Short wave mid low temperature infrared scanning thermal imaging instrument
PYROLINE 320N protection
The shell includes a water-cooled jacket, a blower, and optical glass,
Temperature resistance -25~150 ℃
Scanning speed: 256Hz (line/second)
Short wave medium low temperature scanning imaging instrument: 450-1200 ℃
feature
1) Precise non-contact temperature measurement, ultra wide temperature measurement range: 450~1200 ° C
2) Indium gallium arsenide infrared array detector, pixel 320 × 1
3) Multiple lenses 56 °, 34 °, 24 °, 12 °, electrically adjustable focus
4) Spectral range 1.4 μ m~1.6 μ m
5) Gigabit Ethernet communication interface (1 GBit/s)
6) Measurement frequency 256 lines per second (256Hz)
7) Large dynamic range, 16 bit analog-to-digital conversion
8) Housing protection (IP65) including water-cooled jacket blower and optical glass
9) Can be integrated into existing user system solutions, allowing for hardware and software adjustments
Technical data
model |
PYROLINE 320N / 256Hz protection |
Spectral Range 1 |
1.4 μm ~ 1.6 μm |
Temperature measurement range 1 |
450~1200°C |
NETD2,3 |
< 1 K (450 °C, 256Hz) 5 |
field of view |
56 °, 34 °, 24 °, 12 °, electrically adjustable focus |
detector |
Indium gallium arsenide infrared array detector (320 × 1 pixel) |
Measurement error 3 |
1% measurement value (° C) |
Maximum frequency |
256Hz |
response time |
Internal 3.9ms, optional: 2/measurement frequency |
communication interface |
Gigabit Ethernet (real-time, 256Hz), electrically isolated digital input (trigger) and digital output (alarm) |
terminal block |
Circular plug HR10A (12 core, power supply, digital input and output), circular plug M12A (Ethernet) |
power supply |
12~36 V DC, Usually 10 VA |
weight |
About 4.2 kg |
shell |
Industrial enclosure IP65, stainless steel, with air blower, IP65, And water-cooled jacket, diameter 110mm, length 183mm, with connector |
Head size 279 mm, maximum water pressure 6 bar, maximum air pressure 2 bar, with protective window | |
Operating temperature |
-10~50 ° C (without water cooling), -25~150 ° C (with water cooling) |
Storage conditions |
-20~70 ° C, maximum relative humidity of 95% |
software |
Windows ® The control and imaging software PYROLOFT can be adjusted appropriately according to user requirements |
Scope of supply |
PYROLINE 320N protection, Calibration certificate, operation manual, PYROLOFT Compact software |
Note: 1. Other temperature ranges shall be provided as required. 2. Temperature differences such as noise shall be provided. Three technical indicators have been calibrated using a blackbody furnace, with a calibrated ambient temperature of 25 ° C. | |
German DIAS Infrared Company's 12 shortwave infrared scanning thermal imagers: