English

Chengdu Chuanhongke Biotechnology Co., Ltd
Home>Products>Shanghai Yiheng Microbial * Filter BPN-170RWP Water Jacket CO2 Constant Temperature Incubator
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15802855108
  • Address
    No. 12, 7th Floor, No.2 Kehua North Road, Wuhou District, Chengdu City
Contact Now
Shanghai Yiheng Microbial * Filter BPN-170RWP Water Jacket CO2 Constant Temperature Incubator
Chengdu Chuanhongke Biotechnology Co., Ltd. provides one-stop solutions for water jacket CO2 constant temperature incubator manufacturers and Shanghai
Product details

Chengdu Chuanhongke Biotechnology Co., Ltd. provides one-stop service for youManufacturer of water jacket CO2 constant temperature incubatoras well asShanghai YihengModel of water jacket CO2 constant temperature incubatorincludeShanghai YihengPrice of water jacket CO2 constant temperature incubatorThe company has professional technical engineers who are fully responsible for the installation, commissioning, technical training, and after-sales service support of the Shanghai Yiheng water jacket CO2 constant temperature incubator!

  Shanghai Yiheng has a microbial high-efficiency filter BPN-170RWPWater jacket CO2Constant temperature incubatorProduct features:

◆ Touch screen controller

Adopting a large touch screen display, the screen replaces the traditional button based operation method, making operation simple and program editing easy. The controller operation interface is available in both Chinese and English.

It can display real-time operating curves and has a curve summary function. It can directly view the changes in temperature, humidity, CO2 concentration curves, abnormal alarms, and door opening and closing information during the same time period.

After inputting the data and experimental conditions, the controller has a screen lock function to avoid human touch instead of normal shutdown.

The 72 hour machine operation record query function facilitates users to track and trace historical operation information for abnormal situations.

Equipped with RS-485 communication interface, it can be programmed on a computer to monitor the experimental process and perform functions such as power on/off.

CO2 concentration control system

Imported infrared (IR) sensor control

During the experiment, it is necessary to frequently open the box door, and infrared sensors are an ideal choice. The imported infrared (IR) sensor selected by Yiheng is highly sensitive to changes in CO2 concentration and is not affected by other internal conditions of the incubator. It has high measurement accuracy and avoids the influence of temperature and humidity inside the incubator on traditional thermal conductivity probes when monitoring CO2 concentration. If the door is opened for 30 seconds and then closed, the set concentration of CO2 can be restored to 5% within ≤ 3 minutes. Even in situations where multiple people need to frequently open and close the door, the CO2 concentration inside the box can still be quickly, stably, and uniformly maintained.

Temperature control//monitoring system

A. Incubator temperature control system

Pt100 temperature detector ensures accurate temperature inside the box. The heating power can be adjusted in real time by the difference between the actual temperature inside the box and the set temperature, ensuring the accuracy of the actual temperature inside the box. The experimental temperature can be restored within 3 minutes after the user opens and closes the door for sampling and layout.

B. Door temperature heating system

The outer box door has a heating function, and the door temperature follows the box temperature slightly higher than the box temperature, which can effectively prevent the glass door from producing condensation water, facilitate observation of the experimental process, and avoid the possibility of microbial contamination caused by the condensation water produced by the glass door.

C. Environmental temperature monitoring system

An independent ambient temperature detector that can automatically adjust the CO2 incubator heating system based on changes in the ambient temperature during the experiment to avoid temperature overshoot inside the incubator.

D. Overtemperature protection system

A backup temperature control system independent of the CO2 incubator temperature control system. When the incubator temperature control system malfunctions and causes temperature loss, and the temperature in the working chamber reaches the set limit of the controller, the overtemperature protection system will automatically cut off heating and sound an alarm.

E. Power outage alarm system

Real time monitoring of the power supply status of the incubator. When there is a power outage or loss, an audible and visual alarm signal will be immediately issued to ensure safe and reliable operation of the incubator without accidents.

Sterilization system

A. 90 ℃ High Temperature Wet Heat Sterilization System (RHP)

It can thoroughly sterilize the interior (including temperature sensors, carbon dioxide concentration sensors, fans, partitions, and brackets) with high temperature and humidity, completely eliminating microbial contamination caused by bacteria, molds, mycoplasma, and other microorganisms on cell culture, providing users with a safe experimental environment.

Easy to operate: Users only need to press the (sterilization start) button on the control panel, and this sterilization system can thoroughly sterilize all components inside the box, including temperature sensors, carbon dioxide concentration sensors, fans, partitions, and brackets. The entire sterilization process takes 18 hours to ensure comprehensive and efficient sterilization.

B. UV Sterilization System (RWP)

The ultraviolet sterilization lamp is located at the top and rear of the box, which can regularly sterilize the inside of the box, effectively killing water vapor floating bacteria in the circulating air and humidification water tray or bottom slope water tray inside the box, thereby effectively preventing contamination during cell culture.

Automatic control of circulating fan speed

The speed of the circulating fan can be automatically controlled. When the temperature inside the box is at a constant temperature, the speed will decrease and the circulating wind speed will be adjusted to a suitable speed for cell growth, avoiding sample evaporation caused by excessive air volume during the experiment.

Efficient filter

A. Microbial high-efficiency filter

The CO2 inlet is equipped with a microbial high-efficiency filter, which has a filtration efficiency of up to 99.99% for particles with a diameter ≥ 0.3 μ m, effectively filtering bacteria and dust particles in CO2 gas.

B. HEPA high-efficiency filter (optional)

The gas quality inside the CO2 incubator is an important indicator for measuring the cell culture environment. HEPA high-efficiency filters can effectively filter out bacteria and dust particles from the outside air, eliminate and prevent cross contamination between the outside air and the incubator, and keep the incubator in a sterile state at all times. After the door is closed for 5 minutes, the air quality inside the box can quickly return to a level 100 cleanliness. HEPA high-efficiency filters are easy to disassemble and assemble without the need for tools.

  Shanghai Yiheng BPN-170RWPWater jacket CO2Constant temperature incubatorSecurity function:

Alarm for high, low, and over temperature

  

Box temperature sensor malfunction alarm

  

Door temperature sensor malfunction alarm

  

Overtemperature sensor malfunction alarm

  

Alarm for high or low CO2 concentration

  

Power outage alarm

  

Independent temperature limit alarm

  

Alarm if the door opening time is too long

  

Disinfection and sterilization status prompt

  

Data recording and fault diagnosis display (optional)

All data can be downloaded to the computer through the RS485 port and saved. In case of any failure, the data can be retrieved from the computer and diagnosed in time.

Wireless alarm system (excluding mobile phone) (optional)

If the device user is not on site, when the device malfunctions, the system promptly collects the fault signal and sends it to the designated recipient's mobile phone via SMS to ensure timely troubleshooting, recovery testing, and avoid accidental losses.

  Shanghai Yiheng BPN-170RWPWater jacket CO2Constant temperature incubatorTechnical parameters:

Model number

  

BPN-170RWP

  

Power supply voltage

  

AC220V/50Hz

  

Input power

  

700W

  

Heating method

  

Water jacket type

  

Temperature control range

  

RT+5-50 ℃

  

Working environment temperature

  

+5-30 ℃

  

Temperature fluctuation

  

± 0.1 ℃

  

CO2 control range

  

0-20%

  

CO2 control accuracy

  

± 0.1% (infrared sensor)

  

CO2 recovery time

  

(Recovery to 5% within 30 seconds of opening the door) ≤ 3 minutes

  

Temperature recovery

  

(30 seconds to recover to 37 ℃ upon opening the door) ≤ 8 minutes

  

Relative humidity

  

Natural evaporation ≥ 90% (can be equipped with relative humidity digital display)

  

Volume

  

170L

  

Inner container size (mm) W × D × H

  

530 × 460 × 720

  

Dimensions (mm) W × D × H

  

684 × 700 × 960

  

Load carrier (standard)

  

3 pieces

  

UV lamp sterilization

  

UV disinfection

  

Note: All technical data are for equipment testing in a 25 ℃ environment.

Optional parts:

RS485/232 interface and communication software

¥ 600

Specialized carbon dioxide pressure reducing valve

¥ 600

Humidity display system

¥ 3500

Wireless alarm system (SMS alarm system)

¥ 2500

HEPA high-efficiency filter system

¥ 2500

Provide 3Q verification and calibration services

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!