1Equipment purposeInstructions
Salt spray test is a specialized method for testing the corrosion resistance of products made from surfaces of various materials after anti-corrosion treatments such as paint, coatings, electroplating, anodizing, and rust proof oil.
2、 Widely applicable to industries such as hardware, electroplating, electronics, chemical, automotive, aviation, aerospace, and communication, conducting corrosion tests on product materials and coatings in simulated marine environments to analyze and evaluate the performance of test specimens under specific environmental conditions.
|
Note: This machine requires air pressure:2kgf/cm2(Your factory provides) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
execution standard GB/T 10125-1997Artificial atmosphere corrosion test, salt spray test GB/T 10587-2006Technical conditions for salt spray test chamber GB/T 10593.2-1990Measurement methods for environmental parameters of electrical and electronic products - Salt spray GB/T 12085.4-1989Optics and optical instruments - Environmental test methods - Salt spray GB/T 12967.3-1991Copper accelerated acetate salt spray test for anodic oxidation film of aluminum and aluminum alloys(CASSexperiment) GB/T 1771-1991Determination of neutral salt spray resistance of paints and varnishes GB/T 2423.17-1993Basic Environmental Testing Procedures for Electrical and Electronic Products - TestingKa:Salt spray test method GB/T 5170.8-1996Basic parameter calibration method for environmental testing equipment of electrical and electronic products Salt spray testing equipment QB-T3826-1999Corrosion resistance test method for metal coatings and chemical treatment layers of light industrial products - Neutral salt spray test(NSS)law QB-T3827-1999Corrosion resistance test method for metal coatings and chemical treatment layers of light industrial products - Acetic acid salt spray test(ASS)law QB-T3828-1999Corrosion resistance test method for metal coatings and chemical treatment layers of light industrial products - Copper salt accelerated acetic acid salt spray test(CASS)law International Standard ISO1456/3768/3770; IEC682-11; ASTM B117/B287; CNS3627; MIL. STD202E-101D/810C-509; DIN40046/50021; JISD-0201/H-8681/BS1224/3900
twoTechnical parameters: 1. Laboratory temperature range:+35 ℃ to+50 ℃ 3. Saturation bucket temperature: 47 ℃ -63 ℃
Salt water temperature:+35 ℃~+55 ℃ (matching laboratory temperature) 9.Salt spray depositionquantity:1 ~ 2ml/80cm2/h 10. spray method:Pneumatic type.period.continuous.Fully automatic selection.
11.Mist removal method: Mist is expelled through air compression 13.Precision Glass Nozzle (PYREX)4000 hours guarantee no crystal blockage. working environment Environmental conditions for use:
1. Operating environment temperature: 10 ℃~35 ℃ Model:JK-60CH Product name: saline spray testing machine Specification Description: Inner box size:600*450400mm (L*W*H) Outer box dimensions:1100*800*980mm (L*W*H) power supply220Vsingle-phase1.8KW 50HZ three、Box material 1shell
1Box shell material: 5mm PVC reinforced hard plastic board, with a smooth and even surface, and resistant to aging and corrosion;
The body is made of watersealed structure,Ensure that salt spray does not overflow. 6 The carefully designed water storage and exchange system ensures the smooth operation of the waterway. 7Temperature sensor: corrosion-resistant platinum resistance PT100 Ω/MV. 8Salt liquid collection: A funnel with an area of 80CM ² and a standard measuring cylinder that meet national standards. fourTechnical Basis Operate and set according to JIS, ASTM, CNS, and GB standard parameters. 1. Salt water spray test; NSS 、 ACSS。 Laboratory: 35 ℃± 1 ℃. Pressure air tank: 47 ℃± 1 ℃.
2. Corrosion resistance test: CASS. Laboratory: 50 ℃± 1 ℃. Pressure air tank: 63 ℃± 1 ℃. fiveAir supply system Air supply system: Air pressure is 1Kg/cm2Adjust in two sections. A section for a rough adjustment of 2Kg/cm2Adopting imported technology Air filter with drainage function. The second stage requires precise adjustment of 1Kg/cm2,1/4 Pressure gauge, displaying precision and accuracy.
VIworking principle 1. Bernoulli's principle involves absorbing saltwater and then atomizing it uniformly. By installing a saltwater filter, there is no blockage or crystallization, Can ensure continuous testing. Due to the preheating and temperature control of the saltwater before the experiment, it can ensure more accurate test results. 2. The nozzle is made of tempered glass, which can adjust the spray amount and spray anglePrecision Crystal Glass Mouth (PYREX) 10000 hours guarantee no crystal blockage. 3. The spray amount is 1~2ml/h adjustable (ml/80cm2/h standard requires the average amount after 16 hours of testing). The measuring cylinder adopts an internal design Embedded installation, beautiful and neat appearance, easy operation and observation, reducing instrument installation space. sevenHeating system: plusThe thermal element adoptspureTitanium heating tube,Its corrosion resistance is the same as that of stainless steel heating pipes8 to 10 times or more, Steam directly enters the laboratory, with a fast heating rate and reduced standby time,Automatic switching to constant temperature state, precise temperature, low power consumption,Acid and alkali corrosion resistance, service life.
2. Saturation bucket: usingSUS304Stainless steel has good resistance to high temperature and high pressure.(Image of pressure bucket)
4. Laboratory sample rack:VType bracket0The suspension brackets are all made offiberglassThe rod has corrosion resistance and load-bearing capacity, and can be placed with a large number of test specimens and freely selected according to requirements (placing test plates) eighty percent、Using water quality: (1). Preparation of test solution - distilled water (pure water) (with an HP value between 6.5 and 7.2) (2). Other water use - tap water 4. Air pressure setting (1). Spray pressure -1.0 ± 0.1kgf/cm2 (2). Air compressor pressure regulating filter -2.0~2.5kgf/cm 5. Installed at the edge of the window, it is beneficial for exhaust and drainage NineVulnerable parts: salt spray nozzle, measuring cylinder(保修半年) (For)Ensure the standard of testing quality, every use4000Please replace it regularly within hoursglassGlass nozzle) TenConsumables: Sodium chloride, purified water, tap water tenone、Standard installation equipment 1: 1 set of V-shaped/O-type storage rack 2: 1 measuring cylinder 3: 1 collector 4: 1 glass nozzle 5: 1 saltwater filter 6: Spray tower 1 set
Attachment: Sodium chloride test drug 2Bottle(500gram/Bottle) Operation Manual 1copy Plastic protectionRust bucket 1A (5)Lcapacity)
Warranty condition: One year maintenance fee (excluding human and force majeure factors).lifetimemaintain. One delivery pipe. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||