SP-7890 PDIHID helium ion gas chromatograph
1、 Key parts with blowdown protection valve: positive pressure protection/super seal/special material PDHID detector: American award-winning product/P
Product details

1、 Key parts

Equipped with blow protection valve: positive pressure protection/super seal/special material

PDHIDDetector: American award-winning product/PDPID, PDECD mode

Gas Purifier: PDHID specific/for 99.999% high-purity helium, purifying impurities ≤ 10ppb/long service life.

twoInstrument features:

① Provide a one-stop service for installation, debugging, and operation, with good reliability and long barrier free running time.

② There are two types of pneumatic control, manual and EPC, which are easy to use and have the function of network transmission, unmanned completion, statistical analysis and monitoring.

③ We have adopted VICI's original imported PDHID detector, which won the Analytical Instrument Award that year and has been widely promoted and applied over the years.

④ When analyzing samples containing sulfur-containing components, the instrument used is SilcoTek from the United States ® The silicon passivation treatment process ensures the accuracy of the analysis.

⑤ In order to prevent cross contamination between the sample and the atmosphere or the escape of toxic samples during injection, a special protective sleeve injection valve is used.

⑥ The injection valve, switching valve, and gas system used in the instrument are all imported from VICI company.

⑦ In order to obtain the optimal minimum detection amount, the instrument thoroughly and targetedly purified the carrier gas high-purity helium, using an HP2 gas purifier.

3、 High purityH2analysis report

Analysis conditions: Helium carrier gas pressure:0.46Mpa

Temperature:

Small pillar box1: 65℃

Small pillar box2: 72

Column box: 55

Detector: 150

Injection volume:1ml

鲁南瑞虹分析仪器


Serial Number Retention time name Concentration(ppm peak area


1 1.999 O2 1.89 1495609

2 3.374 N2 1.94 2343692

3 5.074 CH4 2.05 2122156

4 6.837 CO2 2.02 1388244

5 9.786 CO 2.01 920476

───────────────────────

total 9.91 8270177

Components

1

2

3

4

5

6


average value

standard deviation

RSD(%)

O2

1.88

1.89

1.858

1.826

1.861

1.891


1.867666667

0.024776333

1.326592868

N2

1.954

1.94

1.984

1.861

1.914

2.008


1.9435

0.052152661

2.683440212

CH4

2.12

2.05

2.079

2.095

2.045

2.048


2.072833333

0.03055105

1.473878757

CO2

1.975

2.02

1.969

1.985

1.984

1.988


1.986833333

0.017724747

0.892110425

CO

2.16

2.01

2.132

2.052

2.066

2.063


2.0805

0.055265722

2.656367303

Reproducibility: