Product Name: Tea Safety Rapid AnalyzerProduct Model:GNSSP-CY04

Product brand: Zhong'anAolksafe product code:

Exterior dimensions: 310mm × 310mm × 140mm Net weight: 2.95kg



number

Testing items

detection range

mg/kg

detection limit

mg/kg

Specific pesticide name

1

pyrethroid

0.5——10

0.5

Cypermethrin, bromocyhalothrin, fluorocyhalothrin, cypermethrin, etc

2

Dicofol

1.0——40

1.0

Dicofol

3

Organophosphorus

0.5——10

0.5

Methamidophos, acetamiprid, dimethoate, dichlorvos, chlorpyrifos, methomyl, etc

4

organochlorine

0.5——20

0.5

666, DDTDDTclass

The principle of Lambert Beer's law

quantitative analysis


The rapid analysis of tea safety is based on the characteristic absorption spectrum and light absorption law of visible light produced by substance molecules (Lambert)The principle of Bill's Law is an instrument used for quantitative analysis by comparing an unknown concentration sample with a known concentration standard substance.


LCD display screen+Silicon Rubber Keypads

Direct reading, long button lifespan, high protection level





Equipped with online software for online operation

Humanized interface, convenient human-machine dialogue


equipUSB/RS232/Vehicle power interface

Strong scalability, convenient for equipping mobile detection vehicles


Embedded micro printer

Direct and fast printing with clear handwriting

1.Pyrethroid (purple or purple red) (detection range)0.5-10mg/kg

project name

Sample processing

Detection steps

pyrethroid

Cut and weigh2.0gIn a beaker;

add10mLExtraction solution;

Mix well and extract with ultrasound10min

That is, the sample processing solution.

contrast:

Test tube addition2.5mLtreatment liquid+1Drop No.1, let it stand still5min

add1mLNumber II, shaking up and down30Below;

0.3 mLNo. IIIMix well,50℃ water bath10min

add1mLWater, mix well, let it stand2-5minLayering;

Take the lower layer liquid into a colorimetric dish, place it in the instrument, and pressConduct a blank test.

Sample:

Test tube addition2.5mLtreatment liquid+1Drop No.1, let it stand still5min

add1mLNumber II, shaking up and down30Below;

add0.3 mLIII+1 drop IVMix well,50℃ water bath10min

add1mLWater, mix well, let it stand2-5min, Layered

Take the lower layer liquid into a colorimetric dish, place it in the instrument, and press<M>Key for sample testing.


In the detection stepsItems I, II, etc. refer to detection liquid I, detection liquid II, etc. The following items are all included;

Blank control and sample should be done simultaneously, and the following items should also be done simultaneously with blank control and sample.



2. Trichlorofenapyr (red) (detection range)1-40mg/kg

project name

Sample processing

Detection steps

Dicofol

Cut and weigh1.0gIn a beaker;

add1mLExtract Liquid I and6mLExtract liquid II;

stir30SPost ultrasonic extraction15min,

Suck the extraction solution into a test tube165-70Concentrate to about ℃ in a water bath3 mL

test tube1add1mLExtract liquid III, mix well;

3000r/minCentrifuge for 3 minutes; Take the upper clear liquid and transfer it to a test tube2

test tube2a surname85-95Evaporate in a water bath at ℃.

contrast:

Dry and empty test tube addition1mLExtract Liquid I and6mLExtract liquid II;Mix well, then80-90In a water bath at ℃, evaporate;

add4Di Ⅰ and2Drip II, oscillation30Next, ultrasound extraction3min

add2mLNumber III, oscillation30Below,100Boil water at ℃ for 3 minutes;

Cool down, take the upper liquid into a colorimetric dish, place it in the instrument, and pressPerform a blank test on the key.

Sample:

Dried test tube2add4Di Ⅰ and2Drip II, oscillation30Next, ultrasound extraction3min

add2mLNumber III, oscillation30Below,100Boiling water bath at ℃ for 3 minutes

Cool down, take the upper liquid into a colorimetric dish, place it in the instrument, and pressKey for sample testing.

Centrifuge has1234The file,1files1000Turn, turn to3exactly3000r/min

Six centrifuge tubes can be placed inside the centrifuge at the same time. During centrifugation, the centrifuge tubes should be symmetrically placed so that the centrifuge will be flat and not deviate from the edge when rotating;

Need to use3A test tube, blank control1A test tube, sample2A test tube, a test tube1And test tube2.



3. Organic phosphorus (yellow) (detection range)0.5-10mg/kg

project name

Sample processing

Detection steps

Organophosphorus

Cut and weigh1.0gIn a beaker;

add6mLExtract liquid, mix well;

ultrasound extraction10min

add0.1-0.5gActivated carbon decolorization;

Filter with double-layer filter paper in a test tube;

60~70Evaporate in a water bath at ℃,To be tested.

contrast:

Dry and empty test tube addition1mLWater and1mLNumber one, oscillation1min

add1mLNumber II, oscillation20Below,60℃ water bath10min

Remove and cool to room temperature(20-30℃), draw the liquid into a colorimetric dish;

Insert the instrument and press<B>Perform a blank test on the key.

Sample:

Dried test tube added1mLWater and1mLNumber one, oscillation1min

add1mLNumber II, oscillation20Below,60℃ water bath10min

Remove and cool to room temperature(20-30℃), draw the liquid into a colorimetric dish;

Insert the instrument and press<M>Key for sample testing.



4. Organic chlorine (red) (detection range)0.5-20mg/kg

project name

Sample processing

Detection steps

organochlorine

Cut and weigh1.0gIn a beaker;

add5mLExtract liquid I, mix well;

ultrasound extraction10min

Add a small amount(0.2-0.5g)Powder reagent, mix well;

Suck the extract into a test tube;

add2mLExtract solution II, shake well, let it stand and separate into layers,Suck and discard the lower layerLiquid;

Plus2mLExtract solution II, shake well, let it stand and separate into layers,Suck and discard the lower layerLiquid (to be sucked clean);

add0.2mLExtract liquid III, shake20Next, ultrasound extraction3-5min

add2.5mLExtract liquid II, mix well, let it stand and separate into layers,Suck and discard the upper layerLiquid;

add2mLExtract liquid I, mix well, let it stand and separate into layers,Suck and discard the upper layerLiquid;

The rest is the sample tube.

contrast:

Dry and empty test tube addition2.5mLExtract liquid II;

add2.5mLNo. 1, shake well;

add1.0mLNo. II, shake well;

add1.0mLNo. III, shake well and let it stand20min

Pour into the colorimetric dish, put in the instrument, and press<B>Perform a blank test on the key.

Sample:

Sample tube addition2.5mLNo. 1, shake well;

add1.0mLNo. II, shake well;

add1.0mLNo. III, shake well and let it stand20min

Pour into the colorimetric dish, put in the instrument, and press<M>Key for sample testing.

²Transmittance accuracy

≤±1.5%

²Transmission density repeatability

≤0.5%

²Number of measurement channels

1individual

²linearity error

≤±5%

²Photocurrent stability

≤±1%/3min

²insulation resistance

20MΩ

²LCD display screen

4.5 inches

²key

Silicone button, with a lifespan of up to 500000 times, dustproof and waterproof

²ambient temperature

5-35℃

²relative humidity

≤85%

²RS232/USBinterface

1 each

²Car power cord interface

1 piece

²Instrument dimensions

310mm×310mm×140mm

²net weight

2.95kg

²The power adapter

AC220V,50HZ

²Car power supply

12V (optional)


number

Testing items

detection range

mg/kg

detection limit

mg/kg

Specific pesticide name

1

pyrethroid

0.5——10

0.5

Cypermethrin, bromocyhalothrin, fluorocyhalothrin, cypermethrin, etc

2

Dicofol

1.0——40

1.0

Dicofol

3

Organophosphorus

0.5——10

0.5

Methamidophos, acetamiprid, dimethoate, dichlorvos, chlorpyrifos, methomyl, etc

4

organochlorine

0.5——20

0.5

666, DDTDDTclass


Serial Number

name

model

unit

quantity

1

host machine

GNSSP-CY04

tower

1

2

power supplyadapter

12V/2.5A

strip

1

3

data line

USB

strip

1

4

Software CD

Online software

fix

1

5

instructions

——

share

1

6

warranty card/certificate of conformity

——

fix

1

7

hostbox

——

individual

1

Note: One set of experimental equipment is included as a gift. Different models of experimental equipment may vary when purchased. Please contact customer service for more information on the related complimentary equipment.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!