On December 1, 2017, the National Energy Administration made corresponding adjustments to the qualification equipment for power testing. The qualification equipment for testing in each province and region is the same, and some equipment that is not commonly used by power enterprises in actual work is omitted. Huatian Power briefly introduced the new version of the construction equipment selection guide for the second level power facility license for installation (repair, testing) testing.
Obtaining a second level installation (repair, testing) license, one can engage in the installation, maintenance, or testing activities of power facilities with voltage levels below 220 kV.
To learn about the application materials and filling specifications for the installation, maintenance, and testing of power facility licenses, you can click on "Application Specifications" to browse.
Product nickname: Secondary testing instrument, secondary testing equipment, testing instrument equipment, secondary testing configuration table, secondary testing equipment, and selection table for secondary testing and inspection equipment.
Serial Number | Name of machinery and equipment | unit | quantity | specifications | model |
one | High voltage generating equipment | ||||
1 | DC high voltage generator | cover | 1 | DC:250kV/5mA | ZGS-250kV/5mA |
2 |
Power frequency withstand voltage test device |
cover | 1 | AC:10kVA/100kV | GYD-10kVA/100kV |
cover | 1 | AC:5kVA/50kV | YDJ-5kVA/50kV | ||
3 | Complete set of equipment for frequency conversion series resonance test | cover | 1 | 2000kVA/500kV/5A, 30-300Hz |
XZB-2000kVA/400kV |
4 | Induction voltage withstand test device | cover | 1 | 5kVA/360V 150Hz | SFQ-5kVA/500V |
two | Electrical measuring instruments | ||||
1 |
High voltage dielectric loss tester |
tower |
2 |
1. The accuracy of medium measurement is 1% 2. The capacitance accuracy is 0.5% 3. Anti interference frequency conversion |
JS-H |
2 | Loop resistance tester | tower | 2 | DC:≥100A | HLY-100A |
3 | Transformer volt ampere characteristic tester | tower | 1 | 2200V/5A | FA-103 |
4 | Ground Resistance Tester | tower | 1 | Frequency difference method | JD-H |
5 | Capacitance and inductance tester | tower | 1 | RG-H | |
6 | Grounding continuity tester | tower | 1 | DC:1A | DT-10A |
7 | Transformer DC resistance tester | tower | 2 | DC:≥10A | ZZC-10A |
8 | Transformer ratio tester | tower | 1 | Digital 0.5 level | BBC-H |
9 | Transformer winding deformation tester | tower | 1 | Frequency response method | RBX-H |
10 | Load tap changer tester | tower | 2 | I≥1A | BYKC-3000 |
11 | Circuit breaker characteristic tester | tower | 2 | GKC-H | |
12 | Zinc oxide lightning arrester resistive current tester | tower | 1 |
BLC-H |
|
13 | Three phase relay protection tester | tower | 2 | Two sets of three-phase voltage and current each | HY331 |
14 | Transmission line parameter tester | tower | 1 | Frequency difference method | XLY-Y |
15 | Lightning strike counter calibrator | tower | 1 | FD-III | |
16 | insulation resistance tester | tower | 2 | DC: 0~10000V 200G (Ω), short-circuit current ≥ 5mA |
GM-10kV |
three | Oil and gas experimental instruments | ||||
1 | SF6 leak detector | tower | 1 | Sensitivity 1ppmv | XP-1A |
2 | SF6 gas micro water tester | tower | 1 | WS-2 | |
3 | SF6 gas density calibrator | tower | 1 | Accuracy level 0.2, pressure range 0~1.0Mpa |
MD-H |
4 | Insulation oil chromatograph | tower | 1 | YSP-H | |
5 | Insulation oil closed flash point tester | tower | 1 | YBS-H | |
6 | Insulation oil micro water meter | tower | 1 | PPM level | YWS-H |
7 | Insulation oleic acid value tester | tower | 1 | YSZ-H | |
8 | Insulation oil tester | tower | 1 | ||
9 | Automatic dielectric loss measuring instrument for insulating oil | tower | 1 | YJS-H | |
10 | Insulation oil dielectric strength tester | tower | 1 | JYY-HI | |
four | Common Instrument List | ||||
1 | Megger | only | 2 | DC:2500V | DMG2671 |
2 | Megger | only | 2 | DC:500V | DMG2670 |
3 | Digital dual clamp phase voltmeter | only | 2 | Measure current 1mA~5A | SMG2000E |
Note:1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued
2. To learn more about Huayi products, please enter the product center. Service Hotline:
Those who have obtained a second level installation (repair, testing) license for power facilities can undertake the installation of transmission, power supply, and power receiving facilities below 220 kV. The applicant for the second level installation (repair, testing) power facility license shall meet the following conditions:
(1) Having legal personality and a well-established organizational structure;
(2) The registered capital shall not be less than 20 million yuan, and the net assets shall be over 24 million yuan;
(3) Undertook 2 or more of the following projects within 5 years, with qualified engineering quality:
1. 400 kilometers of transmission lines above 220 kV or 500 kilometers of transmission lines above 110 kV;
2. Four substations with voltage levels above 220 kV or six substations with voltage levels above 110 kV;
3. 40 kilometers of cable lines above 220 kV or 80 kilometers of cable lines above 110 kV;
(4) The highest annual engineering settlement income within 3 years is over 60 million yuan;
(5) The technical leader has over 8 years of experience in power facility installation and management, and holds the professional technical qualification of senior engineer or above in the field of power engineering;
(6) Having no less than 120 professional technical personnel and economic management personnel, including no less than 70 engineering and technical personnel; Among engineering and technical personnel, there shall be no less than 30 personnel with intermediate or higher professional technical qualifications in the field of electric power;
(7) Having no less than 10 registered constructors with a second level or higher qualification in the field of electric power or project managers with a second level or higher qualification in the field of electric power;
(8) There shall be no less than 50 registered electricians holding a network operation certificate, including no less than 25 high-voltage electricians;
(9) There shall be no less than 4 budget officers, no less than 15 installation foremen, no less than 2 full-time quality inspectors, and no less than 2 construction contract administrators with the "Certificate of Professional Management Personnel for Construction Enterprises and Institutions";
(10) Having a dedicated safety management organization, with safety engineers holding professional technical qualifications at or above the level of electrical engineering engineer; There shall be no less than 2 full-time safety supervisors;
(11) Having construction machinery and quality inspection equipment that are suitable for the scope of the project that can be undertaken;
(12) Having a sound technical archive management system;
Product Attachment Diagram
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment
-
Huayi Electric Power specializes in the research and development of power installation and testing equipment