Machine model: ZB-303Theoretical large relative density meter for asphalt mixture
One Scope of Application
The theoretical high relative density meter for asphalt mixture is suitable for measuring the theoretical high relative density of asphalt mixture by vacuum method, which is used for asphalt mixture mix design, road condition investigation or pavement construction quality management calculation of void ratio, compaction degree, etc.
II Main technical parameters
1. Vibration gap: 3 minutes
2. Vacuum degree: 3.7MPa
3. Container capacity: 5000ml × 2
4. Oscillation mode: continuous/intermittent
5. Power: 300W
6. Power supply voltage: 220V ± 10%, 50Hz;
7. Dimensions: 500 × 520 × 380 (mm).