Introduction to the device:
The Agilent 1200 series rapid high separation liquid chromatography system has flexible system configuration and can use binary, ternary, and quaternary gradient high-performance liquid chromatography systems. Under the premise of unchanged resolution, sensitivity, and accuracy, the analysis speed is 20 times faster than conventional high-performance liquid chromatography, and the resolution has been improved by 60%.
Technical parameters:
Agilent1200 Agilent liquid chromatography technical parameters
Convenient use of four solvents for equal gradient or gradient analysis, suitable for rapid method development and rapid preparation of mobile phases, as well as flushing HPLC systems
Wide flow range, high flow rate of 10 mL/min, delay volume of 800-1100? L, Suitable for micro diameter columns, standard columns, and semi prepared applications
Programming and control can be easily achieved through the Instant Pilot component, Agilent Chemical Workstation, or EZChrom software
Contains a micro vacuum degassing machine with high degassing efficiency, achieving barrier free operation and performance without the need for helium gas supply
Quickly replace maintenance components directly from the front panel
Quickly identify issues through self diagnosis, built-in logs, and pre programmed testing methods
Early Maintenance Feedback (EMF) continuously monitors instrument usage and user preset limits, and provides feedback information once the limits are exceeded
Upgradeable and expandable within the range of all Agilent 1200 series HPLC components
Main features
1. The Agilent 1200 series quaternary pump is suitable for method development, research, and various applications that require continuous and extensive solvent selection. It has flexibility in solvent selection and automation.
2. The Agilent 1200 quaternary system can quickly switch between methods using different solvents and can use binary, ternary, and quaternary gradients, making it a system on the market.
3. When combined with any Agilent 1200 series automatic sampler, the Agilent 1200 series quaternary system is highly suitable for multi method high-throughput workflows.
4. It is 20 times faster than conventional HPLC and has the same or better data quality (resolution, sensitivity, precision), with a 60% increase in resolution compared to HPLC. Having the same or better data quality (resolution, sensitivity, precision)
5. The delay volume is configurable and suitable for various applications. Can support both narrow diameter columns and standard columns - suitable for RRLC and HPLC
Does not affect the compatibility of existing HPLC methods. Standard delay volume configuration (600-800 µ L), with a column size of 300 mm suitable for supporting LC/MS on narrow diameter columns. Low latency volume configuration (120 µ L)
Regulatory adaptability, meeting regulatory requirements
There are over 70 RRHT columns with a wide range of applicability
A simple, rapid, and reliable method can be used to transfer RRHT and HPLC columns with the same chemical properties of 2000 samples per day from HPLC to RRLC. High throughput configuration, achieved through alternating column regeneration (ACR), the system includes 2 pumps, 2 chromatography columns, and a 2Ps/10Pt valve for alternating column switching.
6. Basic system
Rapid high separation liquid phase system
Binary liquid phase system
Quaternary liquid phase system
Unit liquid phase system
Purification system
HPLC-Chip/MS system
Flow liquid phase system
Capillary liquid phase system
7. 1200 series detector
Diode array detector SL
Fluorescent column detector
Multi wavelength detector SL
Refractive Index Detector
Variable wavelength detector
Multi wavelength detector SL