Shanghai Wujiu Automation Equipment Co., Ltd
Home>Products>TG328B Optical Analysis Balance
TG328B Optical Analysis Balance
TG328B Optical Analysis Balance Weighing Range: 0-200g Dividing Value: 0.1mg Optical Reading Range: 0-10mg Mechanical Weight Range: 10-990g Weighing P
Product details

TG328B Optical Analysis Balance

scope of application

Can be used for precision measurement and analysis in laboratories and laboratories of industrial and mining enterprises, scientific research institutions, and universities.

Product Introduction

TG328B Optical Analysis Balance

Analytical balance is a commonly used analytical instrument in laboratories and other places in recent years. It has a wide range of applications, with advantages such as high accuracy, good stability, and advanced functions. Analytical scales are relatively precise, so patience and meticulousness are required during use and maintenance. A slight mistake can easily cause minor malfunctions, affecting weighing results and service life. Below, we will introduce the operating procedures and precautions for analytical scales, hoping to be helpful to everyone.
Operating procedures for analytical scales:
1. Check if the balance is level, observe the level, if the water bubble on the level is offset, adjust the level adjustment foot to make the level at the center of the level.
2. Open the side doors on both sides for 5-10 minutes to balance the humidity and temperature inside and outside the balance, avoiding changes in the displayed values caused by differences in humidity and temperature inside and outside the balance cover. Close the side doors properly.
3. Check if the balance pan is clean. If there is dust, use a brush to clean it.
4. Turn on the power, preheat for one hour, and then turn on the monitor.
5. Select the weighing mode and perform weighing.
6. Press the TAR key to display the zero layer, place the object on the disk, and wait for the number to stabilize (after the "0" symbol on the left side of the display goes out). This number is the mass value of the object being weighed.
7. After weighing, take out the object to be weighed, close the balance door, turn off the monitor, cover with a dust cover, and register.
Precautions for using analytical balance:
1. The balance should be used with care. The weighing plate and shell should be gently wiped with a soft cloth and toothpaste, and strong solvents should not be used for wiping.
2. Do not weigh items that are too cold or too hot on a balance. Instead, wait for the temperature of the object and the balance chamber to increase before weighing.
3. Silicone desiccant should be placed inside the balance frame, and it should be dried promptly after the blue color of the desiccant disappears.
4. If the balance is not used for a long time, the power cord should be disconnected.
5. After weighing, promptly remove the weighed item and keep the balance clean.
6. The load capacity of the balance should not exceed the maximum load, and the weighed object should be weighed in a dry and clean container.

model

TG128

TG335

TG332A

Weighing Range

0~200g

0~2g

0~20g

Resolution

0.02mg

0.001mg

0.01mg

optical reading range

0.02-1mg

0.001-0.1mg

0.01-1mg

Mechanical code reduction range

1-99mg

Weighing disk size

Φ74mm

Φ25mm

Φ37mm

External dimensions

430×310×590(mm)

310×265×395(mm)

270×310×417(mm)

net weight

20kg

16.5kg

14.5kg

model

TG328A/S

TG328B

TG528B

TG628A

TG928C

Weighing Range

0~200g

0~200g

0~200g

0~200g

0~200g

Resolution

0.1mg

0.1mg

0.5mg

1mg

10mg

optics

Reading range

0-10mg

machinery

Reduce code range

0.01-199.99g

10-990Mg

Weighing disk size

Φ75mm

External dimensions

(mm)

420×370×500

390×325×485

390×285×485

370×230×390

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!