Jiangsu Oubai Automation Instrument Co., Ltd
Home>Products>Thermal resistance isolated safety barrier
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13813330667,15250863077
  • Address
    No. 68 Jianshe Road, Minqiao Industrial Concentration Zone, Jinhu County, Jiangsu Province
Contact Now
Thermal resistance isolated safety barrier
Thermal resistance input type safety barrier is a control system or other unit combination instrument that isolates and converts the thermal resistanc
Product details
  • Thermal resistance input type safety barrier is a control system or other unit combination instrument that isolates and converts the thermal resistance signal in the hazardous area on site into a linear DC signal with temperature, and outputs it to the safety zone.
    Intelligent thermal resistance temperature transmitter that can configure and set the type and range of thermal resistance.
    This safety barrier requires independent power supply, with three terminals isolated from input, output, and power supply.
    Equipped with a working power indicator light.
    Plug and unplug terminal block, DIN rail card installation.

    Channel configuration:One in one out, one in two out, two in two out
    Input signal:
    Pt100, Pt50, Cu100, Cu50, etc
    Output signal:4-20mA;0-10mA; 0-20mA;(or specify current range)
    Output voltage:1-5V; 0-5V; 0-10V;(or specify voltage range)

    CQST authentication parameters:
    Explosion proof grade mark:【Exia Ga】IIC;
    Security authentication parameters:
    9. Between terminals 10 and 11, between terminals 13, 14, and 15 (second channel)
    Um=250V AC/DC ,Uo=5.6VDC , Io=112mA
    Po=160mW , Co=38uF , Lo=1mH

    Power consumption:Single channel 0.8W, dual channel 1.5W

Working power supply Power wiring: independent wiring terminals 3+, 4-, can be plugged and unplugged with power on
Power supply voltage: 18V DC~32V DC
Power indicator: Power on LED light on: green
input circuit
(Exia IIC Hazardous Area)
Input channel:Terminals 9, 10, 11, 13, 14, and 15 are connected to thermal resistors
Input thermistor signals: Pt100, Pt50, Cu100, Cu50, etc
Lead resistance: ≤ 200 Ω/wire
output circuit
(Safe Zone)
Output channel:Terminals 5 and 6; 7. 8 Wiring (see terminal wiring diagram for details)
Output signal:4-20mA;0-10mA; 0-20mA; (or specified current range)
Load capacity: ≤ 300 Ω (if larger load capacity is required, please customize)
Output voltage: 1-5V; 0-5V; 0-10V; (or specified voltage range)
Load capacity:0(1)~5V:≥1MΩ;0-10V:≥2MΩ
sexually


ability


finger


treetop
Isolation accuracy: ± 0.2% F • S (25 ℃± 2 ℃ excluding cold end compensation)
Temperature drift:<30ppm/℃
Response time:≤0.5ms
Impact of power supply voltage variation: ± 0.1% (allowable voltage range)
Insulation resistance: ≥ 100M Ω (between input/output/power supply)
Dielectric strength: ≥ 2500V AC (leakage 1mA between input/output/power supply)
Isolation capability: 1500VAC/1 minute 50Hz
Channel isolation: isolation between input output power supply
Electromagnetic compatibility: EMC complies with IEC61000-4

    environmental condition Working temperature: -20 ℃~+60 ℃
    Allowable relative humidity at work: 10% RH~90% RH (40
    Allowable atmospheric pressure during work: 80Kpa~110Kpa
    Product specifications Structure: rail type; ABS material casing; Plug in terminals;
    Dimensions: W13.5 * D100 * 115 (mm)
    W22.5*D100*115(mm)
    Whole machine weight: 170g~190g
      Online inquiry
      • Contacts
      • Company
      • Telephone
      • Email
      • WeChat
      • Verification Code
      • Message Content

      Successful operation!

      Successful operation!

      Successful operation!