ageTIME2500 Coating Thickness Gauge (Magnetic Method) - Original TT220
TIME2500 Coating Thickness Gauge (Magnetic Method)Meet the following relevant standards:
GB/T 4956-2003 Non magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method
TIME2500 Coating Thickness Gauge (Magnetic Method)Functional features:
♦ Zero point calibration and two-point calibration can be performed, and basic calibration methods can be used to correct the systematic errors of the measuring head;
♦ There are five statistical measures: Mean (MEAN), Maximum (MAX), Minimum (MIN), Number of Tests (NO.), and Standard Deviation (S.DEV);
♦ Has deletion function: delete current value, calibration value, limit value, and all values;
♦ There are two measurement methods: continuous measurement and single measurement;
♦ Store 500 measurement values;
♦ There are two working modes: direct mode and batch mode;
♦ Chinese and English menus;
♦ Equipped with undervoltage indication function;
♦ There is a buzzing sound during the operation process;
♦ Equipped with error prompt function;
♦ Backlight display; ♦ Automatic and manual shutdown.
TIME2500 Coating Thickness Gauge (Magnetic Method)Technical parameters:
|
Probe type |
F |
|
|
measuring principle |
magnetic induction |
|
|
measuring range |
0-1250µm |
|
|
Low limit display resolution |
0.1 µ m (0.1 µ m below 100 µ m) |
|
|
Probe connection method |
integration |
|
|
Indication error |
Zero point calibration (um) |
±[3% H + 1] |
|
Two point calibration (um) |
±[(1% ~ 3%) H + 1] |
|
|
Measurement conditions |
*Small curvature radius (mm) |
Convex 1.5; Concave 9 |
|
Diameter of substrate * small area (mm) |
ф7 |
|
|
*Small critical thickness (mm) |
0.5 |
|
|
Temperature and humidity |
0~40℃ ; 20%RH~90%RH |
|
|
STATISTICS |
Mean value (MEAN), maximum value (MAX), minimum value (MIN) |
|
|
way of working |
Direct method and group method (Appl) |
|
|
Measurement method |
Continuous measurement method and Single measurement method |
|
|
Storage capacity |
Store 500 measurement values |
|
|
Print/Connect Computer |
Optional printer/unable to connect to computer |
|
|
Shutdown mode |
There are two modes: automatic and manual |
|
|
power supply |
AAA type 1.5V (No. 7) dry battery 2 pieces |
|
|
External dimensions |
146×60×28mm |
|
|
weight |
132g |
|
TIME2500 Coating Thickness Gauge (Magnetic Method)Basic configuration:
TIME2500 host 1 unit
1 set of standard samples
1 standard substrate
1 instrument box
If necessary, please leave your detailed contact information!