Second hand Agilent liquid chromatograph
Product Introduction of Second hand Agilent Liquid Chromatography System: It has flexible and versatile combination methods; System performance indica
Product details

The second-hand Agilent liquid chromatograph has flexible and versatile combination methods; System performance indicators; A graphical workstation friendly interface; The intelligent maintenance system and improved regulatory certification functions, as well as the continuous introduction of new components, enhance the analytical field of Agilent liquid chromatography.

The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)

0.001-2.5m/min (EFC closed state)

High pressure preparation pump system, unit or dual high-pressure preparation pump

Flow rate range: 0.001-100m1/min

● Flow rate range of analytical pump system:

Unit pump: 0.001-10m3/min, binary pump: 0.001-5m3/min, quaternary pump: 0.001-10m3/min

Used Agilent liquid chromatography 1100 series configuration

1100 series injection system

Standard manual sampler (analytical or preparation type)

● Standard automatic sampler

Sample bottle capacity: up to 100 pieces (2mlx100)

Injection volume: 0.1-100ul (0.1-1800ul) optional

● Micro disc automatic sampler

Sample bottle capacity: 2 × 96 (orifice plate), 2 × 386 (orifice plate) or 100x2ml

Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional

● Micro standard automatic sampler/micro disc automatic sampler

Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)

● Constant temperature standard automatic sampler/micro disc automatic sampler

Temperature range: 4-40 ℃ with adjustable step size of 1 ℃

220 type microporous plate automatic sampler - combined chemical sample management system

Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes

Injection volume: 0.1-5ul; 0.1-20ul

Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190? 600nm

● Multi wavelength detector (MWD) wavelength range: 190? 950nm (dual light source)

● Diode Array Detector (DAD)

Wavelength range: 190? 950nm (dual light source)

Fluorescence detector (FID) excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum

Differential Refraction Detector (RID) Temperature Control: Room Temperature+5 ℃ to 55 ℃ Built in Automatic Purging Valve and Automatic Solvent Circulation Valve

Electrochemical detector (ECD)

LC/MS quadrupole mass detector (MSD)

LC/MS ion trap mass detector (Trap MSD)

Column temperature box and deaerator components

● Column temperature range: 10 ℃ to 80 ℃ at room temperature Optional: Column switching valve

Vacuum online deaerator