Single phase MODBUS meter, three-phase MODBUS meter, MODBUS meter model, single-phase multifunctional power meter, single-phase rail type meter, three-phase rail type meter, single-phase rail type RS485 energy meter, Taiyuan, Datong, Xinzhou, Yangquan, Changzhi, Jincheng, Shuozhou, Jinzhong, Yuncheng, Linfen, Lvliang, Xi'an, Xianyang, Tongchuan, Yan'an, Baoji, Weinan, Hanzhong, Ankang, Shangluo, Yulin single-phase rail with threading type energy meter, single-phase wireless communication meter, single-phase multi rate energy meter, three-phase dual rate energy meter
1、 Overview
The rail mounted electric energy meter is suitable for installation in compact electric energy metering cabinets or cabinets. It adopts MODBUS interface, which facilitates the connection with PLC and other equipment to upload electric energy related data, and facilitates the automation management of electricity consumption. An automatic meter reading system can also be formed by communicating with a microcomputer through an RS485 communication interface. Rail mounted energy meters are the latest generation of miniaturized intelligent energy meters launched in recent years. This series of electric energy meters has the advantages of small size and easy installation, as well as extremely high accuracy and good anti electromagnetic interference performance, fully meeting the relevant technical requirements of level 1 and level 2 electronic energy meters in the national standards DL/T614-1997 and GB/T17215-2002. The model of the three-phase rail mounted electric energy meter is DTS2026-N, which adopts LCD display. The enhanced version can be set for clock, rate period, etc., and has pulse output function;
2、 Technical indicators
Project indicators
DDS2026-N single-phase energy meter DTS2026-N three-phase energy meter
Accuracy level active level 1 active level 1 (optional 0.5 level)
Reference voltage Un single-phase: 220V three-phase four wire: 3 * 220V/380V
Current specifications 1.5 (6) A, 5 (20) A, 10 (40) A, 20 (80) A 1.5 (6) A, 5 (20) A, 10 (40) A, 20 (80) A
Participation frequency 50-60HZ 50-60HZ
Normal operating voltage range: 0.7UN-1.2UN Normal operating voltage: 0.7UN-1.2UN
Working temperature -10~+45 ℃ Working temperature -10~+45 ℃
Power consumption voltage circuit: ≤ 5VA
Current circuit:<4VA/phase (at maximum current) Voltage circuit: ≤ 5VA
Current circuit:<4VA/phase (at maximum current)
Clock accuracy ≤ 0.5S/D ≤ 0.5S/D
Pulse output parameters Pulse width: 80ms ± 20ms Passive output, external current:+5V~24V Pulse width: 80ms ± 20ms Passive output, external current:+5V~24V
Communication protocol MODBUS-RTU (other customizable) MODBUS-RTU (other customizable)
Dimensions 76 * 89 * 74 (mm) 126 * 89 * 74 (mm)
3、 Functional Features
Three phase rail energy meter
Measurement:
1.1 Measure positive active energy and have automatic recognition and indication of power direction
1.2 Total, peak, flat, and valley electrical energy shall be stored separately and saved in the corresponding storage units
1.3 The electricity meter can store data for 3 months, and the default frozen transfer date for electricity is 24:00 at the end of the month (frozen at the end of the month)
1.4 After power failure, all stored data will not be lost and can be maintained for more than 10 years
2 Clock and Time Rate:
2.1 Internal hardware clock, clock error within 0.5S/day
2.2 Programmable settings for peak, off peak, off peak, and off peak rates, with a minimum interval of 1 minute between 8 time periods per day
3 Display:
3.1 7-bit wide temperature LCD display
3.2 Real time data rotation display, with a cycle display time of 4 seconds
3.3 Electric energy pulse indicated by red LED
3.4 Three rates are indicated by green LED during peak, off peak, off peak, and off peak periods
3.5 Output:
3.6 Active energy pulse output, used for meter calibration and energy collection
4 Communication:
4.1 Used for parameter setting and meter reading
4.2 RS485 communication interface, MODBUS-RTU communication protocol
5 Programming:
5.1 Programming settings are performed through the upper computer
5.2 Time and Date Setting
5.3 Meter Address Setting
5.4 Rate Period Setting
5.5 Battery Bottom Reset Setting
4、 External dimensions