productpurpose
Used for unorganized emission testing; Unorganized emissions refer to the irregular discharge of waste gas pollutants generated during the production process and not through exhaust pipes. The sampling location is the main production workshop and factory boundary.
System Characteristics
1Fully functional and can be monitoredVOCsIt has five meteorological parameters and can be extended to other gases;
2Built in usability10000An hour's worth of imported air pump and automatic control of its flow rate1.0L/Min;
3Adopting imported technologyPIDDetector, with monitoring accuracy up toppbGrade;
4External air pre-treatment device can effectively filter dust and water vapor;
5Modular design reduces operation and maintenance costs;
6Equipped with a large capacity high-performance battery, it can ensure operation after power failure48More than hours;
7Optional online factory interfaceVOCsDetection system;
8The shell has a temperature self regulating function, equipped with a heat shield, and effectively controls the temperature of the box through nano thermal insulation spraying materials and internal circulation system.
Serial Number |
Gas name |
detection range |
check the accuracy |
resolution |
1 |
Cl2 |
0–5 ppm |
< 5% |
50ppb |
2 |
HCl |
0–30 ppm |
< 5% |
< 0.1 ppm |
3 |
H2S |
0–30 ppm |
< 5% |
< 0.05 ppm |
4 |
NH3 |
0–100 ppm |
< 10% |
< 1 ppm |
5 |
VOC |
0–10 ppm |
< 5% |
10ppb |
6 |
SO2 |
0–10 ppm |
< 5% |
10ppb |
Main technical parameters
※ Detection principle: photoionization detector(PID)
※ Sampling method: pump suction
※ Detection range:1 ppbto 50 ppmand50 ppb to 6,000 ppm
optional ※Working power supply:
AC220V ※Output mode: wireless
GPRS ※Detection accuracy: ±
5%FS ※Response time:
<15s ※
Installation method: wall mounted or vertical pipe installation ※6Service life: detector lamp tube
Month ※-20Working temperature:℃~50
℃ ※Working humidity:0~95%RH
(No condensation) ※630External dimensions:160××
515 mm ※Whole machine weight:
30KG