Bacterial filtration efficiency detector
Product images

Product Introduction
The Bacterial Filtration Efficiency (BFE) Tester (product model SUP_XJXT) is a high-performance intelligent bacterial filtration efficiency tester developed in strict accordance with the experimental method requirements for BFE in Appendix B of YY/T0969-2013 and YY0469-2011 "Medical Surgical Masks". It also meets the requirements of ASTM F2100, ASTM F2101, and EN14683. The design system based on negative pressure biosafety cabinet working environment is adopted, which is safe and convenient to use, and the quality is controllable. The method of simultaneous comparison sampling with dual gas paths has accurate sampling and high detection efficiency. Adopting a touchable color industrial resistive screen, it can be easily operated in various situations. Applicable to performance testing of mask bacterial filtration efficiency by inspection and quarantine units, metrological verification departments, research institutes, mask production, and related departments.
Product features:
Professional negative pressure biosafety cabinet technology ensures the safety of operators and the environment;
High negative pressure working chamber, two-stage high-efficiency filters, 100% safe discharge;
Adopting two-way six level Anderson precise sampling;
Built in peristaltic pump, with adjustable flow rate;
Special microbial aerosol generator, the flow of bacterial liquid spray can be adjusted, and the atomization effect is good;
Industrial grade ultra large color touch screen control, easier to operate;
USB interface, supporting data transfer and storage;
RS232/Modbus standard interface (or custom protocol), capable of external control.
The safety cabinet is equipped with LED lighting for easy observation;
Built in UV disinfection lamp to enhance protection effect;
Front switch sealed glass door, convenient for operation and observation;
Comes with SUP-BF-AS operating software, which can be controlled and processed through a computer,
Seamless integration with laboratory information management system.
Parameters |
Parameter range |
resolution |
accuracy |
sample flow |
28.3 L/min |
0.1 L/min |
±2% |
Spray flow |
8 ~ 10 L/min |
0.1 L/min |
±5% |
Peristaltic pump flow rate |
0.006~3 mL/min |
0.001 mL/min |
±2% |
Pressure before sampling flowmeter |
-20 ~ 0 kPa |
0.01 kPa |
±2% |
Front pressure of spray flowmeter |
0 ~ 300 kPa |
0.1kPa |
±2% |
Negative pressure in the aerosol chamber |
-90 ~ -120 Pa |
0.1Pa |
±1% |
operation temperature |
0~50 ℃ |
||
Cabinet negative pressure |
> 120Pa |
||
Data storage capacity |
>500000 sets, expandable capacity |
||
Performance of high-efficiency air filter |
≥99.995%@0.3μm,≥99.9995%@0.12μm |
||
|
Dual channel six stage Anderson sampler Capture particle size |
Grade I>7 μ m, Grade II 4.7~7 μ m, Grade III 3.3~4.7 μ m, Grade IV 2.1~3.3 μ m, Grade V 1.1~2.1 μ m, Grade VI 0.6~1.1 μ m |
||
Total number of particles in the positive quality control sampler |
2200±500 cfu |
||
Mass median diameter of aerosol generator |
Average particle diameter (3.0 ± 0.3 µ m), geometric standard deviation ≤ 1.5 |
||
Specification of aerosol chamber |
Length 600 x Diameter 85 x Thickness 3mm |
||
Ventilation flow rate of negative pressure cabinet |
>5m3/min |
||
Host size |
Inner: 1000 * 600 * 690mm, Outer: 1470 * 790 * 2100mm |
||
work noise |
< 65db |
||
Working power supply |
AC220±10%,50Hz,1500W |
||
Whole machine weight |
About 300Kg |
||