VIP member
Semi automatic acid steaming cleaning machine UP-52
The semi-automatic acid distillation cleaning machine UP-52 consists of a tank body, a control module, and a graphite heating plate, which can clear a
Product details
product overview
The semi-automatic acid distillation cleaning machine UP-52 consists of a tank body, a control module, and a graphite heating plate, which can clear all trace metal pollutants soluble in acid on the surface of the vessel, ensuring the accuracy of trace analysis and ultra trace analysis.

Working principle
Utilize the sub boiling state of acid to generate pure acid vapor. Through natural condensation of acid vapor and contact with the surface of the vessel, it condenses into liquid droplets and flows back into the barrel under gravity, repeating the cycle. Dissolve and remove metal ions from the surface of the vessel to achieve the purpose of cleaning.
performance parameter
Performance advantages of semi-automatic acid steaming cleaning machine
1. The cleaning machine adopts TFM PTFE raw material integrated molding, and the heating part is treated with high-purity graphite Gatteflon spray coating;
2. Adopting a hollow structure to support the steam nozzle, imported PFA material;
3. The bottom of the graphite furnace is insulated, and the bottom temperature does not exceed 60 ℃ (when the furnace temperature is 180 ℃);
4.5-inch touchscreen (wired) PID controller, capable of stepwise temperature control and temperature rise rate control;
5. Custom temperature curve, can save custom methods;
6. Over temperature protection and timed automatic heating stop function;
7. There is a manual acid discharge valve at the bottom, and when the acid discharge valve is opened, the bottom has a slope that can automatically drain;
8. Supports WIFI wireless control (optional), keeping control components away from acidic environments;
9. The cleaned acid can be reused;
10. During acid drainage, an acid drainage valve can be used to drain the acid;
11. The surface contact acid vapor concentration of the cleaning container is 100%. All internal contact parts are made of high-purity PTFE material, and the cleanliness can reach PPB level.
Cleaning object
It can clean and disinfect various shapes and sizes of laboratory vessels made of materials such as glass, ceramics, metal, plastic, and rubber, including culture dishes, glass slides, pipettes, digestion tanks, chromatography bottles, test tubes, triangular bottles, conical bottles, beakers, flasks, measuring cylinders, volumetric flasks, cylinder flasks, serum bottles, funnels, etc.

application area
·Government laboratories: quality inspection, forensic, commercial inspection, disease prevention and control center, environmental monitoring station, food and drug supervision and administration bureau, etc.
·Enterprise nature laboratory: food, cosmetics, biopharmaceuticals, chemicals, dairy products, petrochemicals, etc.
·Third party testing agency laboratories: such as SGS in Switzerland, Intertek in the UK, and domestic third-party testing agencies.
·Research institutes: such as the School of Medicine, the Institute of Biology, the Institute of Geochemistry, the Institute of Materials Science, and the Institute of Agriculture.
Usage
1. Preparation before use
Before use, check whether the screws and nuts of each part of the semi-automatic acid distillation reflux cleaner are loose. The pump eccentric axle box has been filled with 30 # or 40 # engine oil, and the oil level needs to be checked.
2. Inlet pipe connection
Insert the inlet hose onto the inlet joint of the pump body, then attach the throat clamp and tighten the screws on the clamp to ensure a secure and leak free connection. Then, according to the water source, place the other end on the tap or into the water supply pool. The inlet pipe should be equipped with a filter to prevent impurities from damaging the high-pressure pump.
3. Water outlet pipe connection
Connect the insertion connector end of the high-pressure hose to the quick change connector on the outlet of the machine; The other end is connected to the threaded joint on the trigger valve of the spray gun. Attention: High pressure water pipes should not be twisted, and should be stretched and straightened as much as possible.
4. Power connection
Firstly, it is necessary to ensure that the power supply voltage is consistent with the label requirements. The connection of the fixed power supply used in the semi-automatic acid steaming cleaning machine UP-52 should be carried out by professionals and should comply with the requirements of GB/T16895. If an extension power cord is used, the plug and socket should have a waterproof structure.
The semi-automatic acid distillation cleaning machine UP-52 consists of a tank body, a control module, and a graphite heating plate, which can clear all trace metal pollutants soluble in acid on the surface of the vessel, ensuring the accuracy of trace analysis and ultra trace analysis.

