The UV aging test chamber is a type of aging test equipment that simulates light exposureSpecially simulating the destructive effects of ultraviolet radiation on products in the sun, it only takes a few days or weeks, and the equipment can reproduce the damage that takes months or years outdoors. Check whether the product has discoloration, decreased chromaticity, powdering, cracking, blurriness, decreased brittleness, oxidation, and other phenomena. At the same time, it can also reproduce the damage caused by rainwater and dew. The UV aging test chamber conducts the test by exposing the test sample to controlled cycles of sunlight and moisture, while increasing the temperature. By conducting simulated artificial climate aging acceleration tests on different material products, we compare their resistance to humidity and heat, outdoor climate performance under light exposure, and evaluate their quality.
Widely applied in various industriesFor example, coatings, inks, paints, resins, plastics, printing and packaging, adhesives, automotive and motorcycle industries, cosmetics, metals, electronics, electroplating, pharmaceuticals, etc.
TG-The 1023A UV aging test chamber is suitable for the following standards:
1:GB/T16585-1996 Test Method for Artificial Climate Aging of Vulcanized Rubber (Fluorescent UV Lamp)
2:GB/T14522-2008 Methods of artificial climate aging for plastics, coatings, and rubber materials used in the mechanical industry
3:GB/T16422.3-2014 Laboratory light source exposure test methods Part 2: Fluorescent ultraviolet lamps
4: GB/T 16422.1-2006 Plastics Laboratory Light Source Exposure Test Method Part 1 General Principles
5:ISO 4892-3: 1994 Plastics - Test methods for exposure to laboratory light sources - Part 3: Fluorescent ultraviolet lamps
6: GB/T23987-2009/ISO 11507: 2007 Artificial Climate Aging Exposure (UV) and Other Standards for Paint and Varnish Coatings
TG-1023A UV aging test chamberProduct Features:
1: The new generation of UV aging test chamber produced by Taigui Instrument has undergone significant technological reforms in the box structure, control technology, and operation, making it more reliable and easier to maintain.
2: The control system adoptsColor touch screen display in both Chinese and EnglishButton based operation, with a simpler and more elegant appearance, and simple operation settings.
3: UV aging box equipped with: SD card storage, USB output, computer connection for printing, large cabin with paperless recording and other optional features.
5: UV is designed entirely from the user's perspective, making it easy to operate, safe, and reliable.
6: The installation thickness of the test piece can be adjusted, and the installation of the test piece is fast and easy.
7: The upward rotating door does not hinder users from operating the device and only occupies a small space.
8: The equipment has casters for easy mobility, and casters are standard accessories.
9: Calibration with an illuminance calibrator can extend the lifespan of the lamp tube
10: Box processingUsing CNC machine tools for processing and shaping, the appearance is beautiful and elegant, and the operation is easy. housinguseHigh quality carbon steel plate.Phosphating electrostatic spraying treatmentOr (optional)SUS304 stainless steel matte surface line hairline treatment. All internal materials are made ofSU304 high-grade stainless steel material.
11: Remote fault diagnosis, as well as self checking function of the boot device.
TG-Technical parameters of 1023A UV aging test chamber:
Equipment model |
Studio size(mm) longX width X height |
External dimensions(mm) longX width X height |
light source |
temperature range |
Total power of the power supply |
|
TG-1023A |
1200X400X500 |
1300X500X1400 |
UVA(340) |
RT+10 ℃~70 ℃ adjustable |
220v/4.5kv |
|
TECHNICAL INDEX |
Temperature range:RT+10℃~70℃ |
|||||
Humidity range:≥95%RH | ||||||
Temperature uniformity:≤± 2.0 ℃ (unloaded, constant state) | ||||||
Temperature fluctuation:≤± 0.5 ℃ (unloaded, constant state) | ||||||
Blackboard temperature:50℃±3℃~70℃±3℃ | ||||||
Condensation temperature:RT+10℃~70℃ | ||||||
Range of irradiance:0.35~2.0w/㎡(Automatic dimming, irradiation intensity display) | ||||||
Rain time: Rain time1-9999H (adjustable) | ||||||
Spray circulation system |
Nozzle: Multiple nozzles on both sides of the studio |
|||||
Pressure:0.12~0.15Mpa | ||||||
Spray cycle: Spray cycle12min~102min 5 adjustable | ||||||
Spray time setting:0-9999 hours and 59 minutes interval (interrupted) | ||||||
Composed of components such as water pump, time relay, nozzle, etc. Rain cycle adjustable (recommended to add deionized water) | ||||||
fluorescent tube |
The emission spectrum energy of UVA lamps is mainly concentrated between 315nm and 400nm wavelengths. 340 (indoor) |
|||||
AmericaQ-LAB: Lifespan: ≥ 1500 hours, with a total of 4 wires in one row, (front and rear design) 40W (only) | ||||||
Parallel center distance of lamp tube:70mm |
Distance between the test sample and the surface of the lamp tube:50±2mm |
|||||
sensor |
temperature |
A-grade platinum resistor A (PT100) |
||||
heater |
Fin type stainless steel heating system. |
|||||
radiometer |
UV-A ultraviolet radiometer |
|||||
standard test piece |
48 pieces (75x150mm), 50 pieces (75x150mm) |
|||||
Usage environment |
Temperature:5 ℃~35 ℃, relative humidity: ≤ 85%RH |
|||||
Cabinet material |
Outer box: Cold rolled sheet with electrostatic sprayingthickness1.5mm |
|||||
Inner box:304 # mirror stainless steel, thickness 1.2mm | ||||||
Safety protection |
Over temperature protection, leakage protection, under phase and phase loss protection, overcurrent protection, fast fuse, compressor high and low voltage protection, compressor overheating protection, compressor overcurrent protection, line fuse and fully sheathed terminal, grounding protection |
|||||
pour |
Tai Gui Company can customize products according to customer requirements. |