1、 Instrument Introduction:
Turner, USATurner DesignsThe instrument company is a research and production company for hydrocarbon analyzers and water oil monitoring instruments, with mature technology and rich experience in the field of water oil analyzers.
TD-120It is a cost-effective online water oil monitoring device on the market, which has high sensitivity to oils such as fuel, lubricating oil, and hydraulic oil, with alarm and detection limits below1ppmAt the same time, it is equipped with a chamber cleanliness monitoring function, which can easily verify the cleanliness of the water oil monitoring device.
TD-120useLEDAs a light source,LEDThe lamp source has a long lifespan, which can minimize the impact of light source drift during the service life of the water oil monitoring instrument.TD-120The circulation pool is equipped withSmart SensorIntelligent sensor, sturdy and durable, carrying all calibration data. If the circulation pool needs to be replaced, local technicians can easily operate it on site.
TD-120The chamber cleanliness monitor is the second * sensor inside the instrument. There is no other water oil monitoring device on the market that has this feature. It can inform the operator that the circulation pool is in a clean state and subsequent measurements are effective. If cleaning is required, the chamber cleanliness monitoring function can prove that the cleaning work has been completed. At the same time, users can also confirm calibration using standard solutions through the instrument's built-in injection port.
TD-120Provide real-time response, adapt to process changes, and the instrument's full-scale response time only needs to be less than10In seconds. The instrument is equipped with standard4-20mAThe signal output can indicate the concentration of oil and has4A relay is used for process and system alarm functions.
TD-120The humanized design can be easily and quickly installed and debugged by local technicians.
Meet the standards:
Comprehensive Wastewater Discharge StandardsGB 8978-1996》
Technical Specification for Monitoring Total Discharge of Water PollutantsHU/T92-2002》
Marine Monitoring StandardsGB17378.3-1998》
2、 Technical parameters:
l Application: Steam condensate water, boiler feedwater, cooling water, water intake protection, water source protection, process optimization
l Applicable hydrocarbons: diesel, fuel oil, crude oil, gasoline, jet fuel, lubricating oil, phenol, heat transfer fluid, aromatic compounds(BTEX)
l Measurement range: LowPPBlevel- 6000PPMThe range depends on the solubility of the oil in water and the background fluorescence
l Size: Wall mounted, long508mmX width140mmX high406mm
l Weight:10.9kg(24 lbs)
l Local color display screen:PPM,PPBOr the original fluorescence value
l Control: External touch keyboard control, allowing viewing of events, history, and maintenance records; Built in tablet for configuration and calibration settings
l Power requirements:100-240VAC 50/60Hz,1.3AValue, single-phase, neutral or live wire (inrush current must not exceed)40AValue)
l signal communication:4-20mASignal output, optional circuit power supply or instrument self power supply; Optional:HARTcommunication protocol
l Alert:4Dry contact alarms that can be set by individual users: early alarm, high concentration alarm, system alarm, chamber cleanliness condition alarm, high temperature alarm
l Pipeline requirements: inlet pipe1/4”, reflux pipe1/4”, flushing tube1/4”
l Sample inlet pressure:10-100psig(69-690 kPag)For higher pressure, please consult the factory
l Sample temperature:0-50°C(32-122°F)For higher temperatures, please consult the factory
l Environmental operating temperature:0-55°C(32-131°F)
l Flow rate: Limit value:0.03-0.79US gallon/Minutes(0.1-3rise/Minutes)
Suggested value:0.26-0.52gallon/Minutes(1-2rise/Minutes)
There are also sample pumps available for selection
l Operating principle: UV fluorescence method
l Response time: default3Seconds (user adjustable, as low as)0.5Seconds), continuous reading
l authentication:EN 61010-1:2010reachEN 61326-1:2013
CAN/CSA-C22.2 No.61010-1:2012 + UPD ******:2015-07
3、 Applicable oils:
1. condensate oil
2. crude
3. diesel oil
4. Heavy fuel
5. jet fuel
6. kerosene
7. lubricant
8. phenol
wait a minute
4、 Application areas:
1Oil leakage monitoring of boiler feedwater and condensate water
2Monitoring of oil leakage in circulating cooling water
3Oil monitoring in the water of the dam pit of a hydroelectric power station
4Production of water/Detection of crude oil content in industrial wastewater
5Monitoring of Hydrocarbons in Ship and Warship Cabin Sewage
6Environmental emergency monitoring
7Other oil testing fields.
Turner UV Online Water Quality Monitor
Turner UV Online Water Quality Monitor