Liaoyang Automation Instrument Group Co., Ltd
Home>Products>UHZF series float type magnetic float level gauge
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13504206580
  • Address
    No. 12 Guanghua Street, Hongwei District, Liaoyang City, Liaoning Province
Contact Now
UHZF series float type magnetic float level gauge
The UHZF float type magnetic float level gauge combines the characteristics of a magnetic float level gauge and a float level gauge. It is mainly used
Product details
Overview:

The UHZF float type magnetic float level gauge combines the characteristics of a magnetic float level gauge and a float level gauge. It is mainly used for measuring and controlling the liquid level or boundary of normal and low-pressure storage tanks, and is particularly suitable for situations with a large measurement range, high viscosity, and strong corrosion. If a liquid level alarm switch and a remote transmitter are installed on the instrument, remote control, automatic detection, and recording can be achieved.

Structural principle:

This liquid level gauge has a floating ball that floats up and down with the liquid level inside the container. It drives the heavy hammer to slide up and down through a rope and pulley assembly to flip the indicator magnetic flap, thereby continuously indicating the liquid level of the medium inside the container. According to the connection method between the float and the rope, it is possible to achieve forward and reverse reading of the liquid level gauge indication. Positive reading means that when the liquid level rises, the heavy hammer of the liquid level gauge slides from bottom to top, and the zero position of the indicator scale is at the bottom; Reverse reading means that when the liquid level rises, the heavy hammer of the liquid level gauge slides from top to bottom, and the zero position of the indicator scale is on top. Large measurement range, clear indication, convenient observation, intuitive reading, and no blind spots in the entire measurement process.

Main technical parameters

◆ Operating pressure:- 0.1~1.6MPa
Operating temperature: 0~200 ℃
Measurement range: 2000~20000mm
◆ Medium density: generally ≥ 0.45g/cm3
◆ Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
Accuracy: ± 10mm
◆ Connection flange standard: HG/T20592-2009 DN40
Designated by the user (various standard flanges such as GB, HGJ, ANSI, SH, DIN, JIS, etc. can be made according to user requirements)

Usage conditions

model

Structural characteristics

Applicable conditions

Liquid receiving material

Installation form

Operating temperature ℃

Operating pressure MPa

Medium density g/cm3

UHZF-5

Top mounted buoy type

0~200

≤1.6 0.45~2.0

stainless steel

Top mounted

0~200

≤1.6 0.45~2.0
UHZFZ-5

Top mounted blocking buoy type

stainless steel Top mounted
Structural schematic diagram

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!