Overview:
|
The UHZE series anti frost magnetic float level gauge is mainly used to measure the liquid level or boundary of low-temperature and frost prone media in pressurized containers. If a liquid level alarm switch and a remote transmitter are installed on the instrument, remote control, automatic detection, and recording can be achieved. According to the structure of frost prevention, it can be divided into UHZE ordinary frost prevention type, UHZE-7 side and top mounted frost prevention type, and UHZ-EK vacuum frost prevention type.
| Main technical parameters: |
◆ Operating pressure: ≤ 32.0MPa
Operating temperature:- 196~0℃
Measurement range: 300~6000mm (extra long liquid level gauges can also be made according to user needs, and extra long ones can be made in sections due to inconvenient transportation.)
◆ Medium density: 0.45~2.0g/cm3
◆ Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
Accuracy: ± 10mm
◆ Anti frost board material: organic glass, height determined by temperature
◆ Connection flange standard: HG/T20592-2009 DN20, DN150 (for side and top mounted)
Designated by the user (various standard flanges such as GB, HGJ, ANSI, SH, DIN, JIS, etc. can be made according to user requirements)
| Usage conditions: |
|
model |
Structural characteristics |
Applicable conditions |
Liquid receiving material |
Installation form | ||
|
Operating temperature ℃ |
Operating pressure MPa |
Medium density g/cm3 | ||||
|
UHZE |
Frost proof type |
-196~0 |
≤32.0 | 250 |
stainless steel |
Side/Top/Side Bottom/Top Bottom |
|
-196~0 |
≤32.0 | 0.45~2.0 | ||||
| UHZE-7 |
Side top mounted, frost resistant type |
stainless steel | Side top installation | |||
| UHZE-K | Vacuum anti frost type | -196~0 | ≤32.0 | 0.45~2.0 | stainless steel | Side/Top/Side Bottom/Top Bottom |
Scope of application:
|
The UHZE ordinary frost proof type adds a frost proof plate to the level gauge indicator. Frosting on the body does not affect the operation of the level gauge, and the liquid level or boundary can be clearly observed from the frost proof plate.
The indicator of the UHZE-7 side top mounted anti frost liquid level gauge is installed above the measurement range, avoiding the frost area of the body, and can achieve the purpose of anti frost without adding a frost plate.
UHZEK vacuum anti frost type is a type of device that adds a layer of vacuum cylinder to the measuring tube of the liquid level gauge to insulate the measured medium from the outside world, so that the entire body will not frost and can achieve the purpose of anti frost without the need for an anti frost plate.
| Structural schematic diagram: |


Overview: