VIP member
Three box thermal shock test chamber
Product use: The three box cold and hot shock test chamber is an essential testing equipment in the metal, plastic, rubber, electronics and other mate
Product details
| Device Model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
| LRHS-100A-LW | 450×500×450 | 1700×1440×1900 | |
| LRHS-150A-LW | 500×600×500 | 1750×1540×2115 | |
| LRHS-225A-LW | 750×600×500 | 2200×1540×2115 | |
| LRHS-320A-LW | 800×800×500 | 2400×1740×2050 | |
| LRHS-500A-LW | 1000×900×550 | 2600×1840×2080 | |
Technical Specifications
Sales Hotline: 021-608 99999
| sex can point mark |
Impact temperature range | A:-45℃~150℃ B:-55℃~150℃ C:-65℃~150℃ | |||
| High temperature box temperature | RT~180 ℃ (unloaded) | ||||
| Low temperature box temperature | RT~-60 ℃ (unloaded) | ||||
| temperature fluctuation | ≤ 1 ℃ (when unloaded) | ||||
| temperature deviation | ± 3 ℃ (when unloaded) | ||||
| heating rate | From room temperature to 150 ℃ ≤ 25 minutes (average throughout the entire process) | ||||
| 降温速率 | From room temperature to -60 ℃ ≤ 50min (average throughout the entire process) | ||||
| Temperature recovery time | ≤5min | ||||
|---|---|---|---|---|---|
| Time setting range | 1~60000M | ||||
| test hole | Used for external testing of power or signal lines | ||||
| make use material material |
outer box material | High quality A3 steel plate electrostatic spraying | |||
| Inner box material | Imported high-grade stainless steel SUS304 | ||||
| Insulation material | Rigid polyurethane foam+glass fiber | ||||
| nucleus heart match place |
Temperature Controller | Imported "Youyi Control" brand temperature instrument | |||
| temperature sensor | PT100 platinum resistance thermometer | ||||
| Cooling method | Double machine cascade refrigeration | ||||
| compressor | French Taikang Compressor/German Bitzer Compressor | ||||
| Standard Configuration | Sample rack with 2 layers, equipped with condensate water collection tray, and discharged outside the box | ||||
| safety protection | Compressor overpressure overload, overtemperature, leakage protection, fan motor overheating Overall equipment under phase/reverse phase overall equipment timing, overload, and short circuit protection |
||||
| power supply voltage | AC380V±10% 50Hz | ||||
| Power | (A) 17.0kW/22.0kW/25.0kW 53.0kW/72.0kW | ||||
| Usage environment | 5℃~+28℃ ≤85% RH | ||||
| Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. Customized cold and hot shock test chambers can be customized according to specific testing requirements of users 3. This technical information is subject to change without prior notice |
|||||
Online inquiry