms, various animal husbandry industries, fish ponds are used for pumping and cleaning ponds, oxygenation, septic tanks, and other occasions for the transportation of human and animal manure and urine.
Note: The main performance and data of wqk are the same as those of wqk/qg type, except for the absence of cutting device.
3、 Performance parameters of WQK and QG cutting submersible sewage pumps:
model
caliber
(mm)
traffic
(m3/h)
head
(m)
Motor power
(kw)
speed
(r/min)
voltage
(v)
WQK7-10QG
25
7
10
0.75
2900
380
WQK8-22QG
25
8
22
1.1
2900
380
WQK7-20
25
7
20
1.5
2900
380
WQK7-10QG
32
7
10
0.75
2900
380
WQK8-12QG
32
8
12
0.75
2900
380
WQK12-15QG
32
12
15
1.1
2900
380
WQK7-20QG
32
7
20
1.5
2900
380
WQK10-12QG
40
10
12
1.1
2900
380
WQK10-15QG
40
10
15
1.5
2900
380
WQK15-15QG
40
15
15
2.2
2900
380
WQK15-30QG
40
15
30
2.2
2900
380
WQK10-7QG
50
10
7
0.75
2900
380
WQK20-7QG
50
20
7
0.75
2900
380
WQK10-15QG
50
10
15
1.5
2900
380
WQK20-10QG
50
20
10
1.5
2900
380
WQK20-15QG
50
20
15
1.5
2900
380
WQK15-18QG
50
15
18
2.2
2900
380
WQK20-20QG
50
20
20
2.2
2900
380
WQK40-7QG
50
40
7
2.2
2900
380
WQK15-25QG
50
15
25
2.2
2900
380
WQK25-15QG
50
25
15
3
2900
380
WQK42-9QG
50
42
9
3
2900
380
WQK18-30QG
50
18
30
3
2900
380
WQK15-32QG
50
15
32
4
2900
380
WQK25-22QG
50
25
22
4
2900
380
WQK30-20QG
50
30
20
4
2900
380
WQK40-15QG
50
40
15
4
2900
380
WQK20-32QG
50
20
32
5.5
2900
380
WQK25-40QG
50
25
40
7.5
2900
380
WQK25-10QG
65
25
10
1.5
2900
380
WQK20-15QG
65
20
15
2.2
2900
380
WQK30-10QG
65
30
10
2.2
2900
380
WQK25-15QG
65
25
15
2.2
2900
380
WQK37-13QG
65
37
13
3
2900
380
WQK25-15QG
65
25
15
3
2900
380
WQK25-30QG
65
25
30
4
2900
380
WQK40-15QG
65
40
15
4
2900
380
WQK25-25QG
65
25
25
4
2900
380
WQK25-32QG
65
25
32
5.5
2900
380
WQK40-20QG
65
40
20
5.5
2900
380
WQK25-40QG
65
25
40
7.5
2900
380
WQK25-6QG
80
25
6
1.1
2900
380
WQK30-7QG
80
30
7
1.5
2900
380
WQK40-7QG
80
40
7
2.2
2900
380
WQK30-30QG
80
30
30
3
2900
380
WQK30-15QG
80
30
15
3
2900
380
WQK40-10QG
80
40
10
3
2900
380
WQK50-8QG
80
50
8
3
2900
380
WQK40-15QG
80
40
15
4
2900
380
WQK60-10QG
80
60
10
4
2900
380
WQK60-20QG
80
60
20
5.5
1450
380
WQK50-15QG
80
50
15
5.5
1450
380
WQK80-10QG
80
80
10
5.5
1450
380
WQK45-20QG
80
45
20
5.5
1450
380
WQK65-25QG
80
65
25
7.5
1450
380
WQK50-25QG
80
50
25
7.5
1450
380
WQK80-20QG
80
80
20
7.5
1450
380
WQK20-50QG
80
20
50
5.5
2900
380
WQK20-60QG
80
20
60
7.5
2900
380
WQK85-10QG
100
85
10
4
1450
380
WQK65-15QG
100
65
15
5.5
1450
380
WQK100-8QG
100
100
8
5.5
1450
380
WQK100-15QG
100
100
15
7.5
1450
380
WQK85-20QG
100
85
20
7.5
1450
380
WQK100-25QG
100
100
25
11
1450
380
WQK80-32QG
100
80
32
15
1450
380
WQK100-30QG
100
100
30
15
1450
380
WQK100-40QG
100
100
40
15
1450
380
WQK115-15QG
125
115
15
11
1450
380
WQK130-20QG
125
130
20
15
1450
380
WQK130-10QG
150
130
10
7.5
1450
380
WQK140-7QG
150
140
7
7.5
1450
380
WQK130-15QG
150
130
15
11
1450
380
WQK150-10QG
150
150
10
11
1450
380
WQK180-15QG
150
180
15
15
1450
380
WQK200-10QG
150
200
10
15
1450
380

4、 Precautions for using WQK and QG type cutting submersible sewage pumps
(1) Before using the WQK and QG type cutting submersible sewage pumps, it is necessary to first check whether the cables are damaged. When handling and installing the water pump, cut iron to pull or damage the cables to avoid accidents caused by cable rupture and water leakage. If the cable cracks hard, it should be replaced immediately. And use a megohmmeter to check if the insulation resistance of the electric pump is normal (the insulation resistance should not be less than 1 megohm)
(2) Identify the grounding wire (usually yellow or green or marked with a grounding symbol), and follow the prescribed procedures to properly connect the grounding wire. Our factory's grounding wire is equipped with a grounding sign.
(3) Choose appropriate protectors (such as leakage protectors, air switches, phase failure overcurrent protectors, etc.) and do not directly connect them with knife switches.
(4) Connect the power cord of the WQK and QG cutting submersible sewage pumps according to the standard, test the power supply, check if the electric pump is running normally, and determine if the direction of rotation is correct. If the direction of rotation is incorrect, swap any two of the three power cords (note that the operating time should not exceed half a minute).
(5) Install the water outlet connector and water outlet hose (or iron pipe), tie a rope on the electric pump handle (never use a cable to replace the hanging rope), place the electric pump into the pump to be pumped, turn on the power, and it can be used.
(6) In order to ensure personal safety, it is strictly prohibited to install water operations (such as moving, inspecting, troubleshooting, etc.) near the electric pump during the operation of the electric pump. Contact with the electric pump is necessary to prevent accidents caused by electric pump leakage!
(7) It is strictly prohibited to expose the entire electric pump to the water surface for long-term operation (or short-term operation). The "on" and "off" of WQK and QG type cutting submersible sewage pumps should not be overly frequent to prevent motor overheating and damage
(8) Long term pumping of liquids with high sand content causes significant wear on the flow components. We recommend using our factory's cyclone type submersible sewage pump products.
(9) If abnormal phenomena such as non rotation, tripping of protective devices, and blown fuses are found during the operation of WQK and QG type cutting submersible sewage pumps, the power supply should be immediately cut off and the wiring of the power protection device should be checked for any problems. If these external devices are all normal, it may be a fault with the electric pump, and it should not be continued to be used to avoid accidents!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!