Functional Features
Power measurement capability: voltage up to 10 kV, current up to 1000 A, manual/automatic range shifting.
Harmonic measurement function: It can analyze and display the content of 2nd to 64th harmonics, total harmonic distortion in real time, and draw harmonic spectrograms (spectrograms).
Other testing functions: oscilloscope, phasor graph display, power stability testing, trend change curve, statistical analysis, etc.
◉ Energy metering function: It has power and energy measurement functions for fundamental wave, 2-64th harmonic, and DC components.
◉ Good human-machine function: Equipped with a large LCD color screen, the measurement value display is intuitive, and it adopts a full touch operation method, making it extremely convenient to use.
Three phase voltage measurement
Three phase current measurement
Frequency/Phase/Harmonic
Frequency adjustment range: 45.0000 Hz to 1000.00 Hz, minimum resolution: 0.0001 Hz, optimal measurement uncertainty: 0.01 Hz
Phase adjustment range: 0.0000 °~359.9999 °, minimum resolution: 0.0001 °, optimal measurement uncertainty: 0.05°@50 Hz
Proportional measurement of DC sensor
Power/electric energy measurement range: combination of voltage range and current range
Power/energy measurement uncertainty: voltage measurement uncertainty+current measurement uncertainty
High frequency power pulse output: 60 kHz corresponding to full-scale value
Low frequency power pulse output: Full scale value corresponds to 6 Hz
Electric energy pulse transmission: ≤ 10 kHz, input voltage level: 3.3 V ... 24 V