Ultra high speed shortwave mid low temperature infrared scanning thermal imager
PYROLINE HS320N protection
Scanning speed: 2000Hz
Ultra high speed shortwave low temperature scanning imaging instrument: 450-1200 ℃
feature
1) Precise non-contact temperature measurement, ultra wide temperature measurement range: 450~1200 ° C
2) Indium gallium arsenide infrared array detector, pixel 320 × 1
3) Multiple lenses 56 °, 34 °, 24 °, 12 °, electrically adjustable focus
4) Spectral range 1.4 μ m~1.6 μ m
5) Gigabit Ethernet communication interface (1 GBit/s)
6) Measurement frequency of 2000 lines per second (2000Hz)
7) Large dynamic range, 16 bit analog-to-digital conversion
8) Equipped with water-cooling and blower casing protection (IP65)
9) Can be integrated into existing user system solutions, allowing for hardware and software adjustments
Technical data
model |
PYROLINE HS320N / 2000Hz protection |
spectral range1 |
1.4 μm ~ 1.6 μm |
Temperature measurement range1 |
450~1200°C |
NETD2,3 |
< 1 K (450 °C, 2000Hz) 5 |
field of view |
56 °, 34 °, 24 °, 12 °, electrically adjustable focus |
detector |
Indium gallium arsenide infrared array detector (320 × 1 pixel) |
measurement error3 |
2% measurement value (° C) (<1100 ° C) |
Maximum frequency |
2000Hz |
response time |
0.5ms , Optional: 2/Measurement frequency |
communication interface |
Gigabit Ethernet (real-time, 2000Hz), electrically isolated digital input (trigger) and digital output (alarm) |
terminal block |
Circular plug HR10A (12 core, power supply, digital input and output), circular plug M12A (Ethernet) |
power supply |
12~36 V DC, Usually 10 VA |
weight |
About 4.2 kg |
shell |
Stainless steel casing, IP65, 65 mm (L) × 160 mm (W) × 79 mm (H), (size without connector and lens) optional all-weather casing with gimbal |
Operating temperature |
-25~150 ° C (with water cooling and blowing), -10~50 ° C without water cooling and blowing |
Storage conditions |
-20~70 ° C, maximum relative humidity of 95% |
software |
Windows ® The control and imaging software PYROLOFT can be adjusted appropriately according to user requirements |
Scope of supply |
PYROLINE HS320N protection, Calibration certificate, operation manual, PYROLOFT Compact software |
Note: 1. Other temperature ranges shall be provided as required. 2. Temperature differences such as noise shall be provided. Three technical indicators have been calibrated using a blackbody furnace, with a calibrated ambient temperature of 25 ° C. | |
German DIAS Infrared Company's 12 shortwave infrared scanning thermal imagers: