Unity 1400XT, 2600XT, and 2600XTR near-infrared analyzers from the United States
Near infrared analysis
Product details

1、 Application scope

The near-infrared method is used for rapid detection of raw materials, intermediates, semi-finished products, and finished products in agricultural breeding, oil processing, starch processing, biological fermentation, and food processing industries. It is suitable for all forms of samples: whole grains, powders, liquids, pastes, paddles, and pastes. In the starch processing and biological fermentation industries, Measurable samples include: raw materials such as corn, wheat, cassava, starch, corn protein powder, corn husk powder, corn germ, gluten solution, corn syrup, starch milk, extruded germ, intermediate products such as fructose, lactic acid, acetic acid, glycerol, semi-finished products, various fermentation liquids and finished products, by-products, etc.

XTR.jpg


two. Specification

1conform toNISTInternational standard, built-in integratedPCUsing patented technology for automatic wavelength scanning. Low temperature indium gallium arsenide detector with rotating top window configuration.

2Analysis time:10--60In seconds.

3Sample testing method: diffuse reflectionReflection and transmission.

4Working method: Non contact measurement through quartz window to avoid the influence of moisture loss(ISO12099).

5Wavelength range:

1400XTType:1400-2600 nm

2600XTType:1100-2600nm

2600XTRType:

6680-2600nm

7Absorption range:3.0AU

8Spectral accuracy: <0.005nmSpectral resolution:≤1nm(Completely based on

9NISTStandard)

10Wavelength accuracy:<0.02 nmBuilt in light source below5W, with a lifespan of up to

1110,000Hour by hour, no need for the annoyance of air-cooled filters, internal reference plates are installed to avoid damage from external methods and save costsIntegrated computer:17WindowsOperating system, built-inInch touchscreen computer,210/1005network card. Internal interface:An Ethernet interface,individualUSBPorts and printer ports, compliant

12LIMSStandard.Daily operationsUSCANSoftware patent software, capable of quantitative analysis and instrument calibration, easy to operate, with functions such as establishing, combining, and correcting calibration curves, power on self-test, result display, and abnormal sample labeling, upgradable. Super compatibility .

13Can achieve functions such as data transmission, instrument maintenance, remote diagnosis, etc., SupportMLR

14PLSChemical statistical models, supporting model conversion.1

15Sample size for testing:-300gEnvironmental temperature:

1-

40℃

3、 Core technical parameters of near-infraredwavelength accuracy

The absolute deviation needs to be less than+/-0.5 nmrefer toNIST

The following calibration standards require the use of

NIST

Tracer standard sample(Measure a set of specially calibrated constant standard peak values)Wavelength Repeatability

< 0.05 nm (1

standard deviation)

Absorbance AccuracyThe absolute deviation must be less than+/-

0.05AU

refer toNISTTracer standard

Absorbance accuracy

< 0.001 AU (1standard deviation)Photometric LinearitySlope:one+/- 0.02

Intercept:

+/- 0.02 (absolute value 0.0

)

1Regarding methodsPhotometric noise

2RMS < 0.000020 AU contrast4、 Hardware performanceMonochromator: pre spectral grating monochromator, holographic scanning gratingWavelength range:1400-2600

1100-2600680-2600nmContinuous spectrum.Wavelength accuracy<0.02nm

, in accordance withNISTInternational calibration standards are adopted for instruments

3NISTDirectly calibrate the wavelength specified by official standards.

4Wavelength accuracy< 0.005nm 20resolution≤1nmFull spectrum range absorbance noise

μAu20680-2600 nm

680-1100nm15Absorption noise<μ

Au1100-2500nm15Absorption noise<μ

5Au1400-2500nm

6Absorption noise<1920μ AuData sampling interval:1nm

7Number of detected wavelengths:individual680-2600nm

8

9Open rotating top window configuration, non-contact measurement through quartz window to avoid the influence of moisture loss, in compliance with

10ISO120992standard1.1Large diameter sample cup increases the sample detection area and enhances sample representativeness.5The free combination detection system can be upgraded at any time to detect samples in different states, including particles, powders, liquids, paddles, pastes, and pastes, without the need for complex detection accessories.

11Provide

A lamp (built-in instrument)

One, randomly configuredA). Free backup lights will be provided within the year.Provide users with free upgrade models, add models, and establish models for life. No additional cost is required.5、 Software section1

2The instrument can be configuredUScanDaily operation software and

3UCalChemometric modeling and processing software.UScanSoftware functions: data collection, automatic analysis of calling models, viewing of spectra and data, instrument calibration, report printing, user settings and management, and establishment of operator usage permissions.

4UCal Chemometric modeling and processing software:UCalThe patented software integrates multiple modeling methods and powerful data preprocessing functions, with powerful model editing, calculation, evaluation, optimization and other functions, which can easily and quickly establish and calibrate models.Model transfer and maintenance:UCal

5The software can convert other system databases to

UnityThe company'sNIRIn the system, model porting can be easily achieved through unique spectral matching operations. During later maintenance, samples can be directly added to expand the database, improve the model gradient, and enhance the adaptability, stability, and accuracy of the model.Modeling methods and principles:8

Spectral preprocessing method: usually using standard normalization processing(SNV andDetrend)First order differentiation,Point smoothing processing, etc.Chemometric methods:There are mainly multiple linear regression(MLR)Principal Component Analysis(

6PCA)Principal Component Regression(PCR

7)Partial least squares method(PLS)Wait.

, Optional

1CommUnity 1

2Cloud based near-infrared network control software allows administrators to create detection products (scanning methods, calibration models, and product settings). The instrument automatically receives product settings from the network server, and samples and diagnostic data are automatically synchronized and transmitted to the server to ensure complete consistency in network instrument detection, without the need for each sub machine to collect samples separately and establish models. 1, Optional

3CommUnity17Cloud based near-infrared network control software can achieve network settings, monitoring, and reporting from any location and instrument, allowing remote management of all instruments (networks) within the group. It can combine graphics, charts, and waveforms of data from multiple areas to create advanced reports and graphics. Different permissions can be set to display and process information that can be accessed and controlled by different permissions. Computers, tablets, and mobile phones can all log in and operate the display interface. 16、 Configuration Description

HostSample Rotating Diskindividual 1Configuration

5Built in computer with high-resolution touchscreen displayindividual4Specialized operating software 1UScan

6coverMulti purpose sample base(3Suitable for multi form sample detection

7) 1individual

81TAS