Working principle
Utilize the sub boiling state of acid to generate pure acid vapor. Through natural condensation of acid vapor and contact with the surface of the vessel, it condenses into liquid droplets and flows back into the barrel under gravity, repeating the cycle. Dissolve and remove metal ions from the surface of the vessel to achieve the purpose of cleaning.
performance parameter
PRODUCT MODEL | UP-52 |
Number of bracket positions | 60 seats (customizable) |
Temperature range | 0~240 ℃ |
Pressure relief valve | Overvoltage protection, automatic pressure relief protection. |
Processing capacity | ≥ 60 55 mL digestion reaction tanks (once) |
Graphite heater power | ≤2.2kw |
Acid distillation ultra clean cleaning environment | sealed |
Cooling method | Natural air cooling without the use of cooling water. |
Applicable reagents | Hydrofluoric acid, hydrochloric acid, nitric acid, water |
clean time | <4 hours (regular) |
Cleaning scope | Suitable for cleaning all reactors used in trace and ultra trace analysis. |
Performance advantages of semi-automatic acid steaming cleaning machine
1. The cleaning machine adopts TFM PTFE raw material integrated molding, and the heating part is treated with high-purity graphite Gatteflon spray coating;
2. Adopting a hollow structure to support the steam nozzle, imported PFA material;
3. The bottom of the graphite furnace is insulated, and the bottom temperature does not exceed 60 ℃ (when the furnace temperature is 180 ℃);
4.5-inch touchscreen (wired) PID controller, capable of stepwise temperature control and temperature rise rate control;
5. Custom temperature curve, can save custom methods;
6. Over temperature protection and timed automatic heating stop function;
7. There is a manual acid discharge valve at the bottom, and when the acid discharge valve is opened, the bottom has a slope that can automatically drain;
8. Supports WIFI wireless control (optional), keeping control components away from acidic environments;
9. The cleaned acid can be reused;
10. During acid drainage, an acid drainage valve can be used to drain the acid;
11. The surface contact acid vapor concentration of the cleaning container is 100%. All internal contact parts are made of high-purity PTFE material, and the cleanliness can reach PPB level.
Cleaning object
It can clean and disinfect various shapes and sizes of laboratory vessels made of materials such as glass, ceramics, metal, plastic, and rubber, including culture dishes, glass slides, pipettes, digestion tanks, chromatography bottles, test tubes, triangular bottles, conical bottles, beakers, flasks, measuring cylinders, volumetric flasks, cylinder flasks, serum bottles, funnels, etc.

application area
·Government laboratories: quality inspection, forensic, commercial inspection, disease prevention and control center, environmental monitoring station, food and drug supervision and administration bureau, etc.
·Enterprise nature laboratory: food, cosmetics, biopharmaceuticals, chemicals, dairy products, petrochemicals, etc.
·Third party testing agency laboratories: such as SGS in Switzerland, Intertek in the UK, and domestic third-party testing agencies.
·Research institutes: such as the School of Medicine, the Institute of Biology, the Institute of Geochemistry, the Institute of Materials Science, and the Institute of Agriculture.
Usage
1. Preparation before use
Before use, check whether the screws and nuts of each part of the semi-automatic acid distillation reflux cleaner are loose. The pump eccentric axle box has been filled with 30 # or 40 # engine oil, and the oil level needs to be checked.
2. Inlet pipe connection
Insert the inlet hose onto the inlet joint of the pump body, then attach the throat clamp and tighten the screws on the clamp to ensure a secure and leak free connection. Then, according to the water source, place the other end on the tap or into the water supply pool. The inlet pipe should be equipped with a filter to prevent impurities from damaging the high-pressure pump.
3. Water outlet pipe connection
Connect the insertion connector end of the high-pressure hose to the quick change connector on the outlet of the machine; The other end is connected to the threaded joint on the trigger valve of the spray gun. Attention: High pressure water pipes should not be twisted, and should be stretched and straightened as much as possible.
4. Power connection
Firstly, it is necessary to ensure that the power supply voltage is consistent with the label requirements. The connection of the fixed power supply used in the semi-automatic acid steaming cleaning machine UP-52 should be carried out by professionals and should comply with the requirements of GB/T16895. If an extension power cord is used, the plug and socket should have a waterproof structure.
keywords