Technical parameters of thermal abuse (thermal shock) test chamber
1、 Hot abuseThe experiment shall be conducted according to the following steps:
Connect the battery according to4.5.1After being fully charged according to the prescribed test method, place the battery into the test chamber. Test box(5±2)℃/minThe temperature rise rate is increased when the temperature inside the box reaches130℃±2Maintain a constant temperature after ℃ and continue to do so30min.
The battery should not catch fire or explode.
2、 Main technical parameters
|
rule grid |
model |
CZ-RL-01 |
|
internal volume |
175L |
|
|
studio dimensions |
Approximately W50 × H70 × D50cm |
|
|
Overall dimensions |
Approximately W88 × H168 × D73cm |
|
|
box body knot constitute |
structure |
monolithic |
|
outer box material |
High quality thickened cold-rolled steel plate (gray+blue) baked paint |
|
|
Inner box material |
High quality thickened stainless steel |
|
|
observation window |
Tempered glass observation window (350×400mm double-layer explosion-proof glass) |
|
|
LED lighting |
||
|
Exhaust device |
Configure forced exhaust device |
|
|
pressure relief device |
Configure automatic pressure relief port |
|
|
main want skill technique point mark |
Control method |
PLC touch screen |
|
temperature range |
RT+10℃~+150℃(Customizable) |
|
|
heating rate |
RT→+150 ℃ ≤ 5 ℃/min (average throughout the entire process) |
|
|
resolution |
0.1℃ |
|
|
volatility |
±0.5℃ |
|
|
bias |
≤2.0℃ |
|
|
uniformity |
≤2.0℃ |
|
|
Standard Configuration |
Host and sample rack 2Insulation epoxy resin sample partition |
|
|
power supply voltage |
AC220V 50Hz、AC380V 50HZ |
|