Shenzhen York Technology Co., Ltd
Home>Products>Six function verification furnace E-6
Six function verification furnace E-6
Product Name: Six Function Calibration Furnace E-6 Product Model: Six Function Calibration Furnace E-6 Product Exhibitor: Shenzhen York Technology Co.
Product details
E-6 six function verification slot
The E-6 provides an additional wide operating range, which is easy to use and convenient to carry. As one of the ISOCAL-6 series, E-6 can be used as a dry furnace, liquid tank, blackbody source for infrared thermometers, surface temperature sensor calibrator, and ITS-90 fixed point calibrator for several mK (0.001 ℃). There are two models of E-6, Basic (Type B) and On site (Type S). The B-type comes with a sophisticated temperature controller that displays the set temperature and dry body temperature. The S-type has a built-in digital indicator that can be connected to an external temperature sensor, providing better accuracy and traceability. When using the dry body furnace function, we recommend choosing the on Site dry body calibration furnace and selecting the on-site precision temperature probe. It can be used as an external standard for upper level traceability and calibration to establish an on-site temperature calibration laboratory. The UK based company Assunt uses an external probe connected to the on-site indicator to compensate for temperature gradients and load errors. We recommend the option of embedded independent indicator (field type) and standard platinum resistance thermometer to make it a completely independent calibration laboratory. Using the fixed point method, the calibration slot provides unprecedented accuracy of ± 0.001 ℃; By using a stirred tank method, the accuracy can reach ± 0.005 ℃ (compared to calibration)




Indicator E-6 type
Temperature range: Below the ambient temperature of 65 ℃~+140 ℃
Absolute minimum temperature: -55℃
Absolute stability exceeding 30 minutes
1 Dry body verification furnace: ±0.03℃
2 Mixing liquid tank: ±0.025℃
3 Mixing ice/water tank: ±0.001℃
4 Blackbody Furnace: ±0.3℃
5 Surface temperature sensor calibrator: ±0.5℃
6 1TS-90 fixed point equipment: ±0.0005℃
Cooling time 250 ℃ to 0 ℃ for 15 minutes
Heating time -30 ℃ to 250 ℃ for 15 minutes
Verification capacity: 35mm diameter, 160mm depth
uniformity: ±0.018℃
Display resolution -19.99 to 99.99 0.01℃
-55.0 to –20.0 0.1℃
100 to 140 0.1℃
Indicator unit: ℃,℉, K
External dimensions: 322mm(H)×176mm(W)×262mm(D)
Standard input casing Six holes: 1 × 9.5mm; 1×8.0mm
2×6.4mm; 2×4.5mm
All 157mm deep
Weight: 14kg

Ordering reference
Fortunately, users do not need to purchase the entire verification package at once. For example, you can purchase a dry body calibration furnace first and add accessories according to your own needs in the future. Due to the replaceability of various attachments, ISOCAL-6 has greater flexibility.
option function model
1 Dry body verification furnace E-6B
2 Mixing liquid tank Basic type with temperature controller
3 Mixing ice/sink E-6S
4 Black body furnace On site type with temperature controller and indicator
5 Surface thermometer calibration furnace E-6SN
6 ITS-90 fixed point equipment On site type, equipped with temperature controller, indicator, NAMAS certificate and standard PT100 probe

Options
1. User customized casing or replacement casing
2 liquid containers for oil or ice/water
3 different liquids
4 blackbody targets
5 Surface temperature sensor calibration sleeve
6 fixed point rooms

Water triple point room
Gallium melting point chamber
Indium melting point chamber


7 Carrying Boxes
8 standard probes
9 Sensors/thermometers for options 1 and 2
10 RS232 communication or RS422 communication



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!