Jinan Blue Arrow Weighing Technology Co., Ltd
Home>Products>Vertical oil well pump
Vertical oil well pump
The vertical oil well pump is developed by Equan Pump Industry through the introduction of high-quality prototypes from West Germany. All technical in
Product details

1、 Introduction:

The SB type vertical oil well pump was developed by our factory in 2000 by introducing high-quality prototypes from West Germany. All technical indicators can reach the level of the prototype, and a series of derivative products have been developed based on the prototype for different liquid suction applications. This series of pumps is a lightweight tubular axial flow pump with high efficiency, easy use, and maintenance. This series of pumps is widely used in the chemical, petrochemical, fine chemical, dye chemical, environmental protection, water treatment, pharmaceutical, food and other sectors to pump different liquids. If used in flammable and explosive environments, our company's explosion-proof electric liquid pump can be selected. When using explosion-proof electric pumps (SB-3 and SB-4), the relevant provisions of CB38361-2 "Explosion proof Electrical Equipment for Explosive Environments" should be followed and explosion-proof plugs and sockets should be used correctly.

IIPerformance parameters:

The electric oil pump can be directly inserted into the material bucket (most suitable for steel buckets that comply with GB/325-1991 standards) to extract liquid from the bucket. It can transport various oils, corrosive chemicals, and other liquids. According to the properties of the liquid being transported, the wet part of the pump body can be made of materials such as aluminum alloy, stainless steel, 316 stainless steel, etc. The drive motor is equipped with various options such as single-phase standard motor, explosion-proof motor, and high-speed motor. According to the material and motor, the models can be divided into: SB-1, SB-2, SB-3, SB-3-1, SB-4, SB-5, SB-6, SB-7, SB-8 series aluminum alloy, stainless steel or explosion-proof type. We have detailed information available, please feel free to request it. This series of pumps can be selected according to explosion-proof and non explosion-proof areas. For use in explosion-proof areas, explosion-proof motors are configured, which are divided into three types of unit models. When the usage conditions include various flammable and explosive mixtures, the highest group level should be selected. This series of pumps can transport media such as acid, alkali, salt, oil, beverages, etc., and are widely used in chemical, petrochemical, fine chemical, dye chemical, environmental protection, water treatment, pharmaceutical, food and other departments. It is an ideal tool for transporting qi oil, m oil, cai oil, and light fuel in small and medium-sized oil fields, oil depots, refineries, gas stations, agricultural machinery stations, enterprises and institutions, fleets, vehicles and ships.

4、 Application and maintenance:
1. For new or long-term unused oil pumps, after opening the box, use a 500 volt megohmmeter to measure the J-edge resistance between all live parts and metal parts that may be touched. When approaching the working temperature, the resistance should not be lower than 7 megohms.
2. Before use, it is necessary to check whether each terminal is secure, and the grounding wire must be reliable and firm.
3. Check if the power supply voltage matches the rated voltage, and use it on a power supply that does not exceed or fall below 10% of the rated voltage.
4. When using an electric oil pump, do not damage the wires and prevent water and oil from entering the motor, switch, and electrical parts.
5. Non explosion proof electric liquid pumps are prohibited from working under conditions containing flammable and corrosive gases to ensure safe production and the normal operation of various electrical components.
6. If any abnormal noise is found during use, the machine should be stopped immediately, the cause should be checked, and only after trying to eliminate it can it be continued to be used.
7. It is not suitable to run the pump without air. Stop the pump immediately after suction is completed during use, as the motor of this pump can reach a no-load speed of about 10000 revolutions per minute. Otherwise, it will be worn out, the universal joint impeller, and in severe cases, the pump tube may be damaged.
8. Replace the electric brush: When the electric brush is worn out and cannot be used, it should be replaced immediately, otherwise it will damage the commutator and seriously burn out the motor.
9. Electric liquid pumps should be inspected regularly, usually at least once every three months. For those that are frequently used, they should be inspected once a month. During maintenance, they should be completely disassembled to eliminate internal dust and oil stains. If there is too much carbon buildup on the commutator, the surface of the commutator can be cleaned with alcohol. If there are damaged parts, they should be replaced with the same parts.
10. Please place it in a dry, clean, and non corrosive gas free environment when not in use.

5、 Random spare parts
1. Electric brush one set
2. A set of universal joints
3. One impeller

6、 Product Features and Applications
This product is suitable for flammable and explosive environments with explosion-proof capability of IIB level and ignition temperature not lower than T4 level. It has the characteristics of safety and reliability, reasonable structure, advanced technology, high efficiency, and easy maintenance.
This product complies with the national GB3836, 1-83 "General Requirements for Explosion proof Electrical Equipment for Explosive Environments" and GB3836, 2-83 "Explosion proof Electrical Equipment for Full Load Environments - Isolation Electrical Equipment" D "and GB3883. The provisions of 1-83 "Safety of Handheld Electric Tools". And through strict testing by the National Coal Mine Explosion proof Safety Product Quality Supervision and Inspection Center, it has obtained an explosion-proof certificate and is one of the tools used in flammable late explosion workplaces.
The above products have been tested by the explosion-proof inspection station according to 3836-. The 2-83 "Explosion proof Electrical Equipment for Explosive Environments - Explosion proof Electrical Equipment" D "standard has undergone strict testing and the results comply with the regulations for factory use explosion-proof (DI-IBT4) equipment.
The product is suitable for gasoline and other flammable and explosive materials in industrial and mining shops, chemical plants, drilling teams, warehouses, and other places. Using this pump ensures safety and improves efficiency, making it a reliable tool for use in flammable and explosive places.

7、 Safe usage instructions
1. Electric oil pump shall strictly follow GB3883 in addition to following this instruction. The relevant provisions of 1-83 "Technical Regulations for Safety Management, Use, Inspection, and Maintenance of Handheld Electric Tools".
2. SB oil pump can only be used within the rated value of ± 10% within the voltage range.
3. The oil pump should avoid the electrical level and the location where water and oil are installed. When installing this pump, do not damage the electrical level and avoid contact between oil, water and electrical parts such as motor switches.
4. To prevent sudden start-up of the SB electric oil pump, the switch should be in the "off" (i.e. pressed in) state before the power is turned on.
5. Do not abuse the power cord of the electric oil pump, and do not arbitrarily extend or replace the power cord. Do not scratch, cut, or crush the power cord while pulling it.
6. For the explosion-proof type, special attention should be paid to the explosion-proof surface of the explosion-proof parts when replacing the electric brush or repairing them, so as not to damage or scratch them. When repairing or replacing the electric brush, the motor should be opened to clean the internal cavity of carbon powder, oil corrosion, etc.
7. To use it correctly, the power cord of this pump does not come with a plug at one end, and the user can choose the appropriate plug themselves. There are two sides and three points to pay special attention to:
A, If using plugs and sockets in explosive and flammable areas, they must comply with explosion-proof regulations and be installed in normal areas far away from explosive and flammable sites. A 220V5A three pin plug can be used, with one long pin as the grounding pin.
B, Regardless of the type of plug used, it must be reliably grounded. The yellow green core wire at one end of the power cord is the grounding wire. After proper connection, it is also necessary to check whether there is electrical continuity between the metal casing of the pump and the contact pin. The resistance should not exceed 1 ohm.
8. Prohibited places: Cannot be used in special environments such as wet, snowy, and corrosive gas environments.
8、 Instructions for using E-Quan brand electric liquid pump:
1. Use specified voltage: The line voltage must not exceed ± 10% of the voltage specified on the nameplate of the pumping pump before use.
2. How to equip: After unboxing, assemble according to the structural diagram, connect the electric motor (1) and then connect the mobile phone (2) to integrate the pump body with the motor (3), and connect the water outlet pipe
3. Before use, check that all components are in good condition before starting up for use.
4. This pump is not suitable for idle operation. When in use, stop the pump immediately after suction is complete, otherwise it will accelerate the wear of impeller seals, bearings, and other components. It is also possible to wear out the pump tube, as the no-load speed of the pump motor can reach 10000 revolutions per minute.
5. Replace the brushes in a timely manner. When the brushes are worn out and cannot be used, they must be replaced in a timely manner (both brushes should be replaced at the same time). Otherwise, poor contact between the brushes and the commutator may cause ring damage, damage the commutator, and in severe cases, burn out the armature.
6. Do not use in the following situations. If insulation damage, cable sheath rupture, plug and socket cracking or poor contact, intermittent operation, severe sparks or other faults are found during use, repair should be carried out immediately when operating the motor casing. Do not use until repaired.
7. To prevent overload, in case of abnormal or reduced speed during use, the machine should be stopped immediately to check if there are any debris stuck in the impeller or if the motor has malfunctioned. When the pump brakes due to a problem, the power must be cut off immediately.
8. Use tools with care, and handle all coating pumps with care to avoid impact.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!