Self purifiers/air purifiers include mobile air purifiers and ceiling mounted air purifiers
Air purifier is an air purification unit that provides a locally clean working environment. Self purifiers, also known as air purifiers, are made of stainless steel or cold-rolled steel plates coated with baking paint. The air purifier mainly consists of a primary air filter, a fan, a high-efficiency air filter, and a static pressure box. The outer shell is treated with steel plate spray coating, and the box is covered with sponge. The whole machine has low noise, simple structure, and easy use. It can be installed for outdoor air self circulation. Air purifier is a simple indoor purification and air supply device.
Introduction to Mobile Air Purifier:
1. The outer shell of the mobile air purifier is entirely made of cold-rolled steel plate baked paint, consisting of a fan, primary filter, supply air static pressure box, high-efficiency filter, and flow equalization plate. And it is equipped with a wind speed adjuster, which can adjust the wind speed according to the actual situation. The purification level air outlet can reach up to 1000 levels.
2. The air purifier can achieve a cleanliness level of 10000 on the workbench (approximately 10000 particles with a particle size of ≥ 0.5um in 1ft3 air).
The lower part of the air purifier unit is equipped with movable casters, which can be moved to the desired position as required and fixed. It is flexible and convenient to use, and adopts a variable air volume fan system with multiple speed controls, selected step by step, to ensure that the wind speed in the local working area is always in the ideal state.
3. A mobile air purifier is an air purification device that provides a locally clean working environment, consisting of a primary air filter, a fan, a high-efficiency air filter, and a casing. The shell is made of color steel plate and treated with surface paint. It has a simple structure, is easy to use, and can circulate indoor air after installation. It is suitable for use in environments with low cleanliness levels of 1000-100000 and frequent changes in working positions. For use in environments with low cleanliness levels ranging from 1000 to 300000 and frequent changes in working positions, two types of self-cleaning devices can be made as needed: mobile (vertical) or ceiling mounted.
4. Air purifiers are now widely used in small areas such as sterile rooms, laboratories, purified water, and filling plants for air purification in filling rooms; Air purification in beverage factories, dairy products factories, food factories, distilleries, and other industries. It is an ideal choice for QS certification equipment in food factories.
5. The outer shell of the air purifier is treated with steel plate spray coating, and it comes with its own fan, high-efficiency filter screen, supply air static pressure box, high-efficiency filter, and uniform flow plate. And it is equipped with a wind speed adjuster, which can adjust the wind speed according to the actual situation. The purification level air outlet can reach up to 1000 levels. On the workbench, it can achieve a cleanliness level of 10000 (i.e. about 10000 particles of ≥ 0.5um in 1ft3 air). The lower part of the air self-cleaning unit is equipped with a movable wheel and an adjustable jack, which can be moved to the desired position as required and fixed. It is flexible and convenient to use, and adopts a variable air volume fan system with multiple speed controls, selected step by step, to ensure that the wind speed in the local working area is always in the ideal state.
6. The air purifier device is suitable for use in environments that require cleanliness levels ranging from 10000 to 100000.
Ceiling mounted air purifier:
Hang the self-cleaning device on the ceiling of the room with hanging bars. The self-cleaning device sucks in the air from the upper part of the ceiling and filters it through primary and high efficiency before sending it into the room. The room can achieve the required clean environment, but it is required that the walls, ceiling, and floor around the room are well sealed and do not produce dust. Ensure that the requirements for air purification environment in small rooms are met.
Characteristics of air purifier:
1. It can be used alone or connected in multiple ways to form a clean area.
2. Compared with civil or prefabricated Class 100 cleanrooms, it has the advantages of low investment, quick results, easy installation, and low operating costs.
3. The size can be adjusted according to the user's height.
Model/specification size and technical parameters of air purifier:
Precautions for using air purifiers:
1. The installation location of air purifier equipment should be far away from distant high-speed sources and seismic sources. It should be installed in various levels of purification plants or air conditioning plants, and can be installed horizontally or vertically as needed. During installation, a 5mm thick latex sponge sealing gasket frame should be placed on the installation surface to ensure airtightness.
2. The size of the installation hole for the air purifier is determined based on the external dimensions of the purifier.
3. If a pressure regulator is used in the air purifier equipment, the voltage of the regulator can be adjusted without changing the average wind speed of the air outlet surface, thus using the self-cleaning device most economically and improving the service life of the high-efficiency filter.
4. To ensure the cleanliness of the purification area, the machine should be turned on 15 minutes before each use.
5. The clean air blowing surface should face the work area that needs to be purified, and large areas of objects should be avoided from blocking during this period. Efforts should be made to avoid actions that significantly disrupt laminar flow in the purification area.
6. According to the cleanliness level of the environment, the non-woven filter material in the top pre filter should be removed and cleaned regularly, with an interval of 3-6 months. In general, when the non-woven filter material in the pre filter turns black, it can be removed for cleaning or replaced.
7. Regularly (usually twice a month) use the Y9-4 dust particle counter to measure the cleanliness of the room or workspace where this equipment is installed. If it does not meet the technical specifications, the high-efficiency filter should be replaced. The service life of the high-efficiency filter is 9600 hours
8. When replacing the high-efficiency filter, the front pressure frame of the purifier must be removed, and the high-efficiency filter should be taken out. When replacing the high-efficiency filter with a new one, the arrow on the high-efficiency filter should point in the direction of gas flow.
9. After replacing the high-efficiency filter, the dust particle counter should be scanned to detect leaks, paying special attention to whether the surrounding borders are in good condition.
10. Electrical faults require professional maintenance.
11. The operating temperature of air purifier equipment shall not exceed 50 ℃, and the use of open flames is strictly prohibited.