A sensor based water quality online monitoring device is an online instrument composed of a multifunctional display and one or more detection sensors that can real-time detect pH value, conductivity, temperature, turbidity, dissolved oxygen, and other contents.The system has a wide range of application fields,Applicable toIndustrial and domestic wastewaterDrinking water sourceAgricultural irrigation water and aquaculturewaterclassReal time monitoring of water quality in various fieldsUsers can choose between a single sensor monitor or a multi parameter monitor according to their needs.
Functional features:
Ø1. Color LCDTouch screen operation,Human computer interface friendly
Ø2PLC control, can set alarm output,Easy to use for real-time monitoring of water quality conditions
Ø3. ProvideFree local computer display software,Convenient for users to save data in multiple ways
Ø4Support various typesRs485 communication water quality detection sensor,Multi parameter measurement can be achieved, and monitoring indicators can be flexibly selected
Ø5. Equipped with wireless communication function,GPRS wireless data transmission
Ø6Optional mobile phoneAPP software and remote access computer software
Ø7. Equipped with multiple sensor interfaces, expandable to monitor up to 13 water quality indicators
Technical parameters:
product name |
Water quality online monitoring instrument display terminal UPC-ZD1200 |
||||||||
major function |
Color LCD touch screen with wireless communication function, capable of connecting up to 12 online sensors |
||||||||
product name |
Water quality online monitoring instrument display terminal UPC-ZD400 |
||||||||
major function |
Color LCD touch screen, capable of connecting up to 4 online sensors |
||||||||
The following are optional online monitoring sensors that can be connected to the above terminals |
|||||||||
product name |
Conventional five parameter online sensor UPTT-CG500 |
||||||||
parameter |
PHprice |
conductivity |
Fluorescence method for dissolved oxygen |
temperature |
turbidity |
||||
range |
0~14pH |
0.01uS/cm~400mS/cm Or 0-100 PSU |
0~20.00mg/L Or 0-200% saturation |
0~60℃ |
0.1~1000NTU Or 0.01~20NTU |
||||
resolution |
0.01pH |
0.01μS/cm,0.1μS/cm, 0.1mS/cm, 0.1PSU |
0.01mg/L |
0.1℃ |
0.1NTUOr 0.01 NTU |
||||
accuracy |
±0.1pH |
±1.5%F.S. |
±1%F.S. |
0.1℃ |
<5%Or ± 0.3NTU |
||||
operation temperature |
0~45℃ |
||||||||
Working pressure |
<0.1MPa |
||||||||
power supply |
12VDC~24VDC±10% |
||||||||
output signal |
Rs485(Modbus/RTU) |
||||||||
Installation method |
3/4" NPTThreaded or immersion type |
Investment style |
|||||||
product name |
Chlorophyll A online sensor UPTT-YLS |
||||||||
range |
0~400ug/L |
resolution |
0.1ug/L |
||||||
accuracy |
±5%F.S. |
operation temperature |
0~40℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Submerged installation |
||||||||
product name |
Blue green algae online sensor UPTT-LLZ |
||||||||
range |
100~300.000cells/mL |
resolution |
0.01ug/L |
||||||
accuracy |
1ppb± 5% of the corresponding signal level of Rhodamine WT dye |
operation temperature |
0~45℃ |
||||||
Working pressure |
<0.4MPa |
Liquid receiving material |
SS316L |
||||||
power supply |
12VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Submerged installation |
||||||||
product name |
Ammonia nitrogen online sensorUPTT-NHL |
||||||||
range |
0~100mg/L |
resolution |
0.01mg/L |
||||||
accuracy |
± 10% F.S. or ± 2mg/L |
operation temperature |
0~40℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Submerged installation |
||||||||
product name |
Ammonia nitrogen online sensorUPTT-NHH |
||||||||
range |
0~1000mg/L |
resolution |
0.01mg/L |
||||||
accuracy |
± 10% F.S. or ± 2mg/L |
operation temperature |
0~40℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Submerged installation |
||||||||
product name |
CODOnline sensorsUPTT-COD |
||||||||
range |
0~100mg/L |
resolution |
0.01mg/L |
||||||
accuracy |
± 10% F.S. or ± 2mg/L |
operation temperature |
0~40℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Submerged installation |
||||||||
product name |
Dissolved oxygen online sensorUPTT-DOG |
||||||||
range |
0~20.0mg/L 0~200saturation |
resolution |
0.01mg/L |
||||||
accuracy |
±1%F.S. |
operation temperature |
0~45℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
PHOnline sensorsUPTT-PHJ |
||||||||
range |
0~20.0mg/L 0~200saturation |
resolution |
0.01mg/L |
||||||
accuracy |
±1%F.S. |
operation temperature |
0~45℃ |
||||||
Working pressure |
<0.1MPa |
Liquid receiving material |
POM |
||||||
power supply |
5~12VDC ±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
ORPOnline sensorsUPTT-ORP |
||||||||
range |
-1500~1500mV |
resolution |
1mV |
||||||
accuracy |
±3mV |
operation temperature |
0~45℃ |
||||||
Working pressure |
<0.1MPa |
Installation method |
3/4" NPTThreaded or immersion type |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
Conductivity online sensorUPTT-DDL |
||||||||
range |
0.01uS/cm~400mS/cm Or 0-100 PSU (range customizable) |
resolution |
0.01μS/cm, 0.1μS/cm, 0.1mS/cm, 0.1PSU |
||||||
accuracy |
±5%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
Salinity online sensorUPTT-YDJ |
||||||||
range |
0~70PSU |
resolution |
0.1PSU |
||||||
accuracy |
±1.5%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
Turbidity online sensorUPTT-ZDJ |
||||||||
range |
0.1~1000NTU or 0.01~20NTU |
resolution |
0.1NTUOr 0.01 NTU |
||||||
accuracy |
<5%Or ± 0.3NTU |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Investment style |
||||||||
product name |
Suspended solids online sensorUPTT-SSJ |
||||||||
range |
0~2000mg/L |
resolution |
0.1 mg/L |
||||||
accuracy |
±5%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Investment style |
||||||||
product name |
Residual chlorine online sensorUPTT-YLJ |
||||||||
range |
0~2.0ppm |
resolution |
0.001 ppm |
||||||
accuracy |
±1%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
Investment style |
||||||||
product name |
Chloride ion online sensorUPTT-LLZJ |
||||||||
range |
0~20000mg/L |
resolution |
1.0mg/L |
||||||
accuracy |
±10%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
Fluorine ion online sensorUPTT-FLZJ |
||||||||
range |
0~100mg/L |
resolution |
0.1mg/L |
||||||
accuracy |
±10%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
nitrate nitrogenOnline sensorsUPTT-ENG |
||||||||
range |
Nitrate nitrogen 0~50mg/L |
resolution |
0.1mg/L |
||||||
accuracy |
±5%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |
||||||
Installation method |
3/4" NPTThreaded or immersion type |
||||||||
product name |
Static pressure liquid level sensorUPTT-YWY |
||||||||
range |
0~100m |
resolution |
0.1m |
||||||
accuracy |
±1.5%F.S. |
operation temperature |
0~50℃ |
||||||
power supply |
12VDC~24VDC±10% |
output signal |
Rs485(Modbus/RTU) |