Ningbo Sida Testing Equipment Co., Ltd
Home>Products>Three box type hot and cold shock test box, rapid temperature change test box
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18958207418
  • Address
    No. 9 Houtan Road, Shangtian Town, Fenghua City, Ningbo City, Zhejiang Province
Contact Now
Three box type hot and cold shock test box, rapid temperature change test box
Ningbo Sida High and Low Temperature Impact Test Box High and Low Temperature Impact Box Cold and Hot Impact Test Box Manufacturer Direct Sales Two bo
Product details

Ningbo Sida High and Low Temperature Impact Test Box High and Low Temperature Impact Box Cold and Hot Impact Test Box Manufacturer Direct Sales

Two box high and low temperature test box Three box high and low temperature impact test box High and low temperature impact box

Introduction to ventilated (three box) temperature shock boxThis test chamber is suitable for assessing the ability of products (whole machines), components, parts, etc. to withstand sudden temperature changes. This temperature shock test can understand the impact of temperature changes on the test sample once or continuously multiple times. The main parameters that affect the temperature change test are the high and low temperature values within the temperature change range, the holding time of the sample at high and low temperatures, and the number of cycles of the test. .

Two box high and low temperature test box, three box high and low temperature impact test box, manufacturer of high and low temperature impact box

Factory direct sales can be customized according to customer requirements

Technical parameters


model

SDCJ-50

SDCJ-100


Performance parameters

Preheating chamber

Upper limit of preheating temperature

200℃

Temperature rise time

R. T. →+200 ℃ for about 40 minutes

Precooling chamber

Lower limit of pre cooling temperature

0~-75℃

Temperature drop time

R. T. → -70 ℃ for about 90 minutes


studio

Temperature shock range

High temperature range of 60 ℃ to+150 ℃; Low temperature -40 ℃~-10 ℃

temperature fluctuation

≤±0.5℃

Temperature deviation

≤±2℃

time of recovery temperature

≤5min


Temperature recovery conditions

SDCJI

Condition 1

High temperature exposure of 125 ℃ and low temperature exposure of -40 ℃, both for 30 minutes.

Condition 2

Exposure to high temperature of 150 ℃ for 30 minutes, ambient temperature for 5 minutes, and low temperature of -40 ℃ for 30 minutes.


SDCI

Condition 1

High temperature exposure at 125 ℃, low temperature exposure at -40 ℃, both for 30 minutes

Condition 2

Exposure to high temperature of 150 ℃ for 30 minutes, ambient temperature for 5 minutes, and low temperature of -405 ℃ for 30 minutes.

Condition Three

High temperature exposure+150 ℃, low temperature exposure -55 ℃, both exposure times are 30 minutes


Structure

casing

Cold rolled steel plate surface spray coating (ivory white)

Liner

Stainless steel plate

Thermal insulation material

Non hazardous waste environmentally friendly glass fiber insulation layer

Refrigeration

Cooling method

water-cooling

refrigeration machine

Imported compressor

test hole

One left side with a diameter of 50mm

controller

Youyi Control or Weishuo

Data storage and functional interface

USBdata interfaceThe device is equipped with a USB storage interface, which stores information including main operating parameters such as test time, test target values, and test measured values

TCP/IPcommunication interface: With 485 interface


Studio size (mm)

D

350

500

W

500

500

H

350

400


External dimensions (mm)

D

1600

1600

W*

1760

1760

H

2200

2200

Installed power (KW)

type i

35KVA

50KVA

type ii

26

30

power supply

AC380V 50Hz three-phase four wire system+grounding wire, protective grounding resistance less than 4 Ω

Standard configuration

1 copy of product manual, 1 copy of test report, 1 copy of certificate of conformity and quality assurance certificate, 5 pieces of printing paper, 2 shelves, 4 shelves, 1 ribbon, 1 set of silicone rubber soft plug, with casters.

Meet standards

GB/T 2423.1、GB/T 2423.2

Safety protection

Phase sequence protection 2, overcurrent protection 3, compressor overvoltage protection 4, leakage protection 5, over temperature protection 6, water shortage protection

No corresponding parameter group found, please add it in the backend property template
Not yet implemented, please stay tuned
Not yet implemented, please stay tuned
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!