TJ-2A/L0107-2A is a single channel push-pull mode microinjection pump. Precise, compact, structurally compact, easy to install, and easy to operate. Standard injectors with μ L specifications can be installed, with precise stroke control and a wide range of line speeds (7.9 μ m/min -79.4mm/min) to meet the needs of different users. The vertical installation structure can be conveniently used in conjunction with biological instruments such as micro manipulators and stereotaxic brain locators, and is widely used in various fields of biological experiments.
Technical specifications of push-pull mode single channel microinjection pump
Maximum travel: 70mm
Applicable injector: 5-1000 (μ l)
Linear speed range: 7.9 μ m/min to 79.4mm/min
Adjust resolution: 7.9 μ m/min
Travel resolution: 0.165 μ m
Rated linear thrust>20N
Setting method: Combining film buttons with encoding switches for setting
Control accuracy: When ≥ 30% full stroke, the control error is ≤± 0.5%
Display mode: 128 × 64 dot matrix LCD display
External control interface: start stop control, fast forward control, fast backward control
Communication interface: RS485
Applicable power supply: AC100V-220V or DC12V
Power consumption<10W
Working environment: Temperature range of 0-40 ℃, relative humidity<80%
Controller dimensions: 170 × 108 × 65 (mm)
Controller weight: 0.8kg
Dimensions of the actuator: 180 × 46 × 78 (mm)
Weight of actuator: 0.6 Kg
Protection level: IP21
Features of push-pull mode single channel microinjection pump function
Working modes: infusion, extraction, infusion before extraction, extraction before infusion, continuous five modes to choose from
Custom sampler: capable of storing four user-defined inner diameter values
Linear thrust output: Full range>20N
Power off memory function: After powering on again, you can choose whether to continue working according to the state before power off
Signal output function: Two OC gate switch signals are output to indicate the start/stop and directional status of the constant current pump
Flow correction function: Obtain more accurate liquid volume through correction operation
Fast forward (rewind) function: Full speed infusion or extraction of liquid
Push pull mode single channel microinjection pump Other parameters
Constant flow pump model |
Sample injector specification (μ l) |
Injector inner diameter (mm) |
Effective travel distance (mm) |
Reference flow range |
Injector material |
Weight (kg) |
(Product Code) |
(nl/min-μl/min) |
|||||
TJ-2A/L0107-2A |
5 |
0.35 |
51.97 |
0.764-7.64 |
Glass sampler |
Executing Agency 0.6 |
-503111 |
10 |
0.5 |
50.93 |
1.559-15.59 |
Controller 0.8 |
|
-503011 |
25 |
0.8 |
49.74 |
3.989-39.89 |
|
|
|
50 |
1.1 |
52.61 |
7.544-75.44 |
|
|
|
100 |
1.6 |
49.74 |
15.96-159.6 |
|
|
|
250 |
2.3 |
60.17 |
32.98-329.8 |
|
|
|
500 |
3.25 |
60.27 |
65.85-658.5 |
|
|
|
1000 |
4.61 |
59.91 |
132.5-1325 |
Tags:    Single channel microinjection pump  Constant flow pump