Shanghai Zhongrong Yidian Co., Ltd
Home>Products>Three phase electric energy meter calibration device (intelligent type)
Three phase electric energy meter calibration device (intelligent type)
Three phase electric energy meter calibration device (intelligent type)
Product details


Device level

0.05/0.1 level;

Device structure
Integrated, split, and mobile;

Table number
3 epitopes, 6 epitopes, 8 epitopes, 12 epitopes, 16 epitopes, 24 epitopes, 32 epitopes, 48 epitopes;

Main features
1. The complete set of equipment consists of a three-phase programmable power source (linear source), a three-phase multifunctional standard energy meter, an error calculator (embedded), a pulse and photoelectric signal receiving and processing system, a multi winding isolation PT (optional), a multi meter testing rack (hanging meter rack), a time base frequency meter, a 485 communication interface and testing line (embedded), device control software, a computer and peripherals (printer, barcode scanner, etc.);
2. The device has three structures: integrated, split, and mobile. All are made of high-quality specialized aluminum magnesium alloy profiles, which are lightweight, sturdy, beautiful, and durable. The calibration workstation can meet the requirements of national regulations from 3 to 96 meters (the standard types of calibration workstations include: 3 meters, 6 meters, 8 meters, 12 meters, 16 meters, 24 meters, 32 meters, and 48 meters);
3. The supporting software for the device can be customized according to user requirements and habits by module. The software is easy to operate and can preset calibration schemes for electric energy meters (including basic error measurement, creep and start-up tests, positive and negative active and reactive energy errors, as well as standard deviation testing, 24-hour variation testing, etc.) and influence quantity testing schemes. Automatically calibrate the electric energy meter according to the selected calibration plan. The calibration results can be stored, queried, and printed in various ways at any time for measurement data. And network management can be implemented according to user requirements;
4. Function of electric energy meter influence test: PC verification can set the influence test plan according to the requirements of the regulations, and complete tests on frequency influence, voltage influence, short-term voltage interruption influence, and gradual voltage change influence. And it can conduct harmonic impact tests. The PC verification can set the harmonic impact test plan according to the regulations. The voltage and current can output 2-21 standard harmonics separately or simultaneously, odd harmonics, even harmonics, sub harmonics, and harmonic components can be set;
5. The device can also perform multi constant verification and constant verification: PC verification can simultaneously verify multiple energy meters with the same current, voltage, and wiring method, but different constants and levels, and verify the constant rows of the energy meters. In the scheme setting, after setting the number of verification cycles for the first table, the remaining tables will automatically adjust according to a constant and ensure consistency in verification time;
6. The device also has the function of testing the indication error of the electric energy meter and the combination error of the meter;
7. The device has the ability to detect the time function of the electric energy meter, which can detect the daily timing error, time period switching error, demand cycle error, demand indication error, and combination error of the multifunctional electric energy meter

8. The device has the ability to detect the communication function of the smart energy meter, and can detect the communication function of the 485 interface of the smart energy meter
9. The device has the ability to detect the up and down channels of the smart energy meter, and can detect the carrier communication interface, cost control interface, multifunctional interface, etc. of the smart energy meter;
10. The device has a smart energy meter confidentiality verification function (the encryption machine is self equipped by the user)

11. The device can automatically complete the calibration and issue a testing report through a computer preset calibration plan;
12. The device is equipped with standard high and low frequency power pulse output interfaces for standard energy meters, to facilitate weekly inspections of the device;
13. The device has fast protection and alarm functions, automatically protecting and alarming in case of voltage short circuit or current open circuit

14. The device supports barcode input to improve input efficiency (requires barcode scanner support)
15. It has manual operation function (requires support from Android system terminal - tablet or mobile phone)
16. Can be equipped with zero line current testing function (optional)
17. Can be equipped with a power consumption tester to achieve power consumption measurement function of the electric energy meter (optional)
18. Can be equipped with a multi serial communication system to achieve parallel communication between the computer and the tested meter (optional)
19. Can be equipped with tilt influence test (optional).

Product Usage
1. Verify the basic error (accuracy) of electromagnetic and electronic three-phase energy meters;
2. Verify the creep and starting errors of electromagnetic and electronic three-phase energy meters;
3. Verify the standard deviation and 24-hour variation of electromagnetic and electronic three-phase energy meters;
4. Verify the measurement errors and combination errors of electromagnetic and electronic three-phase energy meters;
5. Detect the changes caused by voltage, frequency, harmonics, reverse phase sequence, voltage imbalance and other influencing factors of electromagnetic and electronic three-phase energy meters;
6. Verify the constants of three-phase electric energy meters, both electric and electronic;
7. Check the power parameters of three-phase multifunctional energy meters and smart energy meters;

8. Check the daily timing error and time period switching error of three-phase multifunctional energy meters and intelligent energy meters;
9. Detect the 485 communication interface of three-phase multifunctional energy meters and intelligent energy meters;
10. Detect the carrier communication interface of three-phase multifunctional energy meters and intelligent energy meters;
11. Check the multifunctional interface of the three-phase intelligent energy meter;
12. Verify the confidentiality of the three-phase intelligent energy meter (requires hardware support from the encryption machine).
Technical indicators:
Instrument configuration details
1. Standard configuration details:
1) One three-phase programmable power source (linear source, 0.1 or 0.05 level optional)
2) One three-phase multifunctional standard energy meter (0.05 level)
i. Factory inspection report
Ii. Manual 1 volume
Iii. One copy of certificate of conformity
Iv. One aluminum alloy box
v. 1 high-frequency test line
Vi. One power cord
3) 1 test meter rack (hanging meter rack)
4) One set of error handling system (embedded)
5) 485 communication detection interface (embedded)
6) 1 set of time-based frequency meter
7) 1 set of current testing wires (not included when configuring customized junction boxes)
8) 1 set of voltage testing wires (not included when configuring customized junction boxes)
9) 1 pulse signal line (not included when configuring customized junction boxes)
10) 1 data communication cable
11) 1 power cord for the device (standard three-phase four wire T4-25A plug)
12) 1 set of operation and data processing system for electric energy meter calibration device (intelligent version)
13) 1 computer (domestic mainstream brand, specifications)
14) 1 printer (domestic mainstream brand, specifications)
15) 1 manual (including 1 operation manual, 1 simple maintenance manual, and 1 electronic version)
16) 1 copy of factory test report
17) 1 certificate of conformity
18) 1 copy of packing list
19) Packaging method: inner paper and outer wooden box (rainproof)
20) Transportation method: Automobile transportation
21) On site installation and debugging training (3 days/time, including two sets of installation reports)

2. Select configuration details:
1) 1 manual keyboard (tablet)
2) Photoelectric sampler (domestically produced, matched according to the meter position)
3) 1 set of multifunctional meter test extension leads (compatible)
4) 1 set of multi-functional meter voltage testing cable (compatible)
5) 1 set of computer desk and chair (domestic)
6) Barcode scanner gun (domestic)
7) Multi winding isolation PT (for compatibility with single-phase energy meter calibration)
8) Multi port hub (domestically produced, specifications determined by meter number)
9) 1 power consumption tester (domestic)
10) GPS signal antenna (line length 30 meters)
11) 1 set of encryption machine (used for smart meter confidentiality verification)