Main technical features:
1. The instrument design meets the technical requirements and detection methods of water quality automatic samplers(HJ/T372-2007)
5. Traffic characteristics:300~1600mL/min ★
6. Horizontal suction range:100Rice, with automatic drainage and pre rinsing functions for pipelines ★
9. It has multiple sampling methods such as proportional sampling, excess retention sampling, manual control sampling, timed quantitative sampling, real-time quantitative sampling, liquid level proportional sampling, and fixed flow quantitative sampling;
Brief introduction
TC-8000E-IIThe Type Proportional Automatic Water Collector Instrument is a fully automatic water collector designed based on the current situation of water pollution in China and the needs of environmental testing departments; The instrument meets the technical requirements and testing methods of automatic water quality samplers(HJ/T372-2007)It is a multifunctional monitoring instrument that integrates flow measurement and water sample collection. This model of water sampler introduces a highly stable peristaltic pump, combined with an intelligent program, which can achieve multiple sampling modes such as timed, quantitative, timed interval, and fixed flow interval. It is suitable for GE level environmental monitoring stations, sewage treatment plants, water conservancy, water affairs, and research institutes to automatically sample water samples from industrial pollution source discharge outlets, rivers, lakes, seas, and other sources.
2、 Product Features
1.Multiple sampling program startup methods: preset time startup, external signal triggered startup, over limit sample retention startup, instant startup, liquid level over limit triggered startup, etc., to meet the needs of users' GE Zhong applications.
2.Multiple sampling functions: timed quantitative sampling, fixed flow quantitative sampling, flow ratio sampling, liquid level ratio sampling, real-time quantitative sampling.
3.Multiple external signal access methods, including4~20mASignal2roadRS232SignalRS485Signal and switch signal interface, convenient for online operation with online devices.
4.There is an automatic emptying function for the pipeline, which automatically empties the pipeline after the sample collection is completed, meeting the GE water quality conditions. It also has a pre rinsing function for the pipeline to ensure the collection of representative samples.
5.Automatic sample packaging, with a variety of sample packaging methods.
6.Equipped with a remote communication interface, it can remotely control the startup through SMS and remotely check the on-site status (optional).
7.Rich operation record saving function, where every key operation of the user is recorded, facilitating future queries.
8.Rich data query function, large capacity data storage, can store10000Sampling records2000Alarm records can be queried for hourly, daily, and monthly traffic data for two years, facilitating user statistical analysis.
9.It has printing and communication functions, and can output on-site data to a computer or printer.
10.Two level password lock and two level management permissions to prevent illegal operations.
11.Liquid sensors detect liquids and improve sample collection accuracy.
12.Humanized program design, simple and efficient system operation, allowing direct observation of the sample volume of each sample bottle from the screen.
13.Using highly reliable peristaltic pumps and imported peristaltic tubes, with long service life, low noise, and low maintenance costs.
14.Built in large capacity lithium battery, dual-use for AC and DC, battery power can support continuous operation48Hours, equipped with a car charging interface.
15.The whole machine is small in size and light in weight, equipped with positioning universal wheels, making it easy to move.
16.The waterproof design of the whole machine ensures that it can work in rainy and harsh weather conditions, making it convenient for outdoor applications.
III Technical Parameter
Sampling method |
Peristaltic pump suction type |
Sampling rate |
5ml~1200ml/min |
Vertical suction |
8rice |
Sample bottle capacity |
1000ml |
Sampling quantity error |
±5% |
Proportional sampling error |
±10% |
Number of samples |
1—24It can be set up and mixed samples can also be collected |
Bottle splitting method (not limited to) |
Single bottle, single sample |
Single bottle variety |
|
Multiple bottles per sample |
|
Sampling method(not limited) |
Timed and quantitative sampling |
Fixed flow quantitative sampling |
|
Waiting time and traffic ratio |
|
Waiting time and liquid level ratio |
|
Manual control sampling |
|
sampling interval |
1Minutes to9999Minute adjustable |
Single sampling quantity |
1Milliliters to9999Adjustable milliliters |
liquid crystal display |
Pure ChineseLCDBlue backlight |
key |
3×5Thin film micro motion button |
Internal Clock |
Real time clock, monthly cumulative error less than10second |
External dimensions |
460*370*480(Company:mm) |
Sampling program |
|
start mode |
Instant start, timed start, external signal start, etc |
Communication method |
4~20mA\\RS232(2Road)\\RS485\\Switching quantity\\pulse |
Sampling program preset |
Users can pre-set in advance10Sampling program |
Power on self-test |
Data storage, clockRAM、ROM |
Data Storage |
|
discharge record |
2Annual hourly data, daily data, monthly data, annual data |
sampling record |
10000strip |
Alarm and information recording |
2000strip |
power supply/power |
|
power supply |
AC:220V±15%,DC+12V,10AH |
built-in battery |
Large capacity imported lithium batteries,DC+12V,10AH |
overload protection |
5AHot melt fuse |