The TBW series is a variant of the TB series with water cooling. Its feature is a fully integrated and highly effective cooling system that enables this series of motors to achieve higher continuous thrust than standard versions, while maintaining sub micron positioning accuracy and withstanding extreme acceleration. Because heat does not dissipate into mechanical structures, it is particularly suitable for applications with heat dissipation issues.
Specifications
| parameter | symbol | unit | TBW18 | TBW30 | TBW45 | |||||||||||||||
| winding type | N | S | N | S | N | S | ||||||||||||||
| Motor type, maximum phase to phase voltage | 3-phase synchronous with iron core, 400Vac rms (600Vdc) | |||||||||||||||||||
| Ultimate thrust (at a temperature rise of 10 ℃/s) | Fu | N | 2700 | 4500 | 6750 | |||||||||||||||
| Peak thrust (at a temperature rise of 6 ℃/s) | Fp | N | 2400 | 4000 | 6000 | |||||||||||||||
| Continuous thrust during water cooling* | Fcw | N | 1200 | 2000 | 3000 | |||||||||||||||
| Continuous thrust during air cooling* | Fc | N | 1140 | 1900 | 2850 | |||||||||||||||
| Maximum speed** | vmax | m/s | 3 | 6 | 2.5 | 6 | 2.5 | 6 | ||||||||||||
| Motor thrust constant | K | N/Arms | 186 | 90 | 225 | 93 | 225 | 93 | ||||||||||||
| motor constant | S | N2/W | 2580 | 4300 | 6450 | |||||||||||||||
| limiting current | Iu | Arms | 19.6 | 41 | 27 | 65 | 41 | 98 | ||||||||||||
| peak current | Ip | Arms | 15 | 31.1 | 20.7 | 50 | 31 | 75 | ||||||||||||
| Continuous current during water cooling* | Icw | Arms | 6.5 | 13.4 | 8.9 | 21.5 | 13.4 | 32.3 | ||||||||||||
| Phase peak reverse electromotive force | Bemf | V/m/s | 152 | 76 | 183 | 76 | 183 | 76 | ||||||||||||
| Resistance/Phase* | Rph | Ω | 4.4 | 1 | 3.9 | 0.66 | 2.6 | 0.44 | ||||||||||||
| Inductance/Phase | Lph | mH | 35 | 8 | 31 | 5 | 21 | 3 | ||||||||||||
| Electrical time constant* | τe | ms | 8 | 8 | 8 | |||||||||||||||
| Maximum continuous power consumption | Pc | W | 726 | 1209 | 1804 | |||||||||||||||
| thermal resistance | Rth | °C/W | 0.1 | 0.06 | 0.04 | |||||||||||||||
| Thermal time constant* | τth | s | 87 | 87 | 87 | |||||||||||||||
| Water cooling flow rate | Φw | l/min | 3.1 | 5.2 | 7.8 | |||||||||||||||
| Water cooling pressure drop | ∆Pw | bar | 1 | 1.5 | 2.5 | |||||||||||||||
| temperature sensor | PTC 1kΩ / KTY 83-122 | |||||||||||||||||||
| Weight of the moving object | W | kg | 7.3 | 12.3 | 18.2 | |||||||||||||||
| Length of mover | L | mm | 344 | 580 | 852 | |||||||||||||||
| Motor attraction | Fa | N | 4900 | 8300 | 12450 | |||||||||||||||
| Magnetic pole distance NN | τ | mm | 24 | 24 | 24 | |||||||||||||||
| Cable quality | m | kg/m | 0.3 | 0.3 | 0.3 | |||||||||||||||
| Type of power cable | d | mm (AWG) | 11.9 (14) | 16.9 (10) | ||||||||||||||||
| Temperature sensor cable type | d | mm (AWG) | 4.3 (26) | |||||||||||||||||
|
*These values are only applicable when the installation surface is at 20 ° C and the motor is driven at maximum continuous current. If these values are different in your application, please check our selection software. **The actual value depends on the bus voltage. Please check the F/V chart in the selection software.
|
||||||||||||||||||||