SRS-PRI photochemical reflectance index measuring instrumentLong term positioning monitoring of plant canopy photochemical reflectance index (PRI) near the ground is an ideal method for studying the lutein cycle at the plant canopy level. SRS-PRI is made with exquisite craftsmanship, sturdy and durable, and can work normally in various harsh weather conditions; It is compact in size and easy to install; High cost-effectiveness, suitable for multiple locations.

working principle
The photochemical reflectance index (PRI) is calculated by adding the difference between the reflectance of the canopy at 532nm and 570nm to the sum of the two. Therefore, both upward and downward sensors need to be installed simultaneously to calculate the reflectance of the canopy at these two wavelengths.
The upward SRS-PRI sensor detects light intensities at 532nm and 570nm. The measurement results represent the intensity of incident light from the sky. The sensor has undergone cosine correction and has a hemispherical field of view. During installation, it is necessary to ensure that there is only the sky within the field of view, without any canopy or other features.
The downward SRS-PRI sensor also detects light intensities at 532nm and 570nm. The measurement results represent the intensity of reflected light from the canopy. The field of view of the sensor is limited to within 36 °, which allows the sensor to accurately face the measured canopy.
Product Features
Low power consumption
cost-effective
Supports SDI-12 or DDI serial communication protocol
Automatic measurement and data collection
Marine grade epoxy resin sealing process, suitable for long-term use in humid and hot environments
If ZL6 data collector is used, remote data viewing and downloading can be realized through Internet terminal
Application field
Study on the utilization efficiency of light energy in plant canopy
Estimate the total primary productivity of the ecosystem
Study the spatial distribution of carbon flux
Study canopy drought, disease, or other stresses
Technical Specifications
| PRIband | Peak wavelengths: 532 ± 2nm and 570 ± 2nm, with a full width at half maximum (FWHM) of 10nm |
| accuracy | 10% better than spectral irradiance and radiance values |
| Electronic optical components | (1) Teflon cosine corrector, hemispherical field of view (2) Field of view aperture: Field of view range of 36 ° |
| calibration | Compliant with the NIST traceable spectral irradiance standard (W m)-2nm-1)Or radiance (W m)-2nm-1sr-1) |
| measure time | ~600 ms |
| size | 43×40×27mm |
| weight | Sensor: 47g, sensor with 5m wire: 170g |
| power supply | 3.6 ~ 15 VDC, 4 mA during measurement period (300ms), 30 µ A during waiting period |
| Operating Temperature | -40~50℃ |
| Cable length | Standard 5 meters, customizable for other lengths |
| interface type | 3.5mm headphone jack or tin plated bare wire jack |
| communication | SDI-12 Digital Sensor |
| Support data collection | METER ZL6, Em50 series, EM60 series data acquisition, ZSC, ProCheck. CSI data acquisition |
Ordering Guide
sensorSRS-PRI upward hemisphere field of view sensor, SRS-PRI downward field of view aperture sensor
data acquisitionZL6 data collector.
Optional accessories
Extension arm1m long aluminum tube, can assist in fixing sensors to infrastructure, can connect most square or circular positions and pipes with a diameter of 2 inches or less
Multi sensor fixed bracketMultiple sensors can be fixed on a bracket. It is recommended to have one upward sensor and no more than three downward sensors, with the downward sensor installed at a 90 ° angle

There are also options available for purchase.
Origin and Manufacturer:the United StatesMETERCompany(Former Decagon)