SharpEyeTM20/20Land20/20LBUV/IR Flame Detector (BIT)
·Using a UV sensor that is insensitive to sunlight and an additional narrowband infrared sensor,
·It can provide excellent detection sensitivity and improve immunity to false alarms (light blindness).
·Provide high-speed and high-performance flame detection and alarm for military and industrial industries.
·Can detect combustion flames of hydrocarbons, such as hydrogen, hydroxyl compounds, as well as metal and inorganic combustion flames.
·Monitor narrowband spectral frequencies of ultraviolet and infrared radiation.
·The sensor ensures a high sensitivity to the emission spectrum frequency generated by flames, while also having immunity to the emission spectrum frequency generated by non combustible micro smoke.
·The UV sensor integrates logic circuits to prevent false alarms caused by sunlight radiation.
·The detection range of the IR sensor is 2.5~3.0 microns. The detector analyzes the frequency, brightness, and duration of the signals received by UV and IR sensors, and any sensor can trigger an alarm upon receiving the flame emission spectrum.
characteristic
UV/IR dual spectral detection
• High speed flame detection
• 20 second response to dark signals
• User settings function
• High error alarm immunity (light blind)
• Automatic or Manual Calibration Function (BIT) - LB
Standard 4-wire connection
4-20mA or 3-4 wire output
• Minimum average time between failures 100000 hours
• 3-year warranty period
FM, CSA, ATEX/Genelec&Host R certification
Basic technical parameters
Spectral range
|
VU: 0.185-0.260 microns
|
IR: 2.5~3 microns
|
Detection range
|
Gasoline 50ft (15m)
Heptane 50ft (15m)
95% alcohol 37ft (11m)
Diesel 37ft (11m)
|
JP4 37ft(11m)
37ft (11m) of kerosene
Methane 15ft (4.5m)
(Propane) 15ft (4.5m)
|
reaction time
|
5 seconds (standard)
|
Adjustable delay
|
Maximum 30 seconds (20 seconds optional)
|
Monitoring scope
|
Vertical 90oLevel 90o
|
Self checking function
|
Manual or automatic self-test
|
Temperature requirements
|
Working temperature: - fortyoF(-40oC)~160oF(70oC)
Working temperature (optional): - fortyoF(-40oC)~185oF(85oC)
Storage temperature: - sixty-fiveoF(-55oC)~185oF(85oC)
|
humidity
|
95%
|
Electronic technical parameters
working voltage
|
18-32VDC
|
Working current
|
Standby mode: 150Ma (maximum)
Alarm status: 200Ma (maximum)
|
Cable conduit
|
2 ╳ 3/4 ″ -14NPT or 2 ╳ M25 ╳ 1.5mm ISO
|
Circuit protection
|
Complies with MIL-STD-1275A standard
|
electromagnetic compatibility
|
EMI/RFI protected CE Marked
|
output
Relay output
|
Alarm: - 2A @30 VDC 0.5A @250 VAC
Failed: - 5A @30 VDC/250VAC
Failed relay output: normally closed; Other: Normally on
|
4-20Ma
|
Fault:
BIT Fault:
Normal:
Infrared (IR Detection):
UV Detection:
Warning:
Alarm:
Resistance loop:
|
0
2mA
4mA
8mA
12mA
16 mA
20 mA
100-600 Ohm
|
+0.5 mA
±10%
±5%
±5%
±5%
±5%
±5%
|
physical property
External dimensions
|
4.7" x 5.2" x 5.2" (120 x 132 x 132 mm)
|
weight
|
Aluminum: 8.1Lb (3.7 Kg)
Stainless steel (St. St 316L): 14.3Lb (6.5 Kg)
|
Applicable environment
|
Compliant with MIL-STD-810C standard. Applied to high humidity, high salt, vibration, mechanical vibration, high and low temperature environments.
|
Protective performance
|
IP66 and IP67 per En60529
|
NEMA 250 6P
|
authentication
ATEX/Cenelec
|
EX II 2G,EExd IIB+H2 T5(70°C)EX II 2G, EExde IIB+H2 T5 70°C)
|
FM / CSA
|
Class I Div. 1, Groups B, C & D Class II Div. 1, Groups E, F & G
|
GOST R
|
1ExdIIBT5/H2
|
|