Ningbo Sida High and Low Temperature Impact Test Box High and Low Temperature Impact Box Cold and Hot Impact Test Box Manufacturer Direct Sales
Two box high and low temperature test box Three box high and low temperature impact test box High and low temperature impact box
Introduction to ventilated (three box) temperature shock boxThis test chamber is suitable for assessing the ability of products (whole machines), components, parts, etc. to withstand sudden temperature changes. This temperature shock test can understand the impact of temperature changes on the test sample once or continuously multiple times. The main parameters that affect the temperature change test are the high and low temperature values within the temperature change range, the holding time of the sample at high and low temperatures, and the number of cycles of the test. .
Two box high and low temperature test box, three box high and low temperature impact test box, manufacturer of high and low temperature impact box
Factory direct sales can be customized according to customer requirements
Technical parameters
|
model |
SDCJ-50 |
SDCJ-100 |
||||
|
|
Preheating chamber |
Upper limit of preheating temperature |
200℃ |
|||
|
Temperature rise time |
R. T. →+200 ℃ for about 40 minutes |
|||||
|
Precooling chamber |
Lower limit of pre cooling temperature |
0~-75℃ |
||||
|
Temperature drop time |
R. T. → -70 ℃ for about 90 minutes |
|||||
|
|
Temperature shock range |
High temperature range of 60 ℃ to+150 ℃; Low temperature -40 ℃~-10 ℃ |
||||
|
temperature fluctuation |
≤±0.5℃ |
|||||
|
Temperature deviation |
≤±2℃ |
|||||
|
time of recovery temperature |
≤5min |
|||||
|
|
SDCJI |
Condition 1 |
High temperature exposure of 125 ℃ and low temperature exposure of -40 ℃, both for 30 minutes. |
|||
|
Condition 2 |
Exposure to high temperature of 150 ℃ for 30 minutes, ambient temperature for 5 minutes, and low temperature of -40 ℃ for 30 minutes. |
|||||
|
|
Condition 1 |
High temperature exposure at 125 ℃, low temperature exposure at -40 ℃, both for 30 minutes |
||||
|
Condition 2 |
Exposure to high temperature of 150 ℃ for 30 minutes, ambient temperature for 5 minutes, and low temperature of -405 ℃ for 30 minutes. |
|||||
|
Condition Three |
High temperature exposure+150 ℃, low temperature exposure -55 ℃, both exposure times are 30 minutes |
|||||
|
|
casing |
Cold rolled steel plate surface spray coating (ivory white) |
||||
|
Liner |
Stainless steel plate |
|||||
|
Thermal insulation material |
Non hazardous waste environmentally friendly glass fiber insulation layer |
|||||
|
Refrigeration |
Cooling method |
water-cooling |
||||
|
refrigeration machine |
Imported compressor |
|||||
|
test hole |
One left side with a diameter of 50mm |
|||||
|
controller |
Youyi Control or Weishuo |
|||||
|
Data storage and functional interface |
USBdata interfaceThe device is equipped with a USB storage interface, which stores information including main operating parameters such as test time, test target values, and test measured values TCP/IPcommunication interface: With 485 interface |
|||||
|
|
D |
350 |
500 |
|||
|
W |
500 |
500 |
||||
|
H |
350 |
400 |
||||
|
|
D |
1600 |
1600 |
|||
|
W* |
1760 |
1760 |
||||
|
H |
2200 |
2200 |
||||
|
Installed power (KW) |
type i |
35KVA |
50KVA |
|||
|
type ii |
26 |
30 |
||||
|
power supply |
AC380V 50Hz three-phase four wire system+grounding wire, protective grounding resistance less than 4 Ω |
|||||
|
Standard configuration |
1 copy of product manual, 1 copy of test report, 1 copy of certificate of conformity and quality assurance certificate, 5 pieces of printing paper, 2 shelves, 4 shelves, 1 ribbon, 1 set of silicone rubber soft plug, with casters. |
|||||
|
Meet standards |
GB/T 2423.1、GB/T 2423.2 |
|||||
|
Safety protection |
Phase sequence protection 2, overcurrent protection 3, compressor overvoltage protection 4, leakage protection 5, over temperature protection 6, water shortage protection |
|||